Cargando…
Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study
BACKGROUND: Fixed orthodontic mechanotherapy is associated with friction between the bracket - wire - ligature interfaces during the sliding mechanics. A sound knowledge of the various factors affecting the magnitude of friction is of paramount importance. The present study was done to analyze and c...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dentmedpub Research and Printing Co
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4589702/ https://www.ncbi.nlm.nih.gov/pubmed/26435628 |
_version_ | 1782392830768971776 |
---|---|
author | Pasha, Azam Vishwakarma, Swati Narayan, Anjali Vinay, K Shetty, Smitha V Roy, Partha Pratim |
author_facet | Pasha, Azam Vishwakarma, Swati Narayan, Anjali Vinay, K Shetty, Smitha V Roy, Partha Pratim |
author_sort | Pasha, Azam |
collection | PubMed |
description | BACKGROUND: Fixed orthodontic mechanotherapy is associated with friction between the bracket - wire - ligature interfaces during the sliding mechanics. A sound knowledge of the various factors affecting the magnitude of friction is of paramount importance. The present study was done to analyze and compare the frictional forces generated by a new ceramic (Clarity Advanced) bracket with the conventional, (metal and ceramic) brackets using unconventional and conventional ligation system, and the self-ligating (metal and ceramic) brackets in the dry condition. MATERIALS AND METHODS: The various bracket wire ligation combinations were tested in dry condition. The brackets used were of 0.022″ × 0.028″ nominal slot dimension of MBT prescription: Stainless steel (SS) self-ligating bracket (SLB) of (SmartClip), SS Conventional bracket (CB) (Victory series), Ceramic SLB (Clarity SL), Conventional Ceramic bracket with metal slot (Clarity Bracket), Clarity Advanced Ceramic Brackets (Clarity(™) ADVANCED, 3M Unitek). These brackets were used with two types of elastomeric ligatures: Conventional Elastomeric Ligatures (CEL) (Clear medium mini modules) and Unconventional Elastomeric Ligatures (UEL) (Clear medium slide ligatures, Leone orthodontic products). The aligning and the retraction wires were used, i.e., 0.014″ nickel titanium (NiTi) wires and 0.019″ × 0.025″ SS wires, respectively. A universal strength testing machine was used to measure the friction produced between the different bracket, archwires, and ligation combination. This was done with the use of a custom-made jig being in position. RESULTS: Mean, standard deviation, and range were computed for the frictional values obtained. Results were subjected to statistical analysis through ANOVA. The frictional resistance observed in the new Clarity Advanced bracket with a conventional elastomeric ligature was almost similar with the Clarity metal slot bracket with a conventional elastomeric ligature. When using the UEL, the Clarity Advanced bracket produced lesser friction than the conventional metal bracket; but not less than the ceramic metal slot bracket. Ceramic SLB produced lesser friction when compared with the Clarity Advanced bracket with UEL, but the metal SLB produced the least friction among all the groups and subgroups. CONCLUSION: The present study concluded that the SS SLB produced least friction among all groups. Using the archwire and ligation method, frictional forces observed in the Clarity Advanced bracket and the conventional ceramic with metal slot bracket were almost similar; but the least resistance was determined in SS CB using both the ligation (CEL and UEL) system. |
format | Online Article Text |
id | pubmed-4589702 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Dentmedpub Research and Printing Co |
record_format | MEDLINE/PubMed |
spelling | pubmed-45897022015-11-01 Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study Pasha, Azam Vishwakarma, Swati Narayan, Anjali Vinay, K Shetty, Smitha V Roy, Partha Pratim J Int Oral Health Original Research BACKGROUND: Fixed orthodontic mechanotherapy is associated with friction between the bracket - wire - ligature interfaces during the sliding mechanics. A sound knowledge of the various factors affecting the magnitude of friction is of paramount importance. The present study was done to analyze and compare the frictional forces generated by a new ceramic (Clarity Advanced) bracket with the conventional, (metal and ceramic) brackets using unconventional and conventional ligation system, and the self-ligating (metal and ceramic) brackets in the dry condition. MATERIALS AND METHODS: The various bracket wire ligation combinations were tested in dry condition. The brackets used were of 0.022″ × 0.028″ nominal slot dimension of MBT prescription: Stainless steel (SS) self-ligating bracket (SLB) of (SmartClip), SS Conventional bracket (CB) (Victory series), Ceramic SLB (Clarity SL), Conventional Ceramic bracket with metal slot (Clarity Bracket), Clarity Advanced Ceramic Brackets (Clarity(™) ADVANCED, 3M Unitek). These brackets were used with two types of elastomeric ligatures: Conventional Elastomeric Ligatures (CEL) (Clear medium mini modules) and Unconventional Elastomeric Ligatures (UEL) (Clear medium slide ligatures, Leone orthodontic products). The aligning and the retraction wires were used, i.e., 0.014″ nickel titanium (NiTi) wires and 0.019″ × 0.025″ SS wires, respectively. A universal strength testing machine was used to measure the friction produced between the different bracket, archwires, and ligation combination. This was done with the use of a custom-made jig being in position. RESULTS: Mean, standard deviation, and range were computed for the frictional values obtained. Results were subjected to statistical analysis through ANOVA. The frictional resistance observed in the new Clarity Advanced bracket with a conventional elastomeric ligature was almost similar with the Clarity metal slot bracket with a conventional elastomeric ligature. When using the UEL, the Clarity Advanced bracket produced lesser friction than the conventional metal bracket; but not less than the ceramic metal slot bracket. Ceramic SLB produced lesser friction when compared with the Clarity Advanced bracket with UEL, but the metal SLB produced the least friction among all the groups and subgroups. CONCLUSION: The present study concluded that the SS SLB produced least friction among all groups. Using the archwire and ligation method, frictional forces observed in the Clarity Advanced bracket and the conventional ceramic with metal slot bracket were almost similar; but the least resistance was determined in SS CB using both the ligation (CEL and UEL) system. Dentmedpub Research and Printing Co 2015-09 /pmc/articles/PMC4589702/ /pubmed/26435628 Text en Copyright: © Journal of International Oral Health http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Research Pasha, Azam Vishwakarma, Swati Narayan, Anjali Vinay, K Shetty, Smitha V Roy, Partha Pratim Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study |
title | Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study |
title_full | Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study |
title_fullStr | Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study |
title_full_unstemmed | Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study |
title_short | Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study |
title_sort | comparison of frictional forces generated by a new ceramic bracket with the conventional brackets using unconventional and conventional ligation system and the self-ligating brackets: an in vitro study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4589702/ https://www.ncbi.nlm.nih.gov/pubmed/26435628 |
work_keys_str_mv | AT pashaazam comparisonoffrictionalforcesgeneratedbyanewceramicbracketwiththeconventionalbracketsusingunconventionalandconventionalligationsystemandtheselfligatingbracketsaninvitrostudy AT vishwakarmaswati comparisonoffrictionalforcesgeneratedbyanewceramicbracketwiththeconventionalbracketsusingunconventionalandconventionalligationsystemandtheselfligatingbracketsaninvitrostudy AT narayananjali comparisonoffrictionalforcesgeneratedbyanewceramicbracketwiththeconventionalbracketsusingunconventionalandconventionalligationsystemandtheselfligatingbracketsaninvitrostudy AT vinayk comparisonoffrictionalforcesgeneratedbyanewceramicbracketwiththeconventionalbracketsusingunconventionalandconventionalligationsystemandtheselfligatingbracketsaninvitrostudy AT shettysmithav comparisonoffrictionalforcesgeneratedbyanewceramicbracketwiththeconventionalbracketsusingunconventionalandconventionalligationsystemandtheselfligatingbracketsaninvitrostudy AT royparthapratim comparisonoffrictionalforcesgeneratedbyanewceramicbracketwiththeconventionalbracketsusingunconventionalandconventionalligationsystemandtheselfligatingbracketsaninvitrostudy |