Cargando…

Renal Cyst Pseudoenhancement: Intraindividual Comparison Between Virtual Monochromatic Spectral Images and Conventional Polychromatic 120-kVp Images Obtained During the Same CT Examination and Comparisons Among Images Reconstructed Using Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and Model-Based Iterative Reconstruction

The purpose of this study was to compare renal cyst pseudoenhancement between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp images obtained during the same abdominal computed tomography (CT) examination and among images reconstructed using filtered back projection (FBP)...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamada, Yoshitake, Yamada, Minoru, Sugisawa, Koichi, Akita, Hirotaka, Shiomi, Eisuke, Abe, Takayuki, Okuda, Shigeo, Jinzaki, Masahiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4602515/
https://www.ncbi.nlm.nih.gov/pubmed/25881852
http://dx.doi.org/10.1097/MD.0000000000000754
_version_ 1782394735354183680
author Yamada, Yoshitake
Yamada, Minoru
Sugisawa, Koichi
Akita, Hirotaka
Shiomi, Eisuke
Abe, Takayuki
Okuda, Shigeo
Jinzaki, Masahiro
author_facet Yamada, Yoshitake
Yamada, Minoru
Sugisawa, Koichi
Akita, Hirotaka
Shiomi, Eisuke
Abe, Takayuki
Okuda, Shigeo
Jinzaki, Masahiro
author_sort Yamada, Yoshitake
collection PubMed
description The purpose of this study was to compare renal cyst pseudoenhancement between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp images obtained during the same abdominal computed tomography (CT) examination and among images reconstructed using filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR). Our institutional review board approved this prospective study; each participant provided written informed consent. Thirty-one patients (19 men, 12 women; age range, 59–85 years; mean age, 73.2 ± 5.5 years) with renal cysts underwent unenhanced 120-kVp CT followed by sequential fast kVp-switching dual-energy (80/140 kVp) and 120-kVp abdominal enhanced CT in the nephrographic phase over a 10-cm scan length with a random acquisition order and 4.5-second intervals. Fifty-one renal cysts (maximal diameter, 18.0 ± 14.7 mm [range, 4–61 mm]) were identified. The CT attenuation values of the cysts as well as of the kidneys were measured on the unenhanced images, enhanced VMS images (at 70 keV) reconstructed using FBP and ASIR from dual-energy data, and enhanced 120-kVp images reconstructed using FBP, ASIR, and MBIR. The results were analyzed using the mixed-effects model and paired t test with Bonferroni correction. The attenuation increases (pseudoenhancement) of the renal cysts on the VMS images reconstructed using FBP/ASIR (least square mean, 5.0/6.0 Hounsfield units [HU]; 95% confidence interval, 2.6–7.4/3.6–8.4 HU) were significantly lower than those on the conventional 120-kVp images reconstructed using FBP/ASIR/MBIR (least square mean, 12.1/12.8/11.8 HU; 95% confidence interval, 9.8–14.5/10.4–15.1/9.4–14.2 HU) (all P < .001); on the other hand, the CT attenuation values of the kidneys on the VMS images were comparable to those on the 120-kVp images. Regardless of the reconstruction algorithm, 70-keV VMS images showed a lower degree of pseudoenhancement of renal cysts than 120-kVp images, while maintaining kidney contrast enhancement comparable to that on 120-kVp images.
format Online
Article
Text
id pubmed-4602515
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-46025152015-10-27 Renal Cyst Pseudoenhancement: Intraindividual Comparison Between Virtual Monochromatic Spectral Images and Conventional Polychromatic 120-kVp Images Obtained During the Same CT Examination and Comparisons Among Images Reconstructed Using Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and Model-Based Iterative Reconstruction Yamada, Yoshitake Yamada, Minoru Sugisawa, Koichi Akita, Hirotaka Shiomi, Eisuke Abe, Takayuki Okuda, Shigeo Jinzaki, Masahiro Medicine (Baltimore) 6800 The purpose of this study was to compare renal cyst pseudoenhancement between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp images obtained during the same abdominal computed tomography (CT) examination and among images reconstructed using filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR). Our institutional review board approved this prospective study; each participant provided written informed consent. Thirty-one patients (19 men, 12 women; age range, 59–85 years; mean age, 73.2 ± 5.5 years) with renal cysts underwent unenhanced 120-kVp CT followed by sequential fast kVp-switching dual-energy (80/140 kVp) and 120-kVp abdominal enhanced CT in the nephrographic phase over a 10-cm scan length with a random acquisition order and 4.5-second intervals. Fifty-one renal cysts (maximal diameter, 18.0 ± 14.7 mm [range, 4–61 mm]) were identified. The CT attenuation values of the cysts as well as of the kidneys were measured on the unenhanced images, enhanced VMS images (at 70 keV) reconstructed using FBP and ASIR from dual-energy data, and enhanced 120-kVp images reconstructed using FBP, ASIR, and MBIR. The results were analyzed using the mixed-effects model and paired t test with Bonferroni correction. The attenuation increases (pseudoenhancement) of the renal cysts on the VMS images reconstructed using FBP/ASIR (least square mean, 5.0/6.0 Hounsfield units [HU]; 95% confidence interval, 2.6–7.4/3.6–8.4 HU) were significantly lower than those on the conventional 120-kVp images reconstructed using FBP/ASIR/MBIR (least square mean, 12.1/12.8/11.8 HU; 95% confidence interval, 9.8–14.5/10.4–15.1/9.4–14.2 HU) (all P < .001); on the other hand, the CT attenuation values of the kidneys on the VMS images were comparable to those on the 120-kVp images. Regardless of the reconstruction algorithm, 70-keV VMS images showed a lower degree of pseudoenhancement of renal cysts than 120-kVp images, while maintaining kidney contrast enhancement comparable to that on 120-kVp images. Wolters Kluwer Health 2015-04-17 /pmc/articles/PMC4602515/ /pubmed/25881852 http://dx.doi.org/10.1097/MD.0000000000000754 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0, where it is permissible to download, share and reproduce the work in any medium, provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle 6800
Yamada, Yoshitake
Yamada, Minoru
Sugisawa, Koichi
Akita, Hirotaka
Shiomi, Eisuke
Abe, Takayuki
Okuda, Shigeo
Jinzaki, Masahiro
Renal Cyst Pseudoenhancement: Intraindividual Comparison Between Virtual Monochromatic Spectral Images and Conventional Polychromatic 120-kVp Images Obtained During the Same CT Examination and Comparisons Among Images Reconstructed Using Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and Model-Based Iterative Reconstruction
title Renal Cyst Pseudoenhancement: Intraindividual Comparison Between Virtual Monochromatic Spectral Images and Conventional Polychromatic 120-kVp Images Obtained During the Same CT Examination and Comparisons Among Images Reconstructed Using Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and Model-Based Iterative Reconstruction
title_full Renal Cyst Pseudoenhancement: Intraindividual Comparison Between Virtual Monochromatic Spectral Images and Conventional Polychromatic 120-kVp Images Obtained During the Same CT Examination and Comparisons Among Images Reconstructed Using Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and Model-Based Iterative Reconstruction
title_fullStr Renal Cyst Pseudoenhancement: Intraindividual Comparison Between Virtual Monochromatic Spectral Images and Conventional Polychromatic 120-kVp Images Obtained During the Same CT Examination and Comparisons Among Images Reconstructed Using Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and Model-Based Iterative Reconstruction
title_full_unstemmed Renal Cyst Pseudoenhancement: Intraindividual Comparison Between Virtual Monochromatic Spectral Images and Conventional Polychromatic 120-kVp Images Obtained During the Same CT Examination and Comparisons Among Images Reconstructed Using Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and Model-Based Iterative Reconstruction
title_short Renal Cyst Pseudoenhancement: Intraindividual Comparison Between Virtual Monochromatic Spectral Images and Conventional Polychromatic 120-kVp Images Obtained During the Same CT Examination and Comparisons Among Images Reconstructed Using Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and Model-Based Iterative Reconstruction
title_sort renal cyst pseudoenhancement: intraindividual comparison between virtual monochromatic spectral images and conventional polychromatic 120-kvp images obtained during the same ct examination and comparisons among images reconstructed using filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction
topic 6800
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4602515/
https://www.ncbi.nlm.nih.gov/pubmed/25881852
http://dx.doi.org/10.1097/MD.0000000000000754
work_keys_str_mv AT yamadayoshitake renalcystpseudoenhancementintraindividualcomparisonbetweenvirtualmonochromaticspectralimagesandconventionalpolychromatic120kvpimagesobtainedduringthesamectexaminationandcomparisonsamongimagesreconstructedusingfilteredbackprojectionadaptivestatisticalitera
AT yamadaminoru renalcystpseudoenhancementintraindividualcomparisonbetweenvirtualmonochromaticspectralimagesandconventionalpolychromatic120kvpimagesobtainedduringthesamectexaminationandcomparisonsamongimagesreconstructedusingfilteredbackprojectionadaptivestatisticalitera
AT sugisawakoichi renalcystpseudoenhancementintraindividualcomparisonbetweenvirtualmonochromaticspectralimagesandconventionalpolychromatic120kvpimagesobtainedduringthesamectexaminationandcomparisonsamongimagesreconstructedusingfilteredbackprojectionadaptivestatisticalitera
AT akitahirotaka renalcystpseudoenhancementintraindividualcomparisonbetweenvirtualmonochromaticspectralimagesandconventionalpolychromatic120kvpimagesobtainedduringthesamectexaminationandcomparisonsamongimagesreconstructedusingfilteredbackprojectionadaptivestatisticalitera
AT shiomieisuke renalcystpseudoenhancementintraindividualcomparisonbetweenvirtualmonochromaticspectralimagesandconventionalpolychromatic120kvpimagesobtainedduringthesamectexaminationandcomparisonsamongimagesreconstructedusingfilteredbackprojectionadaptivestatisticalitera
AT abetakayuki renalcystpseudoenhancementintraindividualcomparisonbetweenvirtualmonochromaticspectralimagesandconventionalpolychromatic120kvpimagesobtainedduringthesamectexaminationandcomparisonsamongimagesreconstructedusingfilteredbackprojectionadaptivestatisticalitera
AT okudashigeo renalcystpseudoenhancementintraindividualcomparisonbetweenvirtualmonochromaticspectralimagesandconventionalpolychromatic120kvpimagesobtainedduringthesamectexaminationandcomparisonsamongimagesreconstructedusingfilteredbackprojectionadaptivestatisticalitera
AT jinzakimasahiro renalcystpseudoenhancementintraindividualcomparisonbetweenvirtualmonochromaticspectralimagesandconventionalpolychromatic120kvpimagesobtainedduringthesamectexaminationandcomparisonsamongimagesreconstructedusingfilteredbackprojectionadaptivestatisticalitera