Cargando…
A percutaneous needle biopsy technique for sampling the supraclavicular brown adipose tissue depot of humans
Brown adipose tissue (BAT) has been proposed as a potential target tissue against obesity and its related metabolic complications. Although the molecular and functional characteristics of BAT have been intensively studied in rodents, only a small number of studies have used human BAT specimens due t...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4596746/ https://www.ncbi.nlm.nih.gov/pubmed/25920777 http://dx.doi.org/10.1038/ijo.2015.76 |
_version_ | 1782393805871251456 |
---|---|
author | Annamalai, Palam Chondronikola, Maria Chao, Tony Porter, Craig Saraf, Manish K. Cesani, Fernardo Sidossis, Labros S. |
author_facet | Annamalai, Palam Chondronikola, Maria Chao, Tony Porter, Craig Saraf, Manish K. Cesani, Fernardo Sidossis, Labros S. |
author_sort | Annamalai, Palam |
collection | PubMed |
description | Brown adipose tissue (BAT) has been proposed as a potential target tissue against obesity and its related metabolic complications. Although the molecular and functional characteristics of BAT have been intensively studied in rodents, only a small number of studies have used human BAT specimens due to the difficulty of sampling human BAT deposits. We established a novel positron emission tomography and computed tomography-guided Bergström needle biopsy technique to acquire human BAT specimens from the supraclavicular area in human subjects. Forty-three biopsies were performed on 23 participants. The procedure was tolerated well by the majority of participants. No major complications were noted. Numbness (9.6%) and hematoma (2.3%) were the two minor complications noted, which fully resolved. Thus, the proposed biopsy technique can be considered safe with only minimal risk of adverse events. Adoption of the proposed method is expected to increase the sampling of the supraclavicular BAT depot for research purposes so as to augment the scientific knowledge of the biology of human BAT. |
format | Online Article Text |
id | pubmed-4596746 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
record_format | MEDLINE/PubMed |
spelling | pubmed-45967462016-04-01 A percutaneous needle biopsy technique for sampling the supraclavicular brown adipose tissue depot of humans Annamalai, Palam Chondronikola, Maria Chao, Tony Porter, Craig Saraf, Manish K. Cesani, Fernardo Sidossis, Labros S. Int J Obes (Lond) Article Brown adipose tissue (BAT) has been proposed as a potential target tissue against obesity and its related metabolic complications. Although the molecular and functional characteristics of BAT have been intensively studied in rodents, only a small number of studies have used human BAT specimens due to the difficulty of sampling human BAT deposits. We established a novel positron emission tomography and computed tomography-guided Bergström needle biopsy technique to acquire human BAT specimens from the supraclavicular area in human subjects. Forty-three biopsies were performed on 23 participants. The procedure was tolerated well by the majority of participants. No major complications were noted. Numbness (9.6%) and hematoma (2.3%) were the two minor complications noted, which fully resolved. Thus, the proposed biopsy technique can be considered safe with only minimal risk of adverse events. Adoption of the proposed method is expected to increase the sampling of the supraclavicular BAT depot for research purposes so as to augment the scientific knowledge of the biology of human BAT. 2015-04-29 2015-10 /pmc/articles/PMC4596746/ /pubmed/25920777 http://dx.doi.org/10.1038/ijo.2015.76 Text en http://www.nature.com/authors/editorial_policies/license.html#terms Users may view, print, copy, and download text and data-mine the content in such documents, for the purposes of academic research, subject always to the full Conditions of use:http://www.nature.com/authors/editorial_policies/license.html#terms |
spellingShingle | Article Annamalai, Palam Chondronikola, Maria Chao, Tony Porter, Craig Saraf, Manish K. Cesani, Fernardo Sidossis, Labros S. A percutaneous needle biopsy technique for sampling the supraclavicular brown adipose tissue depot of humans |
title | A percutaneous needle biopsy technique for sampling the supraclavicular brown adipose tissue depot of humans |
title_full | A percutaneous needle biopsy technique for sampling the supraclavicular brown adipose tissue depot of humans |
title_fullStr | A percutaneous needle biopsy technique for sampling the supraclavicular brown adipose tissue depot of humans |
title_full_unstemmed | A percutaneous needle biopsy technique for sampling the supraclavicular brown adipose tissue depot of humans |
title_short | A percutaneous needle biopsy technique for sampling the supraclavicular brown adipose tissue depot of humans |
title_sort | percutaneous needle biopsy technique for sampling the supraclavicular brown adipose tissue depot of humans |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4596746/ https://www.ncbi.nlm.nih.gov/pubmed/25920777 http://dx.doi.org/10.1038/ijo.2015.76 |
work_keys_str_mv | AT annamalaipalam apercutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT chondronikolamaria apercutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT chaotony apercutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT portercraig apercutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT sarafmanishk apercutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT cesanifernardo apercutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT sidossislabross apercutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT annamalaipalam percutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT chondronikolamaria percutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT chaotony percutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT portercraig percutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT sarafmanishk percutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT cesanifernardo percutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans AT sidossislabross percutaneousneedlebiopsytechniqueforsamplingthesupraclavicularbrownadiposetissuedepotofhumans |