Cargando…

Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth

The standard-of-care guidelines published by the American Society of Anesthesiologists (ASA) recommend monitoring of pulse oximetry, blood pressure, heart rate, and end tidal CO(2) during the use of anesthesia and sedation. This information can help to identify adverse events that may occur during p...

Descripción completa

Detalles Bibliográficos
Autores principales: Hernandez-Meza, Gabriela, Izzetoglu, Meltem, Osbakken, Mary, Green, Michael, Izzetoglu, Kurtulus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4606411/
https://www.ncbi.nlm.nih.gov/pubmed/26495317
http://dx.doi.org/10.1155/2015/939418
_version_ 1782395346366758912
author Hernandez-Meza, Gabriela
Izzetoglu, Meltem
Osbakken, Mary
Green, Michael
Izzetoglu, Kurtulus
author_facet Hernandez-Meza, Gabriela
Izzetoglu, Meltem
Osbakken, Mary
Green, Michael
Izzetoglu, Kurtulus
author_sort Hernandez-Meza, Gabriela
collection PubMed
description The standard-of-care guidelines published by the American Society of Anesthesiologists (ASA) recommend monitoring of pulse oximetry, blood pressure, heart rate, and end tidal CO(2) during the use of anesthesia and sedation. This information can help to identify adverse events that may occur during procedures. However, these parameters are not specific to the effects of anesthetics or sedatives, and therefore they offer little, to no, real time information regarding the effects of those agents and do not give the clinician the lead-time necessary to prevent patient “awareness.” Since no “gold-standard” method is available to continuously, reliably, and effectively monitor the effects of sedatives and anesthetics, such a method is greatly needed. Investigation of the use of functional near-infrared spectroscopy (fNIRS) as a method for anesthesia or sedation monitoring and for the assessment of the effects of various anesthetic drugs on cerebral oxygenation has started to be conducted. The objective of this paper is to provide a thorough review of the currently available published scientific studies regarding the use of fNIRS in the fields of anesthesia and sedation monitoring, comment on their findings, and discuss the future work required for the translation of this technology to the clinical setting.
format Online
Article
Text
id pubmed-4606411
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-46064112015-10-22 Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth Hernandez-Meza, Gabriela Izzetoglu, Meltem Osbakken, Mary Green, Michael Izzetoglu, Kurtulus Biomed Res Int Review Article The standard-of-care guidelines published by the American Society of Anesthesiologists (ASA) recommend monitoring of pulse oximetry, blood pressure, heart rate, and end tidal CO(2) during the use of anesthesia and sedation. This information can help to identify adverse events that may occur during procedures. However, these parameters are not specific to the effects of anesthetics or sedatives, and therefore they offer little, to no, real time information regarding the effects of those agents and do not give the clinician the lead-time necessary to prevent patient “awareness.” Since no “gold-standard” method is available to continuously, reliably, and effectively monitor the effects of sedatives and anesthetics, such a method is greatly needed. Investigation of the use of functional near-infrared spectroscopy (fNIRS) as a method for anesthesia or sedation monitoring and for the assessment of the effects of various anesthetic drugs on cerebral oxygenation has started to be conducted. The objective of this paper is to provide a thorough review of the currently available published scientific studies regarding the use of fNIRS in the fields of anesthesia and sedation monitoring, comment on their findings, and discuss the future work required for the translation of this technology to the clinical setting. Hindawi Publishing Corporation 2015 2015-10-01 /pmc/articles/PMC4606411/ /pubmed/26495317 http://dx.doi.org/10.1155/2015/939418 Text en Copyright © 2015 Gabriela Hernandez-Meza et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Hernandez-Meza, Gabriela
Izzetoglu, Meltem
Osbakken, Mary
Green, Michael
Izzetoglu, Kurtulus
Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth
title Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth
title_full Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth
title_fullStr Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth
title_full_unstemmed Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth
title_short Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth
title_sort near-infrared spectroscopy for the evaluation of anesthetic depth
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4606411/
https://www.ncbi.nlm.nih.gov/pubmed/26495317
http://dx.doi.org/10.1155/2015/939418
work_keys_str_mv AT hernandezmezagabriela nearinfraredspectroscopyfortheevaluationofanestheticdepth
AT izzetoglumeltem nearinfraredspectroscopyfortheevaluationofanestheticdepth
AT osbakkenmary nearinfraredspectroscopyfortheevaluationofanestheticdepth
AT greenmichael nearinfraredspectroscopyfortheevaluationofanestheticdepth
AT izzetoglukurtulus nearinfraredspectroscopyfortheevaluationofanestheticdepth