Cargando…

A Simple “Blood-Saving Bundle” Reduces Diagnostic Blood Loss and the Transfusion Rate in Mechanically Ventilated Patients

INTRODUCTION: Aim of this study was to reduce blood loss caused by diagnostic blood sampling and to minimize the development of anemia in a high-risk group of mechanically ventilated medical intensive care patients. We therefore implemented a “blood-saving bundle” (BSB) combining a closed-loop arter...

Descripción completa

Detalles Bibliográficos
Autores principales: Riessen, Reimer, Behmenburg, Melanie, Blumenstock, Gunnar, Guenon, Doris, Enkel, Sigrid, Schäfer, Richard, Haap, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4589283/
https://www.ncbi.nlm.nih.gov/pubmed/26421920
http://dx.doi.org/10.1371/journal.pone.0138879
_version_ 1782392764440248320
author Riessen, Reimer
Behmenburg, Melanie
Blumenstock, Gunnar
Guenon, Doris
Enkel, Sigrid
Schäfer, Richard
Haap, Michael
author_facet Riessen, Reimer
Behmenburg, Melanie
Blumenstock, Gunnar
Guenon, Doris
Enkel, Sigrid
Schäfer, Richard
Haap, Michael
author_sort Riessen, Reimer
collection PubMed
description INTRODUCTION: Aim of this study was to reduce blood loss caused by diagnostic blood sampling and to minimize the development of anemia in a high-risk group of mechanically ventilated medical intensive care patients. We therefore implemented a “blood-saving bundle” (BSB) combining a closed-loop arterial blood sampling system, smaller sampling tubes, reduced frequency of blood drawings, and reduced sample numbers. METHODS: The study included all patients from our medical ICU who were ventilated for more than 72 hours. Exclusion criteria were: acute or chronic anemia on admission, bleeding episode(s) during the ICU stay, or end-of-life therapy. The BSB was introduced in 2009 with training and educational support. Patients treated in 2008, before the introduction of the BSB, served as a control group (n = 41, 617 observation days), and were compared with patients treated in 2010 after the introduction of the BSB (BSB group, n = 50, 559 observation days). Primary endpoints were blood loss per day, and development of anemia. Secondary endpoints were numbers of blood transfusions, number of days on mechanical ventilation, and length of the ICU stay. RESULTS: Mean blood loss per ICU day was decreased from 43.3 ml (95% CI: 41.2 to 45.3 ml) in the controls to 15.0 ml (14.3 to 15.7 ml) in the BSB group (P < 0.001). The introduction of a closed-loop arterial blood sampling system was the major contributor to this effect. Mean hemoglobin concentrations showed no significant differences in both groups during the ICU stay. Hemoglobin values <9 g/dl, however, were recorded in 21.2% of observation days in the controls versus 15.4% in the BSB group (P = 0.01). Units of transfused red blood cells per 100 observation days decreased from 7 to 2.3 (P < 0.001). The mean number of ventilation days was 7.1 days (6.1 to 8.3 days) in the controls and 7.5 days (6.6 to 8.5 days) in the BSB group (P = NS). In total, patients in the BSB group stayed in ICU for a mean of 9.9 days (8.6 to 11.3 days), compared to a mean ICU stay of 13.0 days (10.9 to 15.4 days) in the control group (P = 0.014). Due to the longitudinal study design, however, we cannot exclude uncontrolled confounders affecting the transfusion frequency and mean ICU stay. CONCLUSION: Our BSB could be easily implemented and was able to reduce diagnostic blood loss.
format Online
Article
Text
id pubmed-4589283
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45892832015-10-02 A Simple “Blood-Saving Bundle” Reduces Diagnostic Blood Loss and the Transfusion Rate in Mechanically Ventilated Patients Riessen, Reimer Behmenburg, Melanie Blumenstock, Gunnar Guenon, Doris Enkel, Sigrid Schäfer, Richard Haap, Michael PLoS One Research Article INTRODUCTION: Aim of this study was to reduce blood loss caused by diagnostic blood sampling and to minimize the development of anemia in a high-risk group of mechanically ventilated medical intensive care patients. We therefore implemented a “blood-saving bundle” (BSB) combining a closed-loop arterial blood sampling system, smaller sampling tubes, reduced frequency of blood drawings, and reduced sample numbers. METHODS: The study included all patients from our medical ICU who were ventilated for more than 72 hours. Exclusion criteria were: acute or chronic anemia on admission, bleeding episode(s) during the ICU stay, or end-of-life therapy. The BSB was introduced in 2009 with training and educational support. Patients treated in 2008, before the introduction of the BSB, served as a control group (n = 41, 617 observation days), and were compared with patients treated in 2010 after the introduction of the BSB (BSB group, n = 50, 559 observation days). Primary endpoints were blood loss per day, and development of anemia. Secondary endpoints were numbers of blood transfusions, number of days on mechanical ventilation, and length of the ICU stay. RESULTS: Mean blood loss per ICU day was decreased from 43.3 ml (95% CI: 41.2 to 45.3 ml) in the controls to 15.0 ml (14.3 to 15.7 ml) in the BSB group (P < 0.001). The introduction of a closed-loop arterial blood sampling system was the major contributor to this effect. Mean hemoglobin concentrations showed no significant differences in both groups during the ICU stay. Hemoglobin values <9 g/dl, however, were recorded in 21.2% of observation days in the controls versus 15.4% in the BSB group (P = 0.01). Units of transfused red blood cells per 100 observation days decreased from 7 to 2.3 (P < 0.001). The mean number of ventilation days was 7.1 days (6.1 to 8.3 days) in the controls and 7.5 days (6.6 to 8.5 days) in the BSB group (P = NS). In total, patients in the BSB group stayed in ICU for a mean of 9.9 days (8.6 to 11.3 days), compared to a mean ICU stay of 13.0 days (10.9 to 15.4 days) in the control group (P = 0.014). Due to the longitudinal study design, however, we cannot exclude uncontrolled confounders affecting the transfusion frequency and mean ICU stay. CONCLUSION: Our BSB could be easily implemented and was able to reduce diagnostic blood loss. Public Library of Science 2015-09-30 /pmc/articles/PMC4589283/ /pubmed/26421920 http://dx.doi.org/10.1371/journal.pone.0138879 Text en © 2015 Riessen et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Riessen, Reimer
Behmenburg, Melanie
Blumenstock, Gunnar
Guenon, Doris
Enkel, Sigrid
Schäfer, Richard
Haap, Michael
A Simple “Blood-Saving Bundle” Reduces Diagnostic Blood Loss and the Transfusion Rate in Mechanically Ventilated Patients
title A Simple “Blood-Saving Bundle” Reduces Diagnostic Blood Loss and the Transfusion Rate in Mechanically Ventilated Patients
title_full A Simple “Blood-Saving Bundle” Reduces Diagnostic Blood Loss and the Transfusion Rate in Mechanically Ventilated Patients
title_fullStr A Simple “Blood-Saving Bundle” Reduces Diagnostic Blood Loss and the Transfusion Rate in Mechanically Ventilated Patients
title_full_unstemmed A Simple “Blood-Saving Bundle” Reduces Diagnostic Blood Loss and the Transfusion Rate in Mechanically Ventilated Patients
title_short A Simple “Blood-Saving Bundle” Reduces Diagnostic Blood Loss and the Transfusion Rate in Mechanically Ventilated Patients
title_sort simple “blood-saving bundle” reduces diagnostic blood loss and the transfusion rate in mechanically ventilated patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4589283/
https://www.ncbi.nlm.nih.gov/pubmed/26421920
http://dx.doi.org/10.1371/journal.pone.0138879
work_keys_str_mv AT riessenreimer asimplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT behmenburgmelanie asimplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT blumenstockgunnar asimplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT guenondoris asimplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT enkelsigrid asimplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT schaferrichard asimplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT haapmichael asimplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT riessenreimer simplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT behmenburgmelanie simplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT blumenstockgunnar simplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT guenondoris simplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT enkelsigrid simplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT schaferrichard simplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients
AT haapmichael simplebloodsavingbundlereducesdiagnosticbloodlossandthetransfusionrateinmechanicallyventilatedpatients