Cargando…

Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles

BACKGROUND: Biopsy needles have recently been developed to obtain both cytological and histological specimens during endoscopic ultrasound (EUS). We conducted this study to compare 22-gauge (G) fine needle aspiration (FNA) needles, which have been the most frequently used, and new 25G fine needle bi...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Min Jae, Yim, Hyunee, Hwang, Jae Chul, Lee, Dakeun, Kim, Young Bae, Lim, Sun Gyo, Kim, Soon Sun, Kang, Joon Koo, Yoo, Byung Moo, Kim, Jin Hong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4589185/
https://www.ncbi.nlm.nih.gov/pubmed/26419845
http://dx.doi.org/10.1186/s12876-015-0352-9
_version_ 1782392755717144576
author Yang, Min Jae
Yim, Hyunee
Hwang, Jae Chul
Lee, Dakeun
Kim, Young Bae
Lim, Sun Gyo
Kim, Soon Sun
Kang, Joon Koo
Yoo, Byung Moo
Kim, Jin Hong
author_facet Yang, Min Jae
Yim, Hyunee
Hwang, Jae Chul
Lee, Dakeun
Kim, Young Bae
Lim, Sun Gyo
Kim, Soon Sun
Kang, Joon Koo
Yoo, Byung Moo
Kim, Jin Hong
author_sort Yang, Min Jae
collection PubMed
description BACKGROUND: Biopsy needles have recently been developed to obtain both cytological and histological specimens during endoscopic ultrasound (EUS). We conducted this study to compare 22-gauge (G) fine needle aspiration (FNA) needles, which have been the most frequently used, and new 25G fine needle biopsy (FNB) needles for EUS-guided sampling of solid pancreatic masses. METHODS: We conducted a retrospective cohort study of all EUS-guided sampling performed between June 2010 and October 2013. During the study period, 76 patients with pancreatic masses underwent EUS-guided sampling with a 22G FNA needle (n = 38) or a 25G FNB needle (n = 38) for diagnosis. An on-site cytopathologist was not present during the procedure. Technical success, the number of needle passes, cytological diagnostic accuracy, cytological sample quality (conventional smear and liquid-based preparation), histological diagnostic accuracy, and complications were reviewed and compared. RESULTS: There were no significant differences in technical success (100 % for both), the mean number of needle passes (5.05 vs. 5.55, P = 0.132), or complications (0 % for both) between the 22G FNA group and the 25G FNB group. The 22G FNA and 25G FNB groups exhibited comparable outcomes with respect to cytological diagnostic accuracy (97.4 % vs. 89.5 %, P = 0.358) and histological diagnostic accuracy (34.2 % vs. 52.6 %, P = 0.105). In the cytological sample quality analysis, the 25G FNB group exhibited higher scores for the amount of diagnostic cellular material present (22G FNA: 0.92 vs. 25G FNB: 1.32, P = 0.030) and the retention of appropriate architecture (22G FNA: 0.97 vs. 25G FNB: 1.42, P = 0.010) in the liquid-based preparation. The 25G FNB group showed a better histological diagnostic yield for specific tumor discrimination compared with the 22G FNA group (60 % vs. 32.4 %, P = 0.018). CONCLUSIONS: Use of the 25G FNB needle was technically feasible, safe, efficient, and comparable to use of the standard 22G FNA needle in patients with solid pancreatic masses in the absence of an on-site cytopathologist. The cytological sample quality in the liquid-based preparation and the histological diagnostic yield for specific tumor discrimination of EUS-guided sampling using a 25G FNB needle were significantly higher than those using a 22G FNA needle.
format Online
Article
Text
id pubmed-4589185
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-45891852015-10-01 Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles Yang, Min Jae Yim, Hyunee Hwang, Jae Chul Lee, Dakeun Kim, Young Bae Lim, Sun Gyo Kim, Soon Sun Kang, Joon Koo Yoo, Byung Moo Kim, Jin Hong BMC Gastroenterol Research Article BACKGROUND: Biopsy needles have recently been developed to obtain both cytological and histological specimens during endoscopic ultrasound (EUS). We conducted this study to compare 22-gauge (G) fine needle aspiration (FNA) needles, which have been the most frequently used, and new 25G fine needle biopsy (FNB) needles for EUS-guided sampling of solid pancreatic masses. METHODS: We conducted a retrospective cohort study of all EUS-guided sampling performed between June 2010 and October 2013. During the study period, 76 patients with pancreatic masses underwent EUS-guided sampling with a 22G FNA needle (n = 38) or a 25G FNB needle (n = 38) for diagnosis. An on-site cytopathologist was not present during the procedure. Technical success, the number of needle passes, cytological diagnostic accuracy, cytological sample quality (conventional smear and liquid-based preparation), histological diagnostic accuracy, and complications were reviewed and compared. RESULTS: There were no significant differences in technical success (100 % for both), the mean number of needle passes (5.05 vs. 5.55, P = 0.132), or complications (0 % for both) between the 22G FNA group and the 25G FNB group. The 22G FNA and 25G FNB groups exhibited comparable outcomes with respect to cytological diagnostic accuracy (97.4 % vs. 89.5 %, P = 0.358) and histological diagnostic accuracy (34.2 % vs. 52.6 %, P = 0.105). In the cytological sample quality analysis, the 25G FNB group exhibited higher scores for the amount of diagnostic cellular material present (22G FNA: 0.92 vs. 25G FNB: 1.32, P = 0.030) and the retention of appropriate architecture (22G FNA: 0.97 vs. 25G FNB: 1.42, P = 0.010) in the liquid-based preparation. The 25G FNB group showed a better histological diagnostic yield for specific tumor discrimination compared with the 22G FNA group (60 % vs. 32.4 %, P = 0.018). CONCLUSIONS: Use of the 25G FNB needle was technically feasible, safe, efficient, and comparable to use of the standard 22G FNA needle in patients with solid pancreatic masses in the absence of an on-site cytopathologist. The cytological sample quality in the liquid-based preparation and the histological diagnostic yield for specific tumor discrimination of EUS-guided sampling using a 25G FNB needle were significantly higher than those using a 22G FNA needle. BioMed Central 2015-09-29 /pmc/articles/PMC4589185/ /pubmed/26419845 http://dx.doi.org/10.1186/s12876-015-0352-9 Text en © Yang et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Yang, Min Jae
Yim, Hyunee
Hwang, Jae Chul
Lee, Dakeun
Kim, Young Bae
Lim, Sun Gyo
Kim, Soon Sun
Kang, Joon Koo
Yoo, Byung Moo
Kim, Jin Hong
Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles
title Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles
title_full Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles
title_fullStr Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles
title_full_unstemmed Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles
title_short Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles
title_sort endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4589185/
https://www.ncbi.nlm.nih.gov/pubmed/26419845
http://dx.doi.org/10.1186/s12876-015-0352-9
work_keys_str_mv AT yangminjae endoscopicultrasoundguidedsamplingofsolidpancreaticmasses22gaugeaspirationversus25gaugebiopsyneedles
AT yimhyunee endoscopicultrasoundguidedsamplingofsolidpancreaticmasses22gaugeaspirationversus25gaugebiopsyneedles
AT hwangjaechul endoscopicultrasoundguidedsamplingofsolidpancreaticmasses22gaugeaspirationversus25gaugebiopsyneedles
AT leedakeun endoscopicultrasoundguidedsamplingofsolidpancreaticmasses22gaugeaspirationversus25gaugebiopsyneedles
AT kimyoungbae endoscopicultrasoundguidedsamplingofsolidpancreaticmasses22gaugeaspirationversus25gaugebiopsyneedles
AT limsungyo endoscopicultrasoundguidedsamplingofsolidpancreaticmasses22gaugeaspirationversus25gaugebiopsyneedles
AT kimsoonsun endoscopicultrasoundguidedsamplingofsolidpancreaticmasses22gaugeaspirationversus25gaugebiopsyneedles
AT kangjoonkoo endoscopicultrasoundguidedsamplingofsolidpancreaticmasses22gaugeaspirationversus25gaugebiopsyneedles
AT yoobyungmoo endoscopicultrasoundguidedsamplingofsolidpancreaticmasses22gaugeaspirationversus25gaugebiopsyneedles
AT kimjinhong endoscopicultrasoundguidedsamplingofsolidpancreaticmasses22gaugeaspirationversus25gaugebiopsyneedles