Cargando…

Plasma preparation to measure FDA-approved protein markers by selected reaction monitoring

BACKGROUND: The development of commercially available panels for human blood plasma screening via selected reaction monitoring (SRM) offers reliable, cost-efficient and highly-standardized discovery and validation of protein biomarkers. However, protein detection by SRM can be hampered by interferin...

Descripción completa

Detalles Bibliográficos
Autores principales: Kiseleva, Olga I., Romashova, Yulia A., Moskaleva, Natalia E., Petushkova, Natalia A., Teryaeva, Nadezhda B., Belyaev, Artem Yu., Lisitsa, Andrey V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4607682/
https://www.ncbi.nlm.nih.gov/pubmed/26471814
http://dx.doi.org/10.1186/s40169-015-0071-4
_version_ 1782395538992267264
author Kiseleva, Olga I.
Romashova, Yulia A.
Moskaleva, Natalia E.
Petushkova, Natalia A.
Teryaeva, Nadezhda B.
Belyaev, Artem Yu.
Lisitsa, Andrey V.
author_facet Kiseleva, Olga I.
Romashova, Yulia A.
Moskaleva, Natalia E.
Petushkova, Natalia A.
Teryaeva, Nadezhda B.
Belyaev, Artem Yu.
Lisitsa, Andrey V.
author_sort Kiseleva, Olga I.
collection PubMed
description BACKGROUND: The development of commercially available panels for human blood plasma screening via selected reaction monitoring (SRM) offers reliable, cost-efficient and highly-standardized discovery and validation of protein biomarkers. However, protein detection by SRM can be hampered by interfering peptide fragment ions. To estimate the influence of interference on protein detection, we performed different types of sample preparation and implemented SRM measurements for well-characterized protein targets approved by the US Food and Drug Administration. METHODS: We used the PlasmaDeepDive™ SRM assay from BiognoSYS AG for absolute quantification of 18 proteins in 19 samples of human plasma using three different protocols for sample preparation. SRM measurements were performed using iRT standards for retention time normalization and isotopically-labeled reference peptides for absolute quantification. SpectroDive™ software was used for automated detection of reliable peak groups. RESULTS: Fourteen targeted proteins were quantitatively measured in more than half of the samples. Depletion of highly-abundant plasma proteins and peptide fraction clean-up on centrifuge plates resulted in detection of all 18 targeted proteins in femtomolar to picomolar concentrations. CONCLUSIONS: It was shown that commercially designed SRM kits are suitable for SRM detection of well-established plasma/serum biomarkers. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s40169-015-0071-4) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4607682
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-46076822015-10-21 Plasma preparation to measure FDA-approved protein markers by selected reaction monitoring Kiseleva, Olga I. Romashova, Yulia A. Moskaleva, Natalia E. Petushkova, Natalia A. Teryaeva, Nadezhda B. Belyaev, Artem Yu. Lisitsa, Andrey V. Clin Transl Med Short Report BACKGROUND: The development of commercially available panels for human blood plasma screening via selected reaction monitoring (SRM) offers reliable, cost-efficient and highly-standardized discovery and validation of protein biomarkers. However, protein detection by SRM can be hampered by interfering peptide fragment ions. To estimate the influence of interference on protein detection, we performed different types of sample preparation and implemented SRM measurements for well-characterized protein targets approved by the US Food and Drug Administration. METHODS: We used the PlasmaDeepDive™ SRM assay from BiognoSYS AG for absolute quantification of 18 proteins in 19 samples of human plasma using three different protocols for sample preparation. SRM measurements were performed using iRT standards for retention time normalization and isotopically-labeled reference peptides for absolute quantification. SpectroDive™ software was used for automated detection of reliable peak groups. RESULTS: Fourteen targeted proteins were quantitatively measured in more than half of the samples. Depletion of highly-abundant plasma proteins and peptide fraction clean-up on centrifuge plates resulted in detection of all 18 targeted proteins in femtomolar to picomolar concentrations. CONCLUSIONS: It was shown that commercially designed SRM kits are suitable for SRM detection of well-established plasma/serum biomarkers. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s40169-015-0071-4) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2015-10-15 /pmc/articles/PMC4607682/ /pubmed/26471814 http://dx.doi.org/10.1186/s40169-015-0071-4 Text en © Kiseleva et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Short Report
Kiseleva, Olga I.
Romashova, Yulia A.
Moskaleva, Natalia E.
Petushkova, Natalia A.
Teryaeva, Nadezhda B.
Belyaev, Artem Yu.
Lisitsa, Andrey V.
Plasma preparation to measure FDA-approved protein markers by selected reaction monitoring
title Plasma preparation to measure FDA-approved protein markers by selected reaction monitoring
title_full Plasma preparation to measure FDA-approved protein markers by selected reaction monitoring
title_fullStr Plasma preparation to measure FDA-approved protein markers by selected reaction monitoring
title_full_unstemmed Plasma preparation to measure FDA-approved protein markers by selected reaction monitoring
title_short Plasma preparation to measure FDA-approved protein markers by selected reaction monitoring
title_sort plasma preparation to measure fda-approved protein markers by selected reaction monitoring
topic Short Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4607682/
https://www.ncbi.nlm.nih.gov/pubmed/26471814
http://dx.doi.org/10.1186/s40169-015-0071-4
work_keys_str_mv AT kiselevaolgai plasmapreparationtomeasurefdaapprovedproteinmarkersbyselectedreactionmonitoring
AT romashovayuliaa plasmapreparationtomeasurefdaapprovedproteinmarkersbyselectedreactionmonitoring
AT moskalevanataliae plasmapreparationtomeasurefdaapprovedproteinmarkersbyselectedreactionmonitoring
AT petushkovanataliaa plasmapreparationtomeasurefdaapprovedproteinmarkersbyselectedreactionmonitoring
AT teryaevanadezhdab plasmapreparationtomeasurefdaapprovedproteinmarkersbyselectedreactionmonitoring
AT belyaevartemyu plasmapreparationtomeasurefdaapprovedproteinmarkersbyselectedreactionmonitoring
AT lisitsaandreyv plasmapreparationtomeasurefdaapprovedproteinmarkersbyselectedreactionmonitoring