Cargando…
Reliability and validity of ten consumer activity trackers
BACKGROUND: Activity trackers can potentially stimulate users to increase their physical activity behavior. The aim of this study was to examine the reliability and validity of ten consumer activity trackers for measuring step count in both laboratory and free-living conditions. METHOD: Healthy adul...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4603296/ https://www.ncbi.nlm.nih.gov/pubmed/26464801 http://dx.doi.org/10.1186/s13102-015-0018-5 |
_version_ | 1782394889764339712 |
---|---|
author | Kooiman, Thea J. M. Dontje, Manon L. Sprenger, Siska R. Krijnen, Wim P. van der Schans, Cees P. de Groot, Martijn |
author_facet | Kooiman, Thea J. M. Dontje, Manon L. Sprenger, Siska R. Krijnen, Wim P. van der Schans, Cees P. de Groot, Martijn |
author_sort | Kooiman, Thea J. M. |
collection | PubMed |
description | BACKGROUND: Activity trackers can potentially stimulate users to increase their physical activity behavior. The aim of this study was to examine the reliability and validity of ten consumer activity trackers for measuring step count in both laboratory and free-living conditions. METHOD: Healthy adult volunteers (n = 33) walked twice on a treadmill (4.8 km/h) for 30 min while wearing ten different activity trackers (i.e. Lumoback, Fitbit Flex, Jawbone Up, Nike+ Fuelband SE, Misfit Shine, Withings Pulse, Fitbit Zip, Omron HJ-203, Yamax Digiwalker SW-200 and Moves mobile application). In free-living conditions, 56 volunteers wore the same activity trackers for one working day. Test-retest reliability was analyzed with the Intraclass Correlation Coefficient (ICC). Validity was evaluated by comparing each tracker with the gold standard (Optogait system for laboratory and ActivPAL for free-living conditions), using paired samples t-tests, mean absolute percentage errors, correlations and Bland-Altman plots. RESULTS: Test-retest analysis revealed high reliability for most trackers except for the Omron (ICC .14), Moves app (ICC .37) and Nike+ Fuelband (ICC .53). The mean absolute percentage errors of the trackers in laboratory and free-living conditions respectively, were: Lumoback (−0.2, −0.4), Fibit Flex (−5.7, 3.7), Jawbone Up (−1.0, 1.4), Nike+ Fuelband (−18, −24), Misfit Shine (0.2, 1.1), Withings Pulse (−0.5, −7.9), Fitbit Zip (−0.3, 1.2), Omron (2.5, −0.4), Digiwalker (−1.2, −5.9), and Moves app (9.6, −37.6). Bland-Altman plots demonstrated that the limits of agreement varied from 46 steps (Fitbit Zip) to 2422 steps (Nike+ Fuelband) in the laboratory condition, and 866 steps (Fitbit Zip) to 5150 steps (Moves app) in the free-living condition. CONCLUSION: The reliability and validity of most trackers for measuring step count is good. The Fitbit Zip is the most valid whereas the reliability and validity of the Nike+ Fuelband is low. |
format | Online Article Text |
id | pubmed-4603296 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-46032962015-10-14 Reliability and validity of ten consumer activity trackers Kooiman, Thea J. M. Dontje, Manon L. Sprenger, Siska R. Krijnen, Wim P. van der Schans, Cees P. de Groot, Martijn BMC Sports Sci Med Rehabil Research Article BACKGROUND: Activity trackers can potentially stimulate users to increase their physical activity behavior. The aim of this study was to examine the reliability and validity of ten consumer activity trackers for measuring step count in both laboratory and free-living conditions. METHOD: Healthy adult volunteers (n = 33) walked twice on a treadmill (4.8 km/h) for 30 min while wearing ten different activity trackers (i.e. Lumoback, Fitbit Flex, Jawbone Up, Nike+ Fuelband SE, Misfit Shine, Withings Pulse, Fitbit Zip, Omron HJ-203, Yamax Digiwalker SW-200 and Moves mobile application). In free-living conditions, 56 volunteers wore the same activity trackers for one working day. Test-retest reliability was analyzed with the Intraclass Correlation Coefficient (ICC). Validity was evaluated by comparing each tracker with the gold standard (Optogait system for laboratory and ActivPAL for free-living conditions), using paired samples t-tests, mean absolute percentage errors, correlations and Bland-Altman plots. RESULTS: Test-retest analysis revealed high reliability for most trackers except for the Omron (ICC .14), Moves app (ICC .37) and Nike+ Fuelband (ICC .53). The mean absolute percentage errors of the trackers in laboratory and free-living conditions respectively, were: Lumoback (−0.2, −0.4), Fibit Flex (−5.7, 3.7), Jawbone Up (−1.0, 1.4), Nike+ Fuelband (−18, −24), Misfit Shine (0.2, 1.1), Withings Pulse (−0.5, −7.9), Fitbit Zip (−0.3, 1.2), Omron (2.5, −0.4), Digiwalker (−1.2, −5.9), and Moves app (9.6, −37.6). Bland-Altman plots demonstrated that the limits of agreement varied from 46 steps (Fitbit Zip) to 2422 steps (Nike+ Fuelband) in the laboratory condition, and 866 steps (Fitbit Zip) to 5150 steps (Moves app) in the free-living condition. CONCLUSION: The reliability and validity of most trackers for measuring step count is good. The Fitbit Zip is the most valid whereas the reliability and validity of the Nike+ Fuelband is low. BioMed Central 2015-10-12 /pmc/articles/PMC4603296/ /pubmed/26464801 http://dx.doi.org/10.1186/s13102-015-0018-5 Text en © Kooiman et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Kooiman, Thea J. M. Dontje, Manon L. Sprenger, Siska R. Krijnen, Wim P. van der Schans, Cees P. de Groot, Martijn Reliability and validity of ten consumer activity trackers |
title | Reliability and validity of ten consumer activity trackers |
title_full | Reliability and validity of ten consumer activity trackers |
title_fullStr | Reliability and validity of ten consumer activity trackers |
title_full_unstemmed | Reliability and validity of ten consumer activity trackers |
title_short | Reliability and validity of ten consumer activity trackers |
title_sort | reliability and validity of ten consumer activity trackers |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4603296/ https://www.ncbi.nlm.nih.gov/pubmed/26464801 http://dx.doi.org/10.1186/s13102-015-0018-5 |
work_keys_str_mv | AT kooimantheajm reliabilityandvalidityoftenconsumeractivitytrackers AT dontjemanonl reliabilityandvalidityoftenconsumeractivitytrackers AT sprengersiskar reliabilityandvalidityoftenconsumeractivitytrackers AT krijnenwimp reliabilityandvalidityoftenconsumeractivitytrackers AT vanderschansceesp reliabilityandvalidityoftenconsumeractivitytrackers AT degrootmartijn reliabilityandvalidityoftenconsumeractivitytrackers |