Cargando…

Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-compliant article

Reliable osteosynthesis of intraarticular fractures depends on lasting interfragmentary compression. Its amount differs in the applied fixation method. The interfragmentary compression of cancellous and cortical lag screws and angle stable locking plates was quantified in an osteoporotic and non-ost...

Descripción completa

Detalles Bibliográficos
Autores principales: Kojima, K., Gueorguiev, B., Seva, G., Stoffel, K., de Oliveira, R. Garcia, Eberli, U., Nicolino, T., Lenz, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4602845/
https://www.ncbi.nlm.nih.gov/pubmed/25569643
http://dx.doi.org/10.1097/MD.0000000000000282
_version_ 1782394805074001920
author Kojima, K.
Gueorguiev, B.
Seva, G.
Stoffel, K.
de Oliveira, R. Garcia
Eberli, U.
Nicolino, T.
Lenz, M.
author_facet Kojima, K.
Gueorguiev, B.
Seva, G.
Stoffel, K.
de Oliveira, R. Garcia
Eberli, U.
Nicolino, T.
Lenz, M.
author_sort Kojima, K.
collection PubMed
description Reliable osteosynthesis of intraarticular fractures depends on lasting interfragmentary compression. Its amount differs in the applied fixation method. The interfragmentary compression of cancellous and cortical lag screws and angle stable locking plates was quantified in an osteoporotic and non-osteoporotic synthetic human bone model. A split fracture of the lateral tibia plateau (AO/OTA type 41-B1.1) was mimicked by an osteotomy in right adult synthetic human tibiae with hard or soft cancellous bone. Specimens were fixed with either two 6.5 mm cancellous, four 3.5 mm cortical lag screws, or 3.5 mm LCP proximal lateral tibia plate preliminary compresed by a reduction clamp (n = 5 per group). A pressure sensor film was used to register the interfragmentary compression. One-way analysis of variance (ANOVA) with Bonferroni post hoc correction was performed for statistical analysis (p < 0.05). Interfragmentary compression under reduction clamp was 0.59 ± 0.12 MPa in the non-osteoporotic and 0.55 ± 0.14 MPa in the osteoporotic group. The locking plate itself maintained the compression in non-osteoporotic (0.53 ± 0.11 MPa) and osteoporotic bone (0.50 ± 0.14 MPa). Four 3.5 mm cortical lag screws provided a compression of 1.69 ± 0.65 MPa in non-osteoporotic bone, being not significantly different to the osteoporotic bone group (1.43 ± 0.47 MPa, P = 1.0). Two 6.5 mm cancellous lag screws showed a significantly higher compression in non-osteoporotic (2.1 ± 0.59 MPa) compared to osteoporotic (0.77 ± 0.21 MPa, P < 0.01) bone. Angle stable locking plates maintained the compression preliminarily applied by a reduction clamp. Two 6.5 mm cancellous lag screws are especially suited for non-osteoporotic bone, whereas four 3.5 mm cortical screws exhibited comparable compression in both bone qualities.
format Online
Article
Text
id pubmed-4602845
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-46028452015-10-27 Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-compliant article Kojima, K. Gueorguiev, B. Seva, G. Stoffel, K. de Oliveira, R. Garcia Eberli, U. Nicolino, T. Lenz, M. Medicine (Baltimore) 7100 Reliable osteosynthesis of intraarticular fractures depends on lasting interfragmentary compression. Its amount differs in the applied fixation method. The interfragmentary compression of cancellous and cortical lag screws and angle stable locking plates was quantified in an osteoporotic and non-osteoporotic synthetic human bone model. A split fracture of the lateral tibia plateau (AO/OTA type 41-B1.1) was mimicked by an osteotomy in right adult synthetic human tibiae with hard or soft cancellous bone. Specimens were fixed with either two 6.5 mm cancellous, four 3.5 mm cortical lag screws, or 3.5 mm LCP proximal lateral tibia plate preliminary compresed by a reduction clamp (n = 5 per group). A pressure sensor film was used to register the interfragmentary compression. One-way analysis of variance (ANOVA) with Bonferroni post hoc correction was performed for statistical analysis (p < 0.05). Interfragmentary compression under reduction clamp was 0.59 ± 0.12 MPa in the non-osteoporotic and 0.55 ± 0.14 MPa in the osteoporotic group. The locking plate itself maintained the compression in non-osteoporotic (0.53 ± 0.11 MPa) and osteoporotic bone (0.50 ± 0.14 MPa). Four 3.5 mm cortical lag screws provided a compression of 1.69 ± 0.65 MPa in non-osteoporotic bone, being not significantly different to the osteoporotic bone group (1.43 ± 0.47 MPa, P = 1.0). Two 6.5 mm cancellous lag screws showed a significantly higher compression in non-osteoporotic (2.1 ± 0.59 MPa) compared to osteoporotic (0.77 ± 0.21 MPa, P < 0.01) bone. Angle stable locking plates maintained the compression preliminarily applied by a reduction clamp. Two 6.5 mm cancellous lag screws are especially suited for non-osteoporotic bone, whereas four 3.5 mm cortical screws exhibited comparable compression in both bone qualities. Wolters Kluwer Health 2015-01-09 /pmc/articles/PMC4602845/ /pubmed/25569643 http://dx.doi.org/10.1097/MD.0000000000000282 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0, where it is permissible to download, share and reproduce the work in any medium, provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle 7100
Kojima, K.
Gueorguiev, B.
Seva, G.
Stoffel, K.
de Oliveira, R. Garcia
Eberli, U.
Nicolino, T.
Lenz, M.
Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-compliant article
title Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-compliant article
title_full Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-compliant article
title_fullStr Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-compliant article
title_full_unstemmed Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-compliant article
title_short Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-compliant article
title_sort biomechanical evaluation of interfragmentary compression at tibia plateau fractures in vitro using different fixation techniques: a consort-compliant article
topic 7100
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4602845/
https://www.ncbi.nlm.nih.gov/pubmed/25569643
http://dx.doi.org/10.1097/MD.0000000000000282
work_keys_str_mv AT kojimak biomechanicalevaluationofinterfragmentarycompressionattibiaplateaufracturesinvitrousingdifferentfixationtechniquesaconsortcompliantarticle
AT gueorguievb biomechanicalevaluationofinterfragmentarycompressionattibiaplateaufracturesinvitrousingdifferentfixationtechniquesaconsortcompliantarticle
AT sevag biomechanicalevaluationofinterfragmentarycompressionattibiaplateaufracturesinvitrousingdifferentfixationtechniquesaconsortcompliantarticle
AT stoffelk biomechanicalevaluationofinterfragmentarycompressionattibiaplateaufracturesinvitrousingdifferentfixationtechniquesaconsortcompliantarticle
AT deoliveirargarcia biomechanicalevaluationofinterfragmentarycompressionattibiaplateaufracturesinvitrousingdifferentfixationtechniquesaconsortcompliantarticle
AT eberliu biomechanicalevaluationofinterfragmentarycompressionattibiaplateaufracturesinvitrousingdifferentfixationtechniquesaconsortcompliantarticle
AT nicolinot biomechanicalevaluationofinterfragmentarycompressionattibiaplateaufracturesinvitrousingdifferentfixationtechniquesaconsortcompliantarticle
AT lenzm biomechanicalevaluationofinterfragmentarycompressionattibiaplateaufracturesinvitrousingdifferentfixationtechniquesaconsortcompliantarticle