Cargando…

EEG Source Imaging in Partial Epilepsy in Comparison with Presurgical Evaluation and Magnetoencephalography

BACKGROUND AND PURPOSE: The aim of this study was to determine the usefulness of three-dimensional (3D) scalp EEG source imaging (ESI) in partial epilepsy in comparison with the results of presurgical evaluation, magnetoencephalography (MEG), and electrocorticography (ECoG). METHODS: The epilepsy sy...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Chae Jung, Seo, Ji Hye, Kim, Daeyoung, Abibullaev, Berdakh, Kwon, Hyukchan, Lee, Yong-Ho, Kim, Min-Young, An, Kyung-min, Kim, Kiwoong, Kim, Jeong Sik, Joo, Eun Yeon, Hong, Seung Bong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Neurological Association 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4596098/
https://www.ncbi.nlm.nih.gov/pubmed/25749824
http://dx.doi.org/10.3988/jcn.2015.11.4.319
Descripción
Sumario:BACKGROUND AND PURPOSE: The aim of this study was to determine the usefulness of three-dimensional (3D) scalp EEG source imaging (ESI) in partial epilepsy in comparison with the results of presurgical evaluation, magnetoencephalography (MEG), and electrocorticography (ECoG). METHODS: The epilepsy syndrome of 27 partial epilepsy patients was determined by presurgical evaluations. EEG recordings were made using 70 scalp electrodes, and the 3D coordinates of the electrodes were digitized. ESI images of individual and averaged spikes were analyzed by Curry software with a boundary element method. MEG and ECoG were performed in 23 and 9 patients, respectively. RESULTS: ESI and MEG source imaging (MSI) results were well concordant with the results of presurgical evaluations (in 96.3% and 100% cases for ESI and MSI, respectively) at the lobar level. However, there were no spikes in the MEG recordings of three patients. The ESI results were well concordant with MSI results in 90.0% of cases. Compared to ECoG, the ESI results tended to be localized deeper than the cortex, whereas the MSI results were generally localized on the cortical surface. ESI was well concordant with ECoG in 8 of 9 (88.9%) cases, and MSI was also well concordant with ECoG in 4 of 5 (80.0%) cases. The EEG single dipoles in one patient with mesial temporal lobe epilepsy were tightly clustered with the averaged dipole when a 3 Hz high-pass filter was used. CONCLUSIONS: The ESI results were well concordant with the results of the presurgical evaluation, MSI, and ECoG. The ESI analysis was found to be useful for localizing the seizure focus and is recommended for the presurgical evaluation of intractable epilepsy patients.