Cargando…

Twenty-Four-Hour Intraocular Pressure Related Changes Following Adjuvant Selective Laser Trabeculoplasty for Normal Tension Glaucoma

To investigate intraocular pressure (IOP) related patterns before and after selective laser trabeculoplasty (SLT) for normal tension glaucoma (NTG). In this prospective cohort study, 18 NTG patients underwent SLT. Success was defined as IOP reduction ≥20% by Goldmann applanation tonometry. 24-hour I...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jacky W.Y., Fu, Lin, Chan, Jonathan C.H., Lai, Jimmy S.M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4602790/
https://www.ncbi.nlm.nih.gov/pubmed/25501089
http://dx.doi.org/10.1097/MD.0000000000000238
_version_ 1782394792593850368
author Lee, Jacky W.Y.
Fu, Lin
Chan, Jonathan C.H.
Lai, Jimmy S.M.
author_facet Lee, Jacky W.Y.
Fu, Lin
Chan, Jonathan C.H.
Lai, Jimmy S.M.
author_sort Lee, Jacky W.Y.
collection PubMed
description To investigate intraocular pressure (IOP) related patterns before and after selective laser trabeculoplasty (SLT) for normal tension glaucoma (NTG). In this prospective cohort study, 18 NTG patients underwent SLT. Success was defined as IOP reduction ≥20% by Goldmann applanation tonometry. 24-hour IOP-related pattern recording with a contact lens sensor (CLS) (SENSIMED Triggerfish(®), Sensimed, Switzerland) was done before (baseline) and 1 month after SLT. A cosine function was fitted to the mean CLS patterns for each individual in the SLT success and non-success groups and the amplitude before and after SLT was calculated. Diurnal, nocturnal, and 24-hour CLS pattern local variability was determined for pre- and post-SLT sessions. Cosine amplitude and variability were compared before and after SLT by group using paired t-tests, with α = 0.05. Patients (11 women, 7 men) had a mean age of 65.1 ± 13.7 years. Mean IOP was 15.3 ± 2.2 mm Hg at baseline and was reduced by 17.0% to 12.7 ± 1.8 mm Hg 1 month after SLT (P = 0.001). SLT was successful in 8 patients (44%). The amplitude of the fitted cosine was reduced by 24.6% in the success group, but displayed an amplitude increase of 19.2% post-SLT in the non-success group. Higher diurnal local variability of the CLS pattern was observed after SLT in non-success subjects (P = 0.002), while nocturnal variability showed no significant change. The increase in diurnal variability in the non-success group led to an increase in 24-hour variability in this group (P = 0.001). No change in local variability (diurnal, nocturnal, and 24-hour) was seen in the success group. The IOP-related pattern cosinor amplitude was reduced in NTG patients with a successful SLT treatment whereas the non-success group exhibited an increase of cosine amplitude. Higher diurnal and 24-hour CLS pattern variability was observed in non-success patients 1 month post-SLT.
format Online
Article
Text
id pubmed-4602790
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-46027902015-10-27 Twenty-Four-Hour Intraocular Pressure Related Changes Following Adjuvant Selective Laser Trabeculoplasty for Normal Tension Glaucoma Lee, Jacky W.Y. Fu, Lin Chan, Jonathan C.H. Lai, Jimmy S.M. Medicine (Baltimore) 5800 To investigate intraocular pressure (IOP) related patterns before and after selective laser trabeculoplasty (SLT) for normal tension glaucoma (NTG). In this prospective cohort study, 18 NTG patients underwent SLT. Success was defined as IOP reduction ≥20% by Goldmann applanation tonometry. 24-hour IOP-related pattern recording with a contact lens sensor (CLS) (SENSIMED Triggerfish(®), Sensimed, Switzerland) was done before (baseline) and 1 month after SLT. A cosine function was fitted to the mean CLS patterns for each individual in the SLT success and non-success groups and the amplitude before and after SLT was calculated. Diurnal, nocturnal, and 24-hour CLS pattern local variability was determined for pre- and post-SLT sessions. Cosine amplitude and variability were compared before and after SLT by group using paired t-tests, with α = 0.05. Patients (11 women, 7 men) had a mean age of 65.1 ± 13.7 years. Mean IOP was 15.3 ± 2.2 mm Hg at baseline and was reduced by 17.0% to 12.7 ± 1.8 mm Hg 1 month after SLT (P = 0.001). SLT was successful in 8 patients (44%). The amplitude of the fitted cosine was reduced by 24.6% in the success group, but displayed an amplitude increase of 19.2% post-SLT in the non-success group. Higher diurnal local variability of the CLS pattern was observed after SLT in non-success subjects (P = 0.002), while nocturnal variability showed no significant change. The increase in diurnal variability in the non-success group led to an increase in 24-hour variability in this group (P = 0.001). No change in local variability (diurnal, nocturnal, and 24-hour) was seen in the success group. The IOP-related pattern cosinor amplitude was reduced in NTG patients with a successful SLT treatment whereas the non-success group exhibited an increase of cosine amplitude. Higher diurnal and 24-hour CLS pattern variability was observed in non-success patients 1 month post-SLT. Wolters Kluwer Health 2014-12-12 /pmc/articles/PMC4602790/ /pubmed/25501089 http://dx.doi.org/10.1097/MD.0000000000000238 Text en Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0
spellingShingle 5800
Lee, Jacky W.Y.
Fu, Lin
Chan, Jonathan C.H.
Lai, Jimmy S.M.
Twenty-Four-Hour Intraocular Pressure Related Changes Following Adjuvant Selective Laser Trabeculoplasty for Normal Tension Glaucoma
title Twenty-Four-Hour Intraocular Pressure Related Changes Following Adjuvant Selective Laser Trabeculoplasty for Normal Tension Glaucoma
title_full Twenty-Four-Hour Intraocular Pressure Related Changes Following Adjuvant Selective Laser Trabeculoplasty for Normal Tension Glaucoma
title_fullStr Twenty-Four-Hour Intraocular Pressure Related Changes Following Adjuvant Selective Laser Trabeculoplasty for Normal Tension Glaucoma
title_full_unstemmed Twenty-Four-Hour Intraocular Pressure Related Changes Following Adjuvant Selective Laser Trabeculoplasty for Normal Tension Glaucoma
title_short Twenty-Four-Hour Intraocular Pressure Related Changes Following Adjuvant Selective Laser Trabeculoplasty for Normal Tension Glaucoma
title_sort twenty-four-hour intraocular pressure related changes following adjuvant selective laser trabeculoplasty for normal tension glaucoma
topic 5800
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4602790/
https://www.ncbi.nlm.nih.gov/pubmed/25501089
http://dx.doi.org/10.1097/MD.0000000000000238
work_keys_str_mv AT leejackywy twentyfourhourintraocularpressurerelatedchangesfollowingadjuvantselectivelasertrabeculoplastyfornormaltensionglaucoma
AT fulin twentyfourhourintraocularpressurerelatedchangesfollowingadjuvantselectivelasertrabeculoplastyfornormaltensionglaucoma
AT chanjonathanch twentyfourhourintraocularpressurerelatedchangesfollowingadjuvantselectivelasertrabeculoplastyfornormaltensionglaucoma
AT laijimmysm twentyfourhourintraocularpressurerelatedchangesfollowingadjuvantselectivelasertrabeculoplastyfornormaltensionglaucoma