Cargando…

Treatment Plan Technique and Quality for Single-Isocenter Stereotactic Ablative Radiotherapy of Multiple Lung Lesions with Volumetric-Modulated Arc Therapy or Intensity-Modulated Radiosurgery

The aim of this study is to provide a practical approach to the planning technique and evaluation of plan quality for the multi-lesion, single-isocenter stereotactic ablative radiotherapy (SABR) of the lung. Eleven patients with two or more lung lesions underwent single-isocenter volumetric-modulate...

Descripción completa

Detalles Bibliográficos
Autores principales: Quan, Kimmen, Xu, Karen M., Lalonde, Ron, Horne, Zachary D., Bernard, Mark E., McCoy, Chuck, Clump, David A., Burton, Steven A., Heron, Dwight E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4594030/
https://www.ncbi.nlm.nih.gov/pubmed/26500888
http://dx.doi.org/10.3389/fonc.2015.00213
_version_ 1782393398803562496
author Quan, Kimmen
Xu, Karen M.
Lalonde, Ron
Horne, Zachary D.
Bernard, Mark E.
McCoy, Chuck
Clump, David A.
Burton, Steven A.
Heron, Dwight E.
author_facet Quan, Kimmen
Xu, Karen M.
Lalonde, Ron
Horne, Zachary D.
Bernard, Mark E.
McCoy, Chuck
Clump, David A.
Burton, Steven A.
Heron, Dwight E.
author_sort Quan, Kimmen
collection PubMed
description The aim of this study is to provide a practical approach to the planning technique and evaluation of plan quality for the multi-lesion, single-isocenter stereotactic ablative radiotherapy (SABR) of the lung. Eleven patients with two or more lung lesions underwent single-isocenter volumetric-modulated arc therapy (VMAT) radiosurgery or IMRS. All plans were normalized to the target maximum dose. For each plan, all targets were treated to the same dose. Plan conformity and dose gradient were maximized with dose-control tuning structures surrounding targets. For comparison, multi-isocenter plans were retrospectively created for four patients. Conformity index (CI), homogeneity index (HI), gradient index (GI), and gradient distance (GD) were calculated for each plan. V5, V10, and V20 of the lung and organs at risk (OARs) were collected. Treatment time and total monitor units (MUs) were also recorded. One patient had four lesions and the remainder had two lesions. Six patients received VMAT and five patients received intensity-modulated radiosurgery (IMRS). For those treated with VMAT, two patients received 3-arc VMAT and four received 2-arc VMAT. For those treated with IMRS, two patients were treated with 10 and 11 beams, respectively, and the rest received 12 beams. Prescription doses ranged from 30 to 54 Gy in three to five fractions. The median prescribed isodose line was 84% (range: 80–86%). The median maximum dose was 57.1 Gy (range: 35.7–65.1 Gy). The mean combined PTV was 49.57 cm(3) (range: 14.90–87.38 cm(3)). For single-isocenter plans, the median CI was 1.15 (range: 0.97–1.53). The median HI was 1.19 (range: 1.16–1.28). The median GI was 4.60 (range: 4.16–7.37). The median maximum radiation dose (D(max)) to total lung was 55.6 Gy (range: 35.7–62.0 Gy). The median mean radiation dose to the lung (D(mean)) was 4.2 Gy (range: 1.1–9.3 Gy). The median lung V5 was 18.7% (range: 3.8–41.3%). There was no significant difference in CI, HI, GI, GD, V5, V10, and V20 (lung, heart, trachea, esophagus, and spinal cord) between single-isocenter and multi-isocenter plans. This multi-lesion, single-isocenter lung SABR planning technique demonstrated excellent plan quality and clinical efficiency and is recommended for radiosurgical treatment of two or more lung targets for well-suited patients.
format Online
Article
Text
id pubmed-4594030
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-45940302015-10-23 Treatment Plan Technique and Quality for Single-Isocenter Stereotactic Ablative Radiotherapy of Multiple Lung Lesions with Volumetric-Modulated Arc Therapy or Intensity-Modulated Radiosurgery Quan, Kimmen Xu, Karen M. Lalonde, Ron Horne, Zachary D. Bernard, Mark E. McCoy, Chuck Clump, David A. Burton, Steven A. Heron, Dwight E. Front Oncol Oncology The aim of this study is to provide a practical approach to the planning technique and evaluation of plan quality for the multi-lesion, single-isocenter stereotactic ablative radiotherapy (SABR) of the lung. Eleven patients with two or more lung lesions underwent single-isocenter volumetric-modulated arc therapy (VMAT) radiosurgery or IMRS. All plans were normalized to the target maximum dose. For each plan, all targets were treated to the same dose. Plan conformity and dose gradient were maximized with dose-control tuning structures surrounding targets. For comparison, multi-isocenter plans were retrospectively created for four patients. Conformity index (CI), homogeneity index (HI), gradient index (GI), and gradient distance (GD) were calculated for each plan. V5, V10, and V20 of the lung and organs at risk (OARs) were collected. Treatment time and total monitor units (MUs) were also recorded. One patient had four lesions and the remainder had two lesions. Six patients received VMAT and five patients received intensity-modulated radiosurgery (IMRS). For those treated with VMAT, two patients received 3-arc VMAT and four received 2-arc VMAT. For those treated with IMRS, two patients were treated with 10 and 11 beams, respectively, and the rest received 12 beams. Prescription doses ranged from 30 to 54 Gy in three to five fractions. The median prescribed isodose line was 84% (range: 80–86%). The median maximum dose was 57.1 Gy (range: 35.7–65.1 Gy). The mean combined PTV was 49.57 cm(3) (range: 14.90–87.38 cm(3)). For single-isocenter plans, the median CI was 1.15 (range: 0.97–1.53). The median HI was 1.19 (range: 1.16–1.28). The median GI was 4.60 (range: 4.16–7.37). The median maximum radiation dose (D(max)) to total lung was 55.6 Gy (range: 35.7–62.0 Gy). The median mean radiation dose to the lung (D(mean)) was 4.2 Gy (range: 1.1–9.3 Gy). The median lung V5 was 18.7% (range: 3.8–41.3%). There was no significant difference in CI, HI, GI, GD, V5, V10, and V20 (lung, heart, trachea, esophagus, and spinal cord) between single-isocenter and multi-isocenter plans. This multi-lesion, single-isocenter lung SABR planning technique demonstrated excellent plan quality and clinical efficiency and is recommended for radiosurgical treatment of two or more lung targets for well-suited patients. Frontiers Media S.A. 2015-10-06 /pmc/articles/PMC4594030/ /pubmed/26500888 http://dx.doi.org/10.3389/fonc.2015.00213 Text en Copyright © 2015 Quan, Xu, Lalonde, Horne, Bernard, McCoy, Clump, Burton and Heron. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Quan, Kimmen
Xu, Karen M.
Lalonde, Ron
Horne, Zachary D.
Bernard, Mark E.
McCoy, Chuck
Clump, David A.
Burton, Steven A.
Heron, Dwight E.
Treatment Plan Technique and Quality for Single-Isocenter Stereotactic Ablative Radiotherapy of Multiple Lung Lesions with Volumetric-Modulated Arc Therapy or Intensity-Modulated Radiosurgery
title Treatment Plan Technique and Quality for Single-Isocenter Stereotactic Ablative Radiotherapy of Multiple Lung Lesions with Volumetric-Modulated Arc Therapy or Intensity-Modulated Radiosurgery
title_full Treatment Plan Technique and Quality for Single-Isocenter Stereotactic Ablative Radiotherapy of Multiple Lung Lesions with Volumetric-Modulated Arc Therapy or Intensity-Modulated Radiosurgery
title_fullStr Treatment Plan Technique and Quality for Single-Isocenter Stereotactic Ablative Radiotherapy of Multiple Lung Lesions with Volumetric-Modulated Arc Therapy or Intensity-Modulated Radiosurgery
title_full_unstemmed Treatment Plan Technique and Quality for Single-Isocenter Stereotactic Ablative Radiotherapy of Multiple Lung Lesions with Volumetric-Modulated Arc Therapy or Intensity-Modulated Radiosurgery
title_short Treatment Plan Technique and Quality for Single-Isocenter Stereotactic Ablative Radiotherapy of Multiple Lung Lesions with Volumetric-Modulated Arc Therapy or Intensity-Modulated Radiosurgery
title_sort treatment plan technique and quality for single-isocenter stereotactic ablative radiotherapy of multiple lung lesions with volumetric-modulated arc therapy or intensity-modulated radiosurgery
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4594030/
https://www.ncbi.nlm.nih.gov/pubmed/26500888
http://dx.doi.org/10.3389/fonc.2015.00213
work_keys_str_mv AT quankimmen treatmentplantechniqueandqualityforsingleisocenterstereotacticablativeradiotherapyofmultiplelunglesionswithvolumetricmodulatedarctherapyorintensitymodulatedradiosurgery
AT xukarenm treatmentplantechniqueandqualityforsingleisocenterstereotacticablativeradiotherapyofmultiplelunglesionswithvolumetricmodulatedarctherapyorintensitymodulatedradiosurgery
AT lalonderon treatmentplantechniqueandqualityforsingleisocenterstereotacticablativeradiotherapyofmultiplelunglesionswithvolumetricmodulatedarctherapyorintensitymodulatedradiosurgery
AT hornezacharyd treatmentplantechniqueandqualityforsingleisocenterstereotacticablativeradiotherapyofmultiplelunglesionswithvolumetricmodulatedarctherapyorintensitymodulatedradiosurgery
AT bernardmarke treatmentplantechniqueandqualityforsingleisocenterstereotacticablativeradiotherapyofmultiplelunglesionswithvolumetricmodulatedarctherapyorintensitymodulatedradiosurgery
AT mccoychuck treatmentplantechniqueandqualityforsingleisocenterstereotacticablativeradiotherapyofmultiplelunglesionswithvolumetricmodulatedarctherapyorintensitymodulatedradiosurgery
AT clumpdavida treatmentplantechniqueandqualityforsingleisocenterstereotacticablativeradiotherapyofmultiplelunglesionswithvolumetricmodulatedarctherapyorintensitymodulatedradiosurgery
AT burtonstevena treatmentplantechniqueandqualityforsingleisocenterstereotacticablativeradiotherapyofmultiplelunglesionswithvolumetricmodulatedarctherapyorintensitymodulatedradiosurgery
AT herondwighte treatmentplantechniqueandqualityforsingleisocenterstereotacticablativeradiotherapyofmultiplelunglesionswithvolumetricmodulatedarctherapyorintensitymodulatedradiosurgery