Cargando…

Are Early Results of Robotic Assisted Medial Unicompartmental Knee Arthroplasty Successful?

OBJECTIVES: Robotic surgery studies have been increasing in literature in the past years due to its operative advantages on reducing error and improving functional success in partial knee arthroplasty. METHODS: Data were prospectively collected in 21 patients (31 knees) who underwent MAKOplasty, rob...

Descripción completa

Detalles Bibliográficos
Autores principales: Haklar, Uğur, Ulusoy, Ertuğrul, Şimşek, Tayfun, Terzi, Nuray
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4597635/
http://dx.doi.org/10.1177/2325967114S00138
Descripción
Sumario:OBJECTIVES: Robotic surgery studies have been increasing in literature in the past years due to its operative advantages on reducing error and improving functional success in partial knee arthroplasty. METHODS: Data were prospectively collected in 21 patients (31 knees) who underwent MAKOplasty, robotic assisted unicondylar medial knee arthroplasty, between June 2013 – January 2014 in our clinic with an average follow-up time of 5.5 months. Clinical outcomes were evaluated with American Knee Society Scoring System. Additionally, intra-operative digitally planned implant positions on the robot’s software were compared with post-operative radiographic component alignment. In the radiographic evaluation; anatomic axis of the tibia was observed in the coronal plane. Tibial posterior slope and flexion angle of the femoral component were observed in the sagittal plane. RESULTS: Pre-operatively 1 patient was scored fair (60 points) and 20 patients were scored poor (mean, 46.6 points) on American Knee Society Scoring System. Post-operatively all 21 patients had excellent knee scores (mean, 99.67 points). Function-wise 7 patients were scored fair (mean, 60 points) and 14 patients were scored poor (mean, 30.7 points) again on American Knee Society Functional Scoring System. Post-operatively all 21 patients exhibited excellent function scores (mean, 99.04 points). In the radiological evaluation, intra-operative robotic analyses were compared with post-operative radiographic alignment. No significant difference was observed statistically (paired t-test, p < 0.05). This comparison is valuable as Lonner, Hernigou, Collier report that mal-alignment by as little as 2° may predispose to implant failures. CONCLUSION: Robotic assistance greatly improves clinical and functional outcomes and may help prevent implant failures due to surgical error and mal-alignment in partial knee arthroplasty.