Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors

Heart failure (HF) is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all...

Descripción completa

Detalles Bibliográficos
Autores principales: Mooney, Deirdre M., Fung, Erik, Doshi, Rahul N., Shavelle, David M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4595778/
https://www.ncbi.nlm.nih.gov/pubmed/26500556
http://dx.doi.org/10.3389/fphys.2015.00271
_version_ 1782393667196026880
author Mooney, Deirdre M.
Fung, Erik
Doshi, Rahul N.
Shavelle, David M.
author_facet Mooney, Deirdre M.
Fung, Erik
Doshi, Rahul N.
Shavelle, David M.
author_sort Mooney, Deirdre M.
collection PubMed
description Heart failure (HF) is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF) can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension.
format Online
Article
Text
id pubmed-4595778
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-45957782015-10-23 Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors Mooney, Deirdre M. Fung, Erik Doshi, Rahul N. Shavelle, David M. Front Physiol Physiology Heart failure (HF) is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF) can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension. Frontiers Media S.A. 2015-10-07 /pmc/articles/PMC4595778/ /pubmed/26500556 http://dx.doi.org/10.3389/fphys.2015.00271 Text en Copyright © 2015 Mooney, Fung, Doshi and Shavelle. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Mooney, Deirdre M.
Fung, Erik
Doshi, Rahul N.
Shavelle, David M.
Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors
title Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors
title_full Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors
title_fullStr Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors
title_full_unstemmed Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors
title_short Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors
title_sort evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4595778/
https://www.ncbi.nlm.nih.gov/pubmed/26500556
http://dx.doi.org/10.3389/fphys.2015.00271
work_keys_str_mv AT mooneydeirdrem evolutionfromelectrophysiologictohemodynamicmonitoringthestoryofleftatrialandpulmonaryarterypressuremonitors
AT fungerik evolutionfromelectrophysiologictohemodynamicmonitoringthestoryofleftatrialandpulmonaryarterypressuremonitors
AT doshirahuln evolutionfromelectrophysiologictohemodynamicmonitoringthestoryofleftatrialandpulmonaryarterypressuremonitors
AT shavelledavidm evolutionfromelectrophysiologictohemodynamicmonitoringthestoryofleftatrialandpulmonaryarterypressuremonitors