Cargando…
Relationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty
This study evaluated the influence of modern tibial baseplate designs when using the anterior tibial cortex as a primary rotational landmark for the tibial baseplate in TKA. Eighty patients undergoing TKA were randomized in two groups. Group 1 included 25 females and 15 males receiving a posterior-s...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4600913/ https://www.ncbi.nlm.nih.gov/pubmed/26491564 http://dx.doi.org/10.1155/2015/189294 |
_version_ | 1782394480457940992 |
---|---|
author | Indelli, Pier Francesco Graceffa, Angelo Baldini, Andrea Payne, Brielle Pipino, Gennaro Marcucci, Massimiliano |
author_facet | Indelli, Pier Francesco Graceffa, Angelo Baldini, Andrea Payne, Brielle Pipino, Gennaro Marcucci, Massimiliano |
author_sort | Indelli, Pier Francesco |
collection | PubMed |
description | This study evaluated the influence of modern tibial baseplate designs when using the anterior tibial cortex as a primary rotational landmark for the tibial baseplate in TKA. Eighty patients undergoing TKA were randomized in two groups. Group 1 included 25 females and 15 males receiving a posterior-stabilized (PS) symmetric tibial baseplate while Group 2 included 24 females and 16 males receiving a PS anatomical tibial component. Identical surgical technique, including the use of the surgical transepicondylar femoral axis (sTEA) and the anterior tibial cortex (“Curve-on-Curve”) as rotational alignment landmarks, was used. All patients underwent CT evaluation performed with the knee in full extension. Three observers independently measured the rotational alignment of the tibial component in relation to the sTEA. The rotational alignment of the symmetric baseplate showed an average external rotation of 1.3° (minimum 5°, maximum −1°): 91% of the knees showed 0 ± 3° with respect to the surgical sTEA, being internally rotated in 20%. The rotational alignment of the anatomical baseplate showed an average external rotation of 4.1° (minimum 0.4°, maximum 8.9°): only 47.5% of the knees showed 0 ± 3°, being externally rotated in 100%. The difference between the two groups was statistically significant. This study confirms the reliability of the “Curve-on-Curve” technique as an adequate rotational alignment anatomical landmark in TKA: the use of an asymmetric tibial baseplate might lead to external rotation of the tibial component when this technique is intraoperatively chosen. |
format | Online Article Text |
id | pubmed-4600913 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-46009132015-10-21 Relationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty Indelli, Pier Francesco Graceffa, Angelo Baldini, Andrea Payne, Brielle Pipino, Gennaro Marcucci, Massimiliano Arthritis Clinical Study This study evaluated the influence of modern tibial baseplate designs when using the anterior tibial cortex as a primary rotational landmark for the tibial baseplate in TKA. Eighty patients undergoing TKA were randomized in two groups. Group 1 included 25 females and 15 males receiving a posterior-stabilized (PS) symmetric tibial baseplate while Group 2 included 24 females and 16 males receiving a PS anatomical tibial component. Identical surgical technique, including the use of the surgical transepicondylar femoral axis (sTEA) and the anterior tibial cortex (“Curve-on-Curve”) as rotational alignment landmarks, was used. All patients underwent CT evaluation performed with the knee in full extension. Three observers independently measured the rotational alignment of the tibial component in relation to the sTEA. The rotational alignment of the symmetric baseplate showed an average external rotation of 1.3° (minimum 5°, maximum −1°): 91% of the knees showed 0 ± 3° with respect to the surgical sTEA, being internally rotated in 20%. The rotational alignment of the anatomical baseplate showed an average external rotation of 4.1° (minimum 0.4°, maximum 8.9°): only 47.5% of the knees showed 0 ± 3°, being externally rotated in 100%. The difference between the two groups was statistically significant. This study confirms the reliability of the “Curve-on-Curve” technique as an adequate rotational alignment anatomical landmark in TKA: the use of an asymmetric tibial baseplate might lead to external rotation of the tibial component when this technique is intraoperatively chosen. Hindawi Publishing Corporation 2015 2015-09-28 /pmc/articles/PMC4600913/ /pubmed/26491564 http://dx.doi.org/10.1155/2015/189294 Text en Copyright © 2015 Pier Francesco Indelli et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Indelli, Pier Francesco Graceffa, Angelo Baldini, Andrea Payne, Brielle Pipino, Gennaro Marcucci, Massimiliano Relationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty |
title | Relationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty |
title_full | Relationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty |
title_fullStr | Relationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty |
title_full_unstemmed | Relationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty |
title_short | Relationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty |
title_sort | relationship between tibial baseplate design and rotational alignment landmarks in primary total knee arthroplasty |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4600913/ https://www.ncbi.nlm.nih.gov/pubmed/26491564 http://dx.doi.org/10.1155/2015/189294 |
work_keys_str_mv | AT indellipierfrancesco relationshipbetweentibialbaseplatedesignandrotationalalignmentlandmarksinprimarytotalkneearthroplasty AT graceffaangelo relationshipbetweentibialbaseplatedesignandrotationalalignmentlandmarksinprimarytotalkneearthroplasty AT baldiniandrea relationshipbetweentibialbaseplatedesignandrotationalalignmentlandmarksinprimarytotalkneearthroplasty AT paynebrielle relationshipbetweentibialbaseplatedesignandrotationalalignmentlandmarksinprimarytotalkneearthroplasty AT pipinogennaro relationshipbetweentibialbaseplatedesignandrotationalalignmentlandmarksinprimarytotalkneearthroplasty AT marcuccimassimiliano relationshipbetweentibialbaseplatedesignandrotationalalignmentlandmarksinprimarytotalkneearthroplasty |