Cargando…
A phantom study on the behavior of Acuros XB algorithm in flattening filter free photon beams
To study the behavior of Acuros XB algorithm for flattening filter free (FFF) photon beams in comparison with the anisotropic analytical algorithm (AAA) when applied to homogeneous and heterogeneous phantoms in conventional and RapidArc techniques. Acuros XB (Eclipse version 10.0, Varian Medical Sys...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4594383/ https://www.ncbi.nlm.nih.gov/pubmed/26500400 http://dx.doi.org/10.4103/0971-6203.165076 |
_version_ | 1782393443273670656 |
---|---|
author | Muralidhar, K. R. Pangam, Suresh Srinivas, P. Athar Ali, Mirza Priya, V. Sujana Komanduri, Krishna |
author_facet | Muralidhar, K. R. Pangam, Suresh Srinivas, P. Athar Ali, Mirza Priya, V. Sujana Komanduri, Krishna |
author_sort | Muralidhar, K. R. |
collection | PubMed |
description | To study the behavior of Acuros XB algorithm for flattening filter free (FFF) photon beams in comparison with the anisotropic analytical algorithm (AAA) when applied to homogeneous and heterogeneous phantoms in conventional and RapidArc techniques. Acuros XB (Eclipse version 10.0, Varian Medical Systems, CA, USA) and AAA algorithms were used to calculate dose distributions for both 6X FFF and 10X FFF energies. RapidArc plans were created on Catphan phantom 504 and conventional plans on virtual homogeneous water phantom 30 × 30 × 30 cm(3), virtual heterogeneous phantom with various inserts and on solid water phantom with air cavity. Dose at various inserts with different densities were measured in both AAA and Acuros algorithms. The maximum % variation in dose was observed in (−944 HU) air insert and minimum in (85 HU) acrylic insert in both 6X FFF and 10X FFF photons. Less than 1% variation observed between −149 HU and 282 HU for both energies. At −40 HU and 765 HU Acuros behaved quite contrarily with 10X FFF. Maximum % variation in dose was observed in less HU values and minimum variation in higher HU values for both FFF energies. Global maximum dose observed at higher depths for Acuros for both energies compared with AAA. Increase in dose was observed with Acuros algorithm in almost all densities and decrease at few densities ranging from 282 to 643 HU values. Field size, depth, beam energy, and material density influenced the dose difference between two algorithms. |
format | Online Article Text |
id | pubmed-4594383 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-45943832015-10-23 A phantom study on the behavior of Acuros XB algorithm in flattening filter free photon beams Muralidhar, K. R. Pangam, Suresh Srinivas, P. Athar Ali, Mirza Priya, V. Sujana Komanduri, Krishna J Med Phys Original Article To study the behavior of Acuros XB algorithm for flattening filter free (FFF) photon beams in comparison with the anisotropic analytical algorithm (AAA) when applied to homogeneous and heterogeneous phantoms in conventional and RapidArc techniques. Acuros XB (Eclipse version 10.0, Varian Medical Systems, CA, USA) and AAA algorithms were used to calculate dose distributions for both 6X FFF and 10X FFF energies. RapidArc plans were created on Catphan phantom 504 and conventional plans on virtual homogeneous water phantom 30 × 30 × 30 cm(3), virtual heterogeneous phantom with various inserts and on solid water phantom with air cavity. Dose at various inserts with different densities were measured in both AAA and Acuros algorithms. The maximum % variation in dose was observed in (−944 HU) air insert and minimum in (85 HU) acrylic insert in both 6X FFF and 10X FFF photons. Less than 1% variation observed between −149 HU and 282 HU for both energies. At −40 HU and 765 HU Acuros behaved quite contrarily with 10X FFF. Maximum % variation in dose was observed in less HU values and minimum variation in higher HU values for both FFF energies. Global maximum dose observed at higher depths for Acuros for both energies compared with AAA. Increase in dose was observed with Acuros algorithm in almost all densities and decrease at few densities ranging from 282 to 643 HU values. Field size, depth, beam energy, and material density influenced the dose difference between two algorithms. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4594383/ /pubmed/26500400 http://dx.doi.org/10.4103/0971-6203.165076 Text en Copyright: © 2015 Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Muralidhar, K. R. Pangam, Suresh Srinivas, P. Athar Ali, Mirza Priya, V. Sujana Komanduri, Krishna A phantom study on the behavior of Acuros XB algorithm in flattening filter free photon beams |
title | A phantom study on the behavior of Acuros XB algorithm in flattening filter free photon beams |
title_full | A phantom study on the behavior of Acuros XB algorithm in flattening filter free photon beams |
title_fullStr | A phantom study on the behavior of Acuros XB algorithm in flattening filter free photon beams |
title_full_unstemmed | A phantom study on the behavior of Acuros XB algorithm in flattening filter free photon beams |
title_short | A phantom study on the behavior of Acuros XB algorithm in flattening filter free photon beams |
title_sort | phantom study on the behavior of acuros xb algorithm in flattening filter free photon beams |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4594383/ https://www.ncbi.nlm.nih.gov/pubmed/26500400 http://dx.doi.org/10.4103/0971-6203.165076 |
work_keys_str_mv | AT muralidharkr aphantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams AT pangamsuresh aphantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams AT srinivasp aphantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams AT atharalimirza aphantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams AT priyavsujana aphantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams AT komandurikrishna aphantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams AT muralidharkr phantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams AT pangamsuresh phantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams AT srinivasp phantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams AT atharalimirza phantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams AT priyavsujana phantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams AT komandurikrishna phantomstudyonthebehaviorofacurosxbalgorithminflatteningfilterfreephotonbeams |