Cargando…

Fecal Fistula Communicating with a Femur Shaft Fracture Secondary to a Malpositioned Suprapubic Catheter: A Case Report

Patient: Male, 18 Final Diagnosis: Fecal fistula communicating with fracture shaft femur secondary to malpositioned SPC Symptoms: — Medication: — Clinical Procedure: Advertisement and rail fixator application Specialty: Orthopedics and Trauamtology OBJECTIVE: Diagnostic/therapeutic accidents BACKGRO...

Descripción completa

Detalles Bibliográficos
Autores principales: Guled, Uday, Goni, Vijay G., Honnurappa, Arjun R.H., John, Rakesh, Vardhana, Harsha, Sharma, Gaurav, Pattabhiraman, Kirubakaran S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4601354/
https://www.ncbi.nlm.nih.gov/pubmed/26439133
http://dx.doi.org/10.12659/AJCR.894516
_version_ 1782394539623841792
author Guled, Uday
Goni, Vijay G.
Honnurappa, Arjun R.H.
John, Rakesh
Vardhana, Harsha
Sharma, Gaurav
Pattabhiraman, Kirubakaran S.
author_facet Guled, Uday
Goni, Vijay G.
Honnurappa, Arjun R.H.
John, Rakesh
Vardhana, Harsha
Sharma, Gaurav
Pattabhiraman, Kirubakaran S.
author_sort Guled, Uday
collection PubMed
description Patient: Male, 18 Final Diagnosis: Fecal fistula communicating with fracture shaft femur secondary to malpositioned SPC Symptoms: — Medication: — Clinical Procedure: Advertisement and rail fixator application Specialty: Orthopedics and Trauamtology OBJECTIVE: Diagnostic/therapeutic accidents BACKGROUND: Suprapubic catheter (SPC) insertion is a common urological procedure. Though considered a simple and safe procedure, complications are bound to occur if proper precautions are not taken during the procedure. The reported complications include gross hematuria, post-obstruction diuresis, insertion site skin-related complications, and intra-abdominal visceral injuries. Iatrogenic bowel injuries have been reported to occur as a complication in around 2.5% of cases. CASE REPORT: We report a very rare case of a bowel injury due to improper insertion of a SPC leading to fecal matter tracking along the muscle planes to reach the fracture site of the femur shaft and formation of an external fecal fistula along the lateral aspect of thigh, which according to us is the first reported case in the literature. CONCLUSIONS: This case report shows the devastating complication of a technically simple procedure done in an improper manner and successful management of a rare case of femur fracture with communicating fecal fistula. The purpose of this case report is to highlight the importance of taking proper precautions before the procedure.
format Online
Article
Text
id pubmed-4601354
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-46013542015-10-26 Fecal Fistula Communicating with a Femur Shaft Fracture Secondary to a Malpositioned Suprapubic Catheter: A Case Report Guled, Uday Goni, Vijay G. Honnurappa, Arjun R.H. John, Rakesh Vardhana, Harsha Sharma, Gaurav Pattabhiraman, Kirubakaran S. Am J Case Rep Articles Patient: Male, 18 Final Diagnosis: Fecal fistula communicating with fracture shaft femur secondary to malpositioned SPC Symptoms: — Medication: — Clinical Procedure: Advertisement and rail fixator application Specialty: Orthopedics and Trauamtology OBJECTIVE: Diagnostic/therapeutic accidents BACKGROUND: Suprapubic catheter (SPC) insertion is a common urological procedure. Though considered a simple and safe procedure, complications are bound to occur if proper precautions are not taken during the procedure. The reported complications include gross hematuria, post-obstruction diuresis, insertion site skin-related complications, and intra-abdominal visceral injuries. Iatrogenic bowel injuries have been reported to occur as a complication in around 2.5% of cases. CASE REPORT: We report a very rare case of a bowel injury due to improper insertion of a SPC leading to fecal matter tracking along the muscle planes to reach the fracture site of the femur shaft and formation of an external fecal fistula along the lateral aspect of thigh, which according to us is the first reported case in the literature. CONCLUSIONS: This case report shows the devastating complication of a technically simple procedure done in an improper manner and successful management of a rare case of femur fracture with communicating fecal fistula. The purpose of this case report is to highlight the importance of taking proper precautions before the procedure. International Scientific Literature, Inc. 2015-10-06 /pmc/articles/PMC4601354/ /pubmed/26439133 http://dx.doi.org/10.12659/AJCR.894516 Text en © Am J Case Rep, 2015 This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License
spellingShingle Articles
Guled, Uday
Goni, Vijay G.
Honnurappa, Arjun R.H.
John, Rakesh
Vardhana, Harsha
Sharma, Gaurav
Pattabhiraman, Kirubakaran S.
Fecal Fistula Communicating with a Femur Shaft Fracture Secondary to a Malpositioned Suprapubic Catheter: A Case Report
title Fecal Fistula Communicating with a Femur Shaft Fracture Secondary to a Malpositioned Suprapubic Catheter: A Case Report
title_full Fecal Fistula Communicating with a Femur Shaft Fracture Secondary to a Malpositioned Suprapubic Catheter: A Case Report
title_fullStr Fecal Fistula Communicating with a Femur Shaft Fracture Secondary to a Malpositioned Suprapubic Catheter: A Case Report
title_full_unstemmed Fecal Fistula Communicating with a Femur Shaft Fracture Secondary to a Malpositioned Suprapubic Catheter: A Case Report
title_short Fecal Fistula Communicating with a Femur Shaft Fracture Secondary to a Malpositioned Suprapubic Catheter: A Case Report
title_sort fecal fistula communicating with a femur shaft fracture secondary to a malpositioned suprapubic catheter: a case report
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4601354/
https://www.ncbi.nlm.nih.gov/pubmed/26439133
http://dx.doi.org/10.12659/AJCR.894516
work_keys_str_mv AT guleduday fecalfistulacommunicatingwithafemurshaftfracturesecondarytoamalpositionedsuprapubiccatheteracasereport
AT gonivijayg fecalfistulacommunicatingwithafemurshaftfracturesecondarytoamalpositionedsuprapubiccatheteracasereport
AT honnurappaarjunrh fecalfistulacommunicatingwithafemurshaftfracturesecondarytoamalpositionedsuprapubiccatheteracasereport
AT johnrakesh fecalfistulacommunicatingwithafemurshaftfracturesecondarytoamalpositionedsuprapubiccatheteracasereport
AT vardhanaharsha fecalfistulacommunicatingwithafemurshaftfracturesecondarytoamalpositionedsuprapubiccatheteracasereport
AT sharmagaurav fecalfistulacommunicatingwithafemurshaftfracturesecondarytoamalpositionedsuprapubiccatheteracasereport
AT pattabhiramankirubakarans fecalfistulacommunicatingwithafemurshaftfracturesecondarytoamalpositionedsuprapubiccatheteracasereport