Cargando…

Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler

In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length...

Descripción completa

Detalles Bibliográficos
Autores principales: Saravanakumar, A., Vaideki, K., Govindarajan, K. N., Jayakumar, S., Devanand, B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4594387/
https://www.ncbi.nlm.nih.gov/pubmed/26500404
http://dx.doi.org/10.4103/0971-6203.165073
_version_ 1782393444184883200
author Saravanakumar, A.
Vaideki, K.
Govindarajan, K. N.
Jayakumar, S.
Devanand, B.
author_facet Saravanakumar, A.
Vaideki, K.
Govindarajan, K. N.
Jayakumar, S.
Devanand, B.
author_sort Saravanakumar, A.
collection PubMed
description In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP). Using these values, the weighted computed tomography dose index (CTDI(w)) and in turn the volumetric CTDI (CTDI(v)) were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDI(v) measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB), India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry.
format Online
Article
Text
id pubmed-4594387
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-45943872015-10-23 Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler Saravanakumar, A. Vaideki, K. Govindarajan, K. N. Jayakumar, S. Devanand, B. J Med Phys Technical Note In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP). Using these values, the weighted computed tomography dose index (CTDI(w)) and in turn the volumetric CTDI (CTDI(v)) were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDI(v) measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB), India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4594387/ /pubmed/26500404 http://dx.doi.org/10.4103/0971-6203.165073 Text en Copyright: © 2015 Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Technical Note
Saravanakumar, A.
Vaideki, K.
Govindarajan, K. N.
Jayakumar, S.
Devanand, B.
Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler
title Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler
title_full Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler
title_fullStr Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler
title_full_unstemmed Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler
title_short Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler
title_sort cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and ct dose profiler
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4594387/
https://www.ncbi.nlm.nih.gov/pubmed/26500404
http://dx.doi.org/10.4103/0971-6203.165073
work_keys_str_mv AT saravanakumara costeffectivepediatricheadandbodyphantomsforcomputedtomographydosimetryanditsevaluationusingpencilionchamberandctdoseprofiler
AT vaidekik costeffectivepediatricheadandbodyphantomsforcomputedtomographydosimetryanditsevaluationusingpencilionchamberandctdoseprofiler
AT govindarajankn costeffectivepediatricheadandbodyphantomsforcomputedtomographydosimetryanditsevaluationusingpencilionchamberandctdoseprofiler
AT jayakumars costeffectivepediatricheadandbodyphantomsforcomputedtomographydosimetryanditsevaluationusingpencilionchamberandctdoseprofiler
AT devanandb costeffectivepediatricheadandbodyphantomsforcomputedtomographydosimetryanditsevaluationusingpencilionchamberandctdoseprofiler