Cargando…
Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth
The standard-of-care guidelines published by the American Society of Anesthesiologists (ASA) recommend monitoring of pulse oximetry, blood pressure, heart rate, and end tidal CO(2) during the use of anesthesia and sedation. This information can help to identify adverse events that may occur during p...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4606411/ https://www.ncbi.nlm.nih.gov/pubmed/26495317 http://dx.doi.org/10.1155/2015/939418 |
_version_ | 1782395346366758912 |
---|---|
author | Hernandez-Meza, Gabriela Izzetoglu, Meltem Osbakken, Mary Green, Michael Izzetoglu, Kurtulus |
author_facet | Hernandez-Meza, Gabriela Izzetoglu, Meltem Osbakken, Mary Green, Michael Izzetoglu, Kurtulus |
author_sort | Hernandez-Meza, Gabriela |
collection | PubMed |
description | The standard-of-care guidelines published by the American Society of Anesthesiologists (ASA) recommend monitoring of pulse oximetry, blood pressure, heart rate, and end tidal CO(2) during the use of anesthesia and sedation. This information can help to identify adverse events that may occur during procedures. However, these parameters are not specific to the effects of anesthetics or sedatives, and therefore they offer little, to no, real time information regarding the effects of those agents and do not give the clinician the lead-time necessary to prevent patient “awareness.” Since no “gold-standard” method is available to continuously, reliably, and effectively monitor the effects of sedatives and anesthetics, such a method is greatly needed. Investigation of the use of functional near-infrared spectroscopy (fNIRS) as a method for anesthesia or sedation monitoring and for the assessment of the effects of various anesthetic drugs on cerebral oxygenation has started to be conducted. The objective of this paper is to provide a thorough review of the currently available published scientific studies regarding the use of fNIRS in the fields of anesthesia and sedation monitoring, comment on their findings, and discuss the future work required for the translation of this technology to the clinical setting. |
format | Online Article Text |
id | pubmed-4606411 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-46064112015-10-22 Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth Hernandez-Meza, Gabriela Izzetoglu, Meltem Osbakken, Mary Green, Michael Izzetoglu, Kurtulus Biomed Res Int Review Article The standard-of-care guidelines published by the American Society of Anesthesiologists (ASA) recommend monitoring of pulse oximetry, blood pressure, heart rate, and end tidal CO(2) during the use of anesthesia and sedation. This information can help to identify adverse events that may occur during procedures. However, these parameters are not specific to the effects of anesthetics or sedatives, and therefore they offer little, to no, real time information regarding the effects of those agents and do not give the clinician the lead-time necessary to prevent patient “awareness.” Since no “gold-standard” method is available to continuously, reliably, and effectively monitor the effects of sedatives and anesthetics, such a method is greatly needed. Investigation of the use of functional near-infrared spectroscopy (fNIRS) as a method for anesthesia or sedation monitoring and for the assessment of the effects of various anesthetic drugs on cerebral oxygenation has started to be conducted. The objective of this paper is to provide a thorough review of the currently available published scientific studies regarding the use of fNIRS in the fields of anesthesia and sedation monitoring, comment on their findings, and discuss the future work required for the translation of this technology to the clinical setting. Hindawi Publishing Corporation 2015 2015-10-01 /pmc/articles/PMC4606411/ /pubmed/26495317 http://dx.doi.org/10.1155/2015/939418 Text en Copyright © 2015 Gabriela Hernandez-Meza et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Hernandez-Meza, Gabriela Izzetoglu, Meltem Osbakken, Mary Green, Michael Izzetoglu, Kurtulus Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth |
title | Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth |
title_full | Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth |
title_fullStr | Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth |
title_full_unstemmed | Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth |
title_short | Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth |
title_sort | near-infrared spectroscopy for the evaluation of anesthetic depth |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4606411/ https://www.ncbi.nlm.nih.gov/pubmed/26495317 http://dx.doi.org/10.1155/2015/939418 |
work_keys_str_mv | AT hernandezmezagabriela nearinfraredspectroscopyfortheevaluationofanestheticdepth AT izzetoglumeltem nearinfraredspectroscopyfortheevaluationofanestheticdepth AT osbakkenmary nearinfraredspectroscopyfortheevaluationofanestheticdepth AT greenmichael nearinfraredspectroscopyfortheevaluationofanestheticdepth AT izzetoglukurtulus nearinfraredspectroscopyfortheevaluationofanestheticdepth |