Cargando…
Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler
In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4594387/ https://www.ncbi.nlm.nih.gov/pubmed/26500404 http://dx.doi.org/10.4103/0971-6203.165073 |
_version_ | 1782393444184883200 |
---|---|
author | Saravanakumar, A. Vaideki, K. Govindarajan, K. N. Jayakumar, S. Devanand, B. |
author_facet | Saravanakumar, A. Vaideki, K. Govindarajan, K. N. Jayakumar, S. Devanand, B. |
author_sort | Saravanakumar, A. |
collection | PubMed |
description | In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP). Using these values, the weighted computed tomography dose index (CTDI(w)) and in turn the volumetric CTDI (CTDI(v)) were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDI(v) measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB), India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry. |
format | Online Article Text |
id | pubmed-4594387 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-45943872015-10-23 Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler Saravanakumar, A. Vaideki, K. Govindarajan, K. N. Jayakumar, S. Devanand, B. J Med Phys Technical Note In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP). Using these values, the weighted computed tomography dose index (CTDI(w)) and in turn the volumetric CTDI (CTDI(v)) were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDI(v) measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB), India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4594387/ /pubmed/26500404 http://dx.doi.org/10.4103/0971-6203.165073 Text en Copyright: © 2015 Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Technical Note Saravanakumar, A. Vaideki, K. Govindarajan, K. N. Jayakumar, S. Devanand, B. Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler |
title | Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler |
title_full | Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler |
title_fullStr | Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler |
title_full_unstemmed | Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler |
title_short | Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler |
title_sort | cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and ct dose profiler |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4594387/ https://www.ncbi.nlm.nih.gov/pubmed/26500404 http://dx.doi.org/10.4103/0971-6203.165073 |
work_keys_str_mv | AT saravanakumara costeffectivepediatricheadandbodyphantomsforcomputedtomographydosimetryanditsevaluationusingpencilionchamberandctdoseprofiler AT vaidekik costeffectivepediatricheadandbodyphantomsforcomputedtomographydosimetryanditsevaluationusingpencilionchamberandctdoseprofiler AT govindarajankn costeffectivepediatricheadandbodyphantomsforcomputedtomographydosimetryanditsevaluationusingpencilionchamberandctdoseprofiler AT jayakumars costeffectivepediatricheadandbodyphantomsforcomputedtomographydosimetryanditsevaluationusingpencilionchamberandctdoseprofiler AT devanandb costeffectivepediatricheadandbodyphantomsforcomputedtomographydosimetryanditsevaluationusingpencilionchamberandctdoseprofiler |