True Unipolar ECG Machine for Wilson Central Terminal Measurements
Since its invention (more than 80 years ago), modern electrocardiography has employed a supposedly stable voltage reference (with little variation during the cardiac cycle) for half of the signals. This reference, known by the name of “Wilson Central Terminal” in honor of its inventor, is obtained b...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4606145/ https://www.ncbi.nlm.nih.gov/pubmed/26495303 http://dx.doi.org/10.1155/2015/586397 |
_version_ | 1782395322719272960 |
---|---|
author | Gargiulo, Gaetano D. |
author_facet | Gargiulo, Gaetano D. |
author_sort | Gargiulo, Gaetano D. |
collection | PubMed |
description | Since its invention (more than 80 years ago), modern electrocardiography has employed a supposedly stable voltage reference (with little variation during the cardiac cycle) for half of the signals. This reference, known by the name of “Wilson Central Terminal” in honor of its inventor, is obtained by averaging the three active limb electrode voltages measured with respect to the return ground electrode. However, concerns have been raised by researchers about problems (biasing and misdiagnosis) associated with the ambiguous value and behavior of this reference voltage, which requires perfect and balanced contact of at least four electrodes to work properly. The Wilson Central Terminal has received scant research attention in the last few decades even though consideration of recent widespread medical practice (limb electrodes are repositioned closer to the torso for resting electrocardiography) has also sparkled concerns about the validity and diagnostic fitness of leads not referred to the Wilson Central Terminal. Using a true unipolar electrocardiography device capable of precisely measuring the Wilson Central Terminal, we show its unpredictable variability during the cardiac cycle and confirm that the integrity of cardinal leads is compromised as well as the Wilson Central Terminal when limb electrodes are placed close to the torso. |
format | Online Article Text |
id | pubmed-4606145 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-46061452015-10-22 True Unipolar ECG Machine for Wilson Central Terminal Measurements Gargiulo, Gaetano D. Biomed Res Int Research Article Since its invention (more than 80 years ago), modern electrocardiography has employed a supposedly stable voltage reference (with little variation during the cardiac cycle) for half of the signals. This reference, known by the name of “Wilson Central Terminal” in honor of its inventor, is obtained by averaging the three active limb electrode voltages measured with respect to the return ground electrode. However, concerns have been raised by researchers about problems (biasing and misdiagnosis) associated with the ambiguous value and behavior of this reference voltage, which requires perfect and balanced contact of at least four electrodes to work properly. The Wilson Central Terminal has received scant research attention in the last few decades even though consideration of recent widespread medical practice (limb electrodes are repositioned closer to the torso for resting electrocardiography) has also sparkled concerns about the validity and diagnostic fitness of leads not referred to the Wilson Central Terminal. Using a true unipolar electrocardiography device capable of precisely measuring the Wilson Central Terminal, we show its unpredictable variability during the cardiac cycle and confirm that the integrity of cardinal leads is compromised as well as the Wilson Central Terminal when limb electrodes are placed close to the torso. Hindawi Publishing Corporation 2015 2015-10-01 /pmc/articles/PMC4606145/ /pubmed/26495303 http://dx.doi.org/10.1155/2015/586397 Text en Copyright © 2015 Gaetano D. Gargiulo. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Gargiulo, Gaetano D. True Unipolar ECG Machine for Wilson Central Terminal Measurements |
title | True Unipolar ECG Machine for Wilson Central Terminal Measurements |
title_full | True Unipolar ECG Machine for Wilson Central Terminal Measurements |
title_fullStr | True Unipolar ECG Machine for Wilson Central Terminal Measurements |
title_full_unstemmed | True Unipolar ECG Machine for Wilson Central Terminal Measurements |
title_short | True Unipolar ECG Machine for Wilson Central Terminal Measurements |
title_sort | true unipolar ecg machine for wilson central terminal measurements |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4606145/ https://www.ncbi.nlm.nih.gov/pubmed/26495303 http://dx.doi.org/10.1155/2015/586397 |
work_keys_str_mv | AT gargiulogaetanod trueunipolarecgmachineforwilsoncentralterminalmeasurements |