Cargando…

Percutaneous closure of patent arterial ducts in patients from high altitude: a sub-Saharan experience

BACKGROUND: At high altitude, patent arterial ducts tend to be larger and associated with pulmonary hypertension. Patent ductus arteriosus device closure in this background could be challenging. OBJECTIVES: We report our experience with percutaneous closure of patent arterial ducts using a variety o...

Descripción completa

Detalles Bibliográficos
Autores principales: Tefera, Endale, Qureshi, Shakeel A, Bermudez-Cañete, Ramòn, Rubio, Lola
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4608196/
https://www.ncbi.nlm.nih.gov/pubmed/26556965
http://dx.doi.org/10.4103/0974-2069.164690
_version_ 1782395630169096192
author Tefera, Endale
Qureshi, Shakeel A
Bermudez-Cañete, Ramòn
Rubio, Lola
author_facet Tefera, Endale
Qureshi, Shakeel A
Bermudez-Cañete, Ramòn
Rubio, Lola
author_sort Tefera, Endale
collection PubMed
description BACKGROUND: At high altitude, patent arterial ducts tend to be larger and associated with pulmonary hypertension. Patent ductus arteriosus device closure in this background could be challenging. OBJECTIVES: We report our experience with percutaneous closure of patent arterial ducts using a variety of devices in patients residing in a high altitude. PATIENTS AND METHODS: This is a retrospective review of the case records of 145 patients (age 9 months-20 years, mean 5.6 ± 3.9 years, and weight 7-54 kg, mean 17.7 ± 9.4) with duct sizes ranging between 2 and 21 mm, (mean, 5.8 ± 2.7) who underwent percutaneous closure of patent arterial ducts. One hundred thirty-six (93.8%) of the patients were from a geographic area of 2100-2800 m above sea level. RESULTS: Successful device closure was achieved in 143 cases. It was difficult to achieve device stability in two patients with expansile ducts. Therefore, they were treated surgically. The devices used were various types of duct occluder devices in 131 patients, while atrial and ventricular septal occluders were used in eight patients. For the group, mean systolic pulmonary artery (PA) pressure decreased from 47.0 ± 16.7 mmHg before occlusion to 29.0 ± 7.4 mmHg after occlusion (P ≤ 0.001)., mean diastolic PA pressure from 25.0 ± 10.9 mmHg to 14.8 ± 6.0 mmHg and the average mean PA pressure decreased from 35.9 ± 13.5 mmHg to 21.1 ± 6.5 mmHg. Complications (4.8%) included device and coil embolization, bleeding, and pulse loss. On follow-up (mean duration of 36.1 ± 12.1 months, range 12-62 months), 137 patients were in functional class 1, 3 had residual shunt, 2 had device migration and one patient had persisting pulse loss. CONCLUSIONS: Successful duct closure was achieved in the vast majority of patients, even though the ducts were larger and significant number of them had pulmonary hypertension in this high altitude group. There was a relatively higher incidence of residual shunts and device migration in this series, generally due to the nonavailability of optimal device and surgical support. Long-term follow-up is required before we can draw conclusions with regard to the sustainability of drop in PA pressures. Septal Occluder devices may be a possible alternative for large tubular or window-type ducts with severe pulmonary hypertension, where there may be concerns about the size and stability of duct occluder devices.
format Online
Article
Text
id pubmed-4608196
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-46081962015-11-09 Percutaneous closure of patent arterial ducts in patients from high altitude: a sub-Saharan experience Tefera, Endale Qureshi, Shakeel A Bermudez-Cañete, Ramòn Rubio, Lola Ann Pediatr Cardiol Original Article BACKGROUND: At high altitude, patent arterial ducts tend to be larger and associated with pulmonary hypertension. Patent ductus arteriosus device closure in this background could be challenging. OBJECTIVES: We report our experience with percutaneous closure of patent arterial ducts using a variety of devices in patients residing in a high altitude. PATIENTS AND METHODS: This is a retrospective review of the case records of 145 patients (age 9 months-20 years, mean 5.6 ± 3.9 years, and weight 7-54 kg, mean 17.7 ± 9.4) with duct sizes ranging between 2 and 21 mm, (mean, 5.8 ± 2.7) who underwent percutaneous closure of patent arterial ducts. One hundred thirty-six (93.8%) of the patients were from a geographic area of 2100-2800 m above sea level. RESULTS: Successful device closure was achieved in 143 cases. It was difficult to achieve device stability in two patients with expansile ducts. Therefore, they were treated surgically. The devices used were various types of duct occluder devices in 131 patients, while atrial and ventricular septal occluders were used in eight patients. For the group, mean systolic pulmonary artery (PA) pressure decreased from 47.0 ± 16.7 mmHg before occlusion to 29.0 ± 7.4 mmHg after occlusion (P ≤ 0.001)., mean diastolic PA pressure from 25.0 ± 10.9 mmHg to 14.8 ± 6.0 mmHg and the average mean PA pressure decreased from 35.9 ± 13.5 mmHg to 21.1 ± 6.5 mmHg. Complications (4.8%) included device and coil embolization, bleeding, and pulse loss. On follow-up (mean duration of 36.1 ± 12.1 months, range 12-62 months), 137 patients were in functional class 1, 3 had residual shunt, 2 had device migration and one patient had persisting pulse loss. CONCLUSIONS: Successful duct closure was achieved in the vast majority of patients, even though the ducts were larger and significant number of them had pulmonary hypertension in this high altitude group. There was a relatively higher incidence of residual shunts and device migration in this series, generally due to the nonavailability of optimal device and surgical support. Long-term follow-up is required before we can draw conclusions with regard to the sustainability of drop in PA pressures. Septal Occluder devices may be a possible alternative for large tubular or window-type ducts with severe pulmonary hypertension, where there may be concerns about the size and stability of duct occluder devices. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4608196/ /pubmed/26556965 http://dx.doi.org/10.4103/0974-2069.164690 Text en Copyright: © 2015 Annals of Pediatric Cardiology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Tefera, Endale
Qureshi, Shakeel A
Bermudez-Cañete, Ramòn
Rubio, Lola
Percutaneous closure of patent arterial ducts in patients from high altitude: a sub-Saharan experience
title Percutaneous closure of patent arterial ducts in patients from high altitude: a sub-Saharan experience
title_full Percutaneous closure of patent arterial ducts in patients from high altitude: a sub-Saharan experience
title_fullStr Percutaneous closure of patent arterial ducts in patients from high altitude: a sub-Saharan experience
title_full_unstemmed Percutaneous closure of patent arterial ducts in patients from high altitude: a sub-Saharan experience
title_short Percutaneous closure of patent arterial ducts in patients from high altitude: a sub-Saharan experience
title_sort percutaneous closure of patent arterial ducts in patients from high altitude: a sub-saharan experience
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4608196/
https://www.ncbi.nlm.nih.gov/pubmed/26556965
http://dx.doi.org/10.4103/0974-2069.164690
work_keys_str_mv AT teferaendale percutaneousclosureofpatentarterialductsinpatientsfromhighaltitudeasubsaharanexperience
AT qureshishakeela percutaneousclosureofpatentarterialductsinpatientsfromhighaltitudeasubsaharanexperience
AT bermudezcaneteramon percutaneousclosureofpatentarterialductsinpatientsfromhighaltitudeasubsaharanexperience
AT rubiolola percutaneousclosureofpatentarterialductsinpatientsfromhighaltitudeasubsaharanexperience