Fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement
BACKGROUND: The use of goal directed fluid protocols in intermediate risk patients undergoing hip or knee replacement was studied in few trials using invasive monitoring. For this reason we have implemented two different fluid management protocols, both based on a novel totally non-invasive arterial...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4608292/ https://www.ncbi.nlm.nih.gov/pubmed/26471495 http://dx.doi.org/10.1186/s12871-015-0131-8 |
_version_ | 1782395645810704384 |
---|---|
author | Benes, Jan Haidingerova, Lenka Pouska, Jiri Stepanik, Jan Stenglova, Alena Zatloukal, Jan Pradl, Richard Chytra, Ivan Kasal, Eduard |
author_facet | Benes, Jan Haidingerova, Lenka Pouska, Jiri Stepanik, Jan Stenglova, Alena Zatloukal, Jan Pradl, Richard Chytra, Ivan Kasal, Eduard |
author_sort | Benes, Jan |
collection | PubMed |
description | BACKGROUND: The use of goal directed fluid protocols in intermediate risk patients undergoing hip or knee replacement was studied in few trials using invasive monitoring. For this reason we have implemented two different fluid management protocols, both based on a novel totally non-invasive arterial pressure monitoring device and compared them to the standard (no-protocol) treatment applied before the transition in our academic institution. METHODS: Three treatment groups were compared in this prospective study: the observational (CONTROL, N = 40) group before adoption of fluid protocols and two randomized groups after the transition to protocol fluid management with the use of the continuous non-invasive blood pressure monitoring (CNAP®) device. In the PRESSURE group (N = 40) standard variables were used for restrictive fluid therapy. Goal directed fluid therapy using pulse pressure variation was used in the GDFT arm (N = 40). The influence on the rate of postoperative complications, on the hospital length of stay and other parameters was assessed. RESULTS: Both protocols were associated with decreased fluid administration and maintained hemodynamic stability. Reduced rate of postoperative infection and organ complications (22 (55 %) vs. 33 (83 %) patients; p = 0.016; relative risk 0.67 (0.49–0.91)) was observed in the GDFT group compared to CONTROL. Lower number of patients receiving transfusion (4 (10 %) in GDFT vs. 17 (43 %) in CONTROL; p = 0.005) might contribute to this observation. No significant differences were observed in other end-points. CONCLUSION: In our study, the use of the fluid protocol based on pulse pressure variation assessed using continuous non-invasive arterial pressure measurement seems to be associated with a reduction in postoperative complications and transfusion needs as compared to standard no-protocol treatment. TRIAL REGISTRATION: ACTRN12612001014842 ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12871-015-0131-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4608292 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-46082922015-10-17 Fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement Benes, Jan Haidingerova, Lenka Pouska, Jiri Stepanik, Jan Stenglova, Alena Zatloukal, Jan Pradl, Richard Chytra, Ivan Kasal, Eduard BMC Anesthesiol Research Article BACKGROUND: The use of goal directed fluid protocols in intermediate risk patients undergoing hip or knee replacement was studied in few trials using invasive monitoring. For this reason we have implemented two different fluid management protocols, both based on a novel totally non-invasive arterial pressure monitoring device and compared them to the standard (no-protocol) treatment applied before the transition in our academic institution. METHODS: Three treatment groups were compared in this prospective study: the observational (CONTROL, N = 40) group before adoption of fluid protocols and two randomized groups after the transition to protocol fluid management with the use of the continuous non-invasive blood pressure monitoring (CNAP®) device. In the PRESSURE group (N = 40) standard variables were used for restrictive fluid therapy. Goal directed fluid therapy using pulse pressure variation was used in the GDFT arm (N = 40). The influence on the rate of postoperative complications, on the hospital length of stay and other parameters was assessed. RESULTS: Both protocols were associated with decreased fluid administration and maintained hemodynamic stability. Reduced rate of postoperative infection and organ complications (22 (55 %) vs. 33 (83 %) patients; p = 0.016; relative risk 0.67 (0.49–0.91)) was observed in the GDFT group compared to CONTROL. Lower number of patients receiving transfusion (4 (10 %) in GDFT vs. 17 (43 %) in CONTROL; p = 0.005) might contribute to this observation. No significant differences were observed in other end-points. CONCLUSION: In our study, the use of the fluid protocol based on pulse pressure variation assessed using continuous non-invasive arterial pressure measurement seems to be associated with a reduction in postoperative complications and transfusion needs as compared to standard no-protocol treatment. TRIAL REGISTRATION: ACTRN12612001014842 ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12871-015-0131-8) contains supplementary material, which is available to authorized users. BioMed Central 2015-10-15 /pmc/articles/PMC4608292/ /pubmed/26471495 http://dx.doi.org/10.1186/s12871-015-0131-8 Text en © Benes et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Benes, Jan Haidingerova, Lenka Pouska, Jiri Stepanik, Jan Stenglova, Alena Zatloukal, Jan Pradl, Richard Chytra, Ivan Kasal, Eduard Fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement |
title | Fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement |
title_full | Fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement |
title_fullStr | Fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement |
title_full_unstemmed | Fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement |
title_short | Fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement |
title_sort | fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4608292/ https://www.ncbi.nlm.nih.gov/pubmed/26471495 http://dx.doi.org/10.1186/s12871-015-0131-8 |
work_keys_str_mv | AT benesjan fluidmanagementguidedbyacontinuousnoninvasivearterialpressuredeviceisassociatedwithdecreasedpostoperativemorbidityaftertotalkneeandhipreplacement AT haidingerovalenka fluidmanagementguidedbyacontinuousnoninvasivearterialpressuredeviceisassociatedwithdecreasedpostoperativemorbidityaftertotalkneeandhipreplacement AT pouskajiri fluidmanagementguidedbyacontinuousnoninvasivearterialpressuredeviceisassociatedwithdecreasedpostoperativemorbidityaftertotalkneeandhipreplacement AT stepanikjan fluidmanagementguidedbyacontinuousnoninvasivearterialpressuredeviceisassociatedwithdecreasedpostoperativemorbidityaftertotalkneeandhipreplacement AT stenglovaalena fluidmanagementguidedbyacontinuousnoninvasivearterialpressuredeviceisassociatedwithdecreasedpostoperativemorbidityaftertotalkneeandhipreplacement AT zatloukaljan fluidmanagementguidedbyacontinuousnoninvasivearterialpressuredeviceisassociatedwithdecreasedpostoperativemorbidityaftertotalkneeandhipreplacement AT pradlrichard fluidmanagementguidedbyacontinuousnoninvasivearterialpressuredeviceisassociatedwithdecreasedpostoperativemorbidityaftertotalkneeandhipreplacement AT chytraivan fluidmanagementguidedbyacontinuousnoninvasivearterialpressuredeviceisassociatedwithdecreasedpostoperativemorbidityaftertotalkneeandhipreplacement AT kasaleduard fluidmanagementguidedbyacontinuousnoninvasivearterialpressuredeviceisassociatedwithdecreasedpostoperativemorbidityaftertotalkneeandhipreplacement |