Cargando…
Chemiluminometric Immunosensor for High-Sensitivity Cardiac Troponin I Employing a Polymerized Enzyme Conjugate as a Tracer
To detect high-sensitivity cardiac troponin I (hs-cTnI; <0.01 ng/mL) at points of care, we developed a rapid immunosensor by using horseradish peroxidase polymerized in 20 molecules on average (Poly-HRP) as a tracer conjugated with streptavidin (SA-Poly-HRP). As shown in the conventional system,...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4595837/ https://www.ncbi.nlm.nih.gov/pubmed/26442606 http://dx.doi.org/10.1038/srep14848 |
_version_ | 1782393678953709568 |
---|---|
author | Lim, Guei-Sam Seo, Sung-Min Paek, Sung-Ho Kim, Seung-Wan Jeon, Jin-Woo Kim, Dong-Hyung Cho, Il-Hoon Paek, Se-Hwan |
author_facet | Lim, Guei-Sam Seo, Sung-Min Paek, Sung-Ho Kim, Seung-Wan Jeon, Jin-Woo Kim, Dong-Hyung Cho, Il-Hoon Paek, Se-Hwan |
author_sort | Lim, Guei-Sam |
collection | PubMed |
description | To detect high-sensitivity cardiac troponin I (hs-cTnI; <0.01 ng/mL) at points of care, we developed a rapid immunosensor by using horseradish peroxidase polymerized in 20 molecules on average (Poly-HRP) as a tracer conjugated with streptavidin (SA-Poly-HRP). As shown in the conventional system, enhanced sensitivity could be achieved by using a sequential binding scheme for the complex formation to contain the huge molecular tracer. We used a 2-dimensional chromatographic technology to carry out the sequential bindings in cross-flow directions. After the complex formation of antigen-antibody with analyte in a vertical direction, SA-Poly-HRP was horizontally supplied across the membrane strip for additional binding via a biotin-SA linkage. The HRP substrate was subsequently supplied along the same direction to produce a chemiluminometric signal, which was measured by a cooled charge-coupled device. Hs-cTnI analysis was completed in this format within 25 min, and the results showed a high correlation with those of the CentaurXP® reference system (R(2) > 0.99). The detection limit of the rapid immunosensor was 0.003 ± 0.001 ng/mL cTnI, corresponding to a 10-fold improvement compared to results using the plain enzyme tracer. This demonstrated the measurement of hs-cTnI in a much more cost-effective manner compared to the automated versions currently available. |
format | Online Article Text |
id | pubmed-4595837 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-45958372015-10-13 Chemiluminometric Immunosensor for High-Sensitivity Cardiac Troponin I Employing a Polymerized Enzyme Conjugate as a Tracer Lim, Guei-Sam Seo, Sung-Min Paek, Sung-Ho Kim, Seung-Wan Jeon, Jin-Woo Kim, Dong-Hyung Cho, Il-Hoon Paek, Se-Hwan Sci Rep Article To detect high-sensitivity cardiac troponin I (hs-cTnI; <0.01 ng/mL) at points of care, we developed a rapid immunosensor by using horseradish peroxidase polymerized in 20 molecules on average (Poly-HRP) as a tracer conjugated with streptavidin (SA-Poly-HRP). As shown in the conventional system, enhanced sensitivity could be achieved by using a sequential binding scheme for the complex formation to contain the huge molecular tracer. We used a 2-dimensional chromatographic technology to carry out the sequential bindings in cross-flow directions. After the complex formation of antigen-antibody with analyte in a vertical direction, SA-Poly-HRP was horizontally supplied across the membrane strip for additional binding via a biotin-SA linkage. The HRP substrate was subsequently supplied along the same direction to produce a chemiluminometric signal, which was measured by a cooled charge-coupled device. Hs-cTnI analysis was completed in this format within 25 min, and the results showed a high correlation with those of the CentaurXP® reference system (R(2) > 0.99). The detection limit of the rapid immunosensor was 0.003 ± 0.001 ng/mL cTnI, corresponding to a 10-fold improvement compared to results using the plain enzyme tracer. This demonstrated the measurement of hs-cTnI in a much more cost-effective manner compared to the automated versions currently available. Nature Publishing Group 2015-10-07 /pmc/articles/PMC4595837/ /pubmed/26442606 http://dx.doi.org/10.1038/srep14848 Text en Copyright © 2015, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Lim, Guei-Sam Seo, Sung-Min Paek, Sung-Ho Kim, Seung-Wan Jeon, Jin-Woo Kim, Dong-Hyung Cho, Il-Hoon Paek, Se-Hwan Chemiluminometric Immunosensor for High-Sensitivity Cardiac Troponin I Employing a Polymerized Enzyme Conjugate as a Tracer |
title | Chemiluminometric Immunosensor for High-Sensitivity Cardiac Troponin I Employing a Polymerized Enzyme Conjugate as a Tracer |
title_full | Chemiluminometric Immunosensor for High-Sensitivity Cardiac Troponin I Employing a Polymerized Enzyme Conjugate as a Tracer |
title_fullStr | Chemiluminometric Immunosensor for High-Sensitivity Cardiac Troponin I Employing a Polymerized Enzyme Conjugate as a Tracer |
title_full_unstemmed | Chemiluminometric Immunosensor for High-Sensitivity Cardiac Troponin I Employing a Polymerized Enzyme Conjugate as a Tracer |
title_short | Chemiluminometric Immunosensor for High-Sensitivity Cardiac Troponin I Employing a Polymerized Enzyme Conjugate as a Tracer |
title_sort | chemiluminometric immunosensor for high-sensitivity cardiac troponin i employing a polymerized enzyme conjugate as a tracer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4595837/ https://www.ncbi.nlm.nih.gov/pubmed/26442606 http://dx.doi.org/10.1038/srep14848 |
work_keys_str_mv | AT limgueisam chemiluminometricimmunosensorforhighsensitivitycardiactroponiniemployingapolymerizedenzymeconjugateasatracer AT seosungmin chemiluminometricimmunosensorforhighsensitivitycardiactroponiniemployingapolymerizedenzymeconjugateasatracer AT paeksungho chemiluminometricimmunosensorforhighsensitivitycardiactroponiniemployingapolymerizedenzymeconjugateasatracer AT kimseungwan chemiluminometricimmunosensorforhighsensitivitycardiactroponiniemployingapolymerizedenzymeconjugateasatracer AT jeonjinwoo chemiluminometricimmunosensorforhighsensitivitycardiactroponiniemployingapolymerizedenzymeconjugateasatracer AT kimdonghyung chemiluminometricimmunosensorforhighsensitivitycardiactroponiniemployingapolymerizedenzymeconjugateasatracer AT choilhoon chemiluminometricimmunosensorforhighsensitivitycardiactroponiniemployingapolymerizedenzymeconjugateasatracer AT paeksehwan chemiluminometricimmunosensorforhighsensitivitycardiactroponiniemployingapolymerizedenzymeconjugateasatracer |