Cargando…

Risk Factors Influencing Complications of Cardiac Implantable Electronic Device Implantation: Infection, Pneumothorax and Heart Perforation: A Nationwide Population-Based Cohort Study

As the number of cardiac implantable electronic devices (CIEDs) is increasing annually, CIED-related complications are becoming increasingly important. The aim of the study was to assess the risks associated with CIEDs by a nationwide database. Patients were selected from the Taiwan National Health...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Yu-Sheng, Hung, Sheng-Ping, Chen, Pei-Rung, Yang, Chia-Hung, Wo, Hung-Ta, Chang, Po-Cheng, Wang, Chun-Chieh, Chou, Chung-Chuan, Wen, Ming-Shien, Chung, Chang-Ming, Chen, Tien-Hsing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4602772/
https://www.ncbi.nlm.nih.gov/pubmed/25501080
http://dx.doi.org/10.1097/MD.0000000000000213
_version_ 1782394788536909824
author Lin, Yu-Sheng
Hung, Sheng-Ping
Chen, Pei-Rung
Yang, Chia-Hung
Wo, Hung-Ta
Chang, Po-Cheng
Wang, Chun-Chieh
Chou, Chung-Chuan
Wen, Ming-Shien
Chung, Chang-Ming
Chen, Tien-Hsing
author_facet Lin, Yu-Sheng
Hung, Sheng-Ping
Chen, Pei-Rung
Yang, Chia-Hung
Wo, Hung-Ta
Chang, Po-Cheng
Wang, Chun-Chieh
Chou, Chung-Chuan
Wen, Ming-Shien
Chung, Chang-Ming
Chen, Tien-Hsing
author_sort Lin, Yu-Sheng
collection PubMed
description As the number of cardiac implantable electronic devices (CIEDs) is increasing annually, CIED-related complications are becoming increasingly important. The aim of the study was to assess the risks associated with CIEDs by a nationwide database. Patients were selected from the Taiwan National Health Insurance Database. Admissions for CIED implantation, replacement, and revision were evaluated and the evaluation period was 14 years. Endpoints included CIED-related infection, pneumothorax, and heart perforation. The study included 40,608 patients with a mean age of 71.8 ± 13.3 years. Regarding infection, the incidence rate was 2.45 per 1000 CIED-years. Male gender, younger age, device replacement, and previous infection were risks for infection while old age and high-volume centers (>200 per year) were protectors. The incidence of pneumothorax was 0.6%, with an increased risk in individuals who had chronic obstructive lung disease (COPD) and cardiac resynchronized therapy (CRT). The incidence of heart perforation was 0.09%, with an increased risk in individuals who had pre-operation temporal pacing and steroid use. High-volume center was found to decrease infection rate while male gender, young people, and individuals who underwent replacements were associated with an increased risk of infection. Additionally, pre-operation temporal pacing and steroid use should be avoided if possible. Furthermore, COPD patients or those who accept CRTs should be monitored closely.
format Online
Article
Text
id pubmed-4602772
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-46027722015-10-27 Risk Factors Influencing Complications of Cardiac Implantable Electronic Device Implantation: Infection, Pneumothorax and Heart Perforation: A Nationwide Population-Based Cohort Study Lin, Yu-Sheng Hung, Sheng-Ping Chen, Pei-Rung Yang, Chia-Hung Wo, Hung-Ta Chang, Po-Cheng Wang, Chun-Chieh Chou, Chung-Chuan Wen, Ming-Shien Chung, Chang-Ming Chen, Tien-Hsing Medicine (Baltimore) 3400 As the number of cardiac implantable electronic devices (CIEDs) is increasing annually, CIED-related complications are becoming increasingly important. The aim of the study was to assess the risks associated with CIEDs by a nationwide database. Patients were selected from the Taiwan National Health Insurance Database. Admissions for CIED implantation, replacement, and revision were evaluated and the evaluation period was 14 years. Endpoints included CIED-related infection, pneumothorax, and heart perforation. The study included 40,608 patients with a mean age of 71.8 ± 13.3 years. Regarding infection, the incidence rate was 2.45 per 1000 CIED-years. Male gender, younger age, device replacement, and previous infection were risks for infection while old age and high-volume centers (>200 per year) were protectors. The incidence of pneumothorax was 0.6%, with an increased risk in individuals who had chronic obstructive lung disease (COPD) and cardiac resynchronized therapy (CRT). The incidence of heart perforation was 0.09%, with an increased risk in individuals who had pre-operation temporal pacing and steroid use. High-volume center was found to decrease infection rate while male gender, young people, and individuals who underwent replacements were associated with an increased risk of infection. Additionally, pre-operation temporal pacing and steroid use should be avoided if possible. Furthermore, COPD patients or those who accept CRTs should be monitored closely. Wolters Kluwer Health 2014-12-12 /pmc/articles/PMC4602772/ /pubmed/25501080 http://dx.doi.org/10.1097/MD.0000000000000213 Text en Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0, where it is permissible to download, share and reproduce the work in any medium, provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle 3400
Lin, Yu-Sheng
Hung, Sheng-Ping
Chen, Pei-Rung
Yang, Chia-Hung
Wo, Hung-Ta
Chang, Po-Cheng
Wang, Chun-Chieh
Chou, Chung-Chuan
Wen, Ming-Shien
Chung, Chang-Ming
Chen, Tien-Hsing
Risk Factors Influencing Complications of Cardiac Implantable Electronic Device Implantation: Infection, Pneumothorax and Heart Perforation: A Nationwide Population-Based Cohort Study
title Risk Factors Influencing Complications of Cardiac Implantable Electronic Device Implantation: Infection, Pneumothorax and Heart Perforation: A Nationwide Population-Based Cohort Study
title_full Risk Factors Influencing Complications of Cardiac Implantable Electronic Device Implantation: Infection, Pneumothorax and Heart Perforation: A Nationwide Population-Based Cohort Study
title_fullStr Risk Factors Influencing Complications of Cardiac Implantable Electronic Device Implantation: Infection, Pneumothorax and Heart Perforation: A Nationwide Population-Based Cohort Study
title_full_unstemmed Risk Factors Influencing Complications of Cardiac Implantable Electronic Device Implantation: Infection, Pneumothorax and Heart Perforation: A Nationwide Population-Based Cohort Study
title_short Risk Factors Influencing Complications of Cardiac Implantable Electronic Device Implantation: Infection, Pneumothorax and Heart Perforation: A Nationwide Population-Based Cohort Study
title_sort risk factors influencing complications of cardiac implantable electronic device implantation: infection, pneumothorax and heart perforation: a nationwide population-based cohort study
topic 3400
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4602772/
https://www.ncbi.nlm.nih.gov/pubmed/25501080
http://dx.doi.org/10.1097/MD.0000000000000213
work_keys_str_mv AT linyusheng riskfactorsinfluencingcomplicationsofcardiacimplantableelectronicdeviceimplantationinfectionpneumothoraxandheartperforationanationwidepopulationbasedcohortstudy
AT hungshengping riskfactorsinfluencingcomplicationsofcardiacimplantableelectronicdeviceimplantationinfectionpneumothoraxandheartperforationanationwidepopulationbasedcohortstudy
AT chenpeirung riskfactorsinfluencingcomplicationsofcardiacimplantableelectronicdeviceimplantationinfectionpneumothoraxandheartperforationanationwidepopulationbasedcohortstudy
AT yangchiahung riskfactorsinfluencingcomplicationsofcardiacimplantableelectronicdeviceimplantationinfectionpneumothoraxandheartperforationanationwidepopulationbasedcohortstudy
AT wohungta riskfactorsinfluencingcomplicationsofcardiacimplantableelectronicdeviceimplantationinfectionpneumothoraxandheartperforationanationwidepopulationbasedcohortstudy
AT changpocheng riskfactorsinfluencingcomplicationsofcardiacimplantableelectronicdeviceimplantationinfectionpneumothoraxandheartperforationanationwidepopulationbasedcohortstudy
AT wangchunchieh riskfactorsinfluencingcomplicationsofcardiacimplantableelectronicdeviceimplantationinfectionpneumothoraxandheartperforationanationwidepopulationbasedcohortstudy
AT chouchungchuan riskfactorsinfluencingcomplicationsofcardiacimplantableelectronicdeviceimplantationinfectionpneumothoraxandheartperforationanationwidepopulationbasedcohortstudy
AT wenmingshien riskfactorsinfluencingcomplicationsofcardiacimplantableelectronicdeviceimplantationinfectionpneumothoraxandheartperforationanationwidepopulationbasedcohortstudy
AT chungchangming riskfactorsinfluencingcomplicationsofcardiacimplantableelectronicdeviceimplantationinfectionpneumothoraxandheartperforationanationwidepopulationbasedcohortstudy
AT chentienhsing riskfactorsinfluencingcomplicationsofcardiacimplantableelectronicdeviceimplantationinfectionpneumothoraxandheartperforationanationwidepopulationbasedcohortstudy