Cargando…

Diagnostic Accuracy of Chest x-Ray and Ultrasonography in Detection of Community Acquired Pneumonia; a Brief Report

INTRODUCTION: Chest x-ray (CXR) is the simplest diagnostic tool of Community Acquired Pneumonia (CAP), but it has some limitation. Therefore, the aim of this study is comparing the diagnostic accuracy of CXR and chest ultrasonography (CUS) in detection of CAP. METHODS: In the present study, a consec...

Descripción completa

Detalles Bibliográficos
Autores principales: Taghizadieh, Ali, Ala, Alireza, Rahmani, Farzad, Nadi, Akbar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shahid Beheshti University of Medical Sciences 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4608340/
https://www.ncbi.nlm.nih.gov/pubmed/26495396
_version_ 1782395657058779136
author Taghizadieh, Ali
Ala, Alireza
Rahmani, Farzad
Nadi, Akbar
author_facet Taghizadieh, Ali
Ala, Alireza
Rahmani, Farzad
Nadi, Akbar
author_sort Taghizadieh, Ali
collection PubMed
description INTRODUCTION: Chest x-ray (CXR) is the simplest diagnostic tool of Community Acquired Pneumonia (CAP), but it has some limitation. Therefore, the aim of this study is comparing the diagnostic accuracy of CXR and chest ultrasonography (CUS) in detection of CAP. METHODS: In the present study, a consecutive sample of suspected patients with CAP was underwent CUS, CXR, and chest computed tomography (CT) scan. Diagnostic accuracy of CUS and CXR was assessed by calculating the sensitivity, specificity, predictive values, and likelihood ratios using SPSS 20 statistical software. RESULTS: 30 patients with CAP were enrolled (93.3% male with mean age of 63.8 ± 18.3 years). Sensitivity of CUS and CXR in detection of CAP were 100.0% (95% Cl: 85.4-100.0) and 93.1% (95% Cl: 75.8-98.8), respectively. Specificity of CXR was 0.0 (95% Cl: 0.0-94.5), while the CUS specificity was not calculable. CONCLUSION: Findings of the present study demonstrated on the higher diagnostic accuracy of CUS versus CXR in detection of pneumonia.
format Online
Article
Text
id pubmed-4608340
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Shahid Beheshti University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-46083402015-10-22 Diagnostic Accuracy of Chest x-Ray and Ultrasonography in Detection of Community Acquired Pneumonia; a Brief Report Taghizadieh, Ali Ala, Alireza Rahmani, Farzad Nadi, Akbar Emerg (Tehran) Brief Report INTRODUCTION: Chest x-ray (CXR) is the simplest diagnostic tool of Community Acquired Pneumonia (CAP), but it has some limitation. Therefore, the aim of this study is comparing the diagnostic accuracy of CXR and chest ultrasonography (CUS) in detection of CAP. METHODS: In the present study, a consecutive sample of suspected patients with CAP was underwent CUS, CXR, and chest computed tomography (CT) scan. Diagnostic accuracy of CUS and CXR was assessed by calculating the sensitivity, specificity, predictive values, and likelihood ratios using SPSS 20 statistical software. RESULTS: 30 patients with CAP were enrolled (93.3% male with mean age of 63.8 ± 18.3 years). Sensitivity of CUS and CXR in detection of CAP were 100.0% (95% Cl: 85.4-100.0) and 93.1% (95% Cl: 75.8-98.8), respectively. Specificity of CXR was 0.0 (95% Cl: 0.0-94.5), while the CUS specificity was not calculable. CONCLUSION: Findings of the present study demonstrated on the higher diagnostic accuracy of CUS versus CXR in detection of pneumonia. Shahid Beheshti University of Medical Sciences 2015 /pmc/articles/PMC4608340/ /pubmed/26495396 Text en Copyright © 2015 Shahid Beheshti University of Medical Sciences. This open-access article distributed under the terms of the Creative Commons Attribution Noncommercial 3.0 License (CC BY-NC 3.0)., (https://creativecommons.org/licenses/by-nc/3.0/).
spellingShingle Brief Report
Taghizadieh, Ali
Ala, Alireza
Rahmani, Farzad
Nadi, Akbar
Diagnostic Accuracy of Chest x-Ray and Ultrasonography in Detection of Community Acquired Pneumonia; a Brief Report
title Diagnostic Accuracy of Chest x-Ray and Ultrasonography in Detection of Community Acquired Pneumonia; a Brief Report
title_full Diagnostic Accuracy of Chest x-Ray and Ultrasonography in Detection of Community Acquired Pneumonia; a Brief Report
title_fullStr Diagnostic Accuracy of Chest x-Ray and Ultrasonography in Detection of Community Acquired Pneumonia; a Brief Report
title_full_unstemmed Diagnostic Accuracy of Chest x-Ray and Ultrasonography in Detection of Community Acquired Pneumonia; a Brief Report
title_short Diagnostic Accuracy of Chest x-Ray and Ultrasonography in Detection of Community Acquired Pneumonia; a Brief Report
title_sort diagnostic accuracy of chest x-ray and ultrasonography in detection of community acquired pneumonia; a brief report
topic Brief Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4608340/
https://www.ncbi.nlm.nih.gov/pubmed/26495396
work_keys_str_mv AT taghizadiehali diagnosticaccuracyofchestxrayandultrasonographyindetectionofcommunityacquiredpneumoniaabriefreport
AT alaalireza diagnosticaccuracyofchestxrayandultrasonographyindetectionofcommunityacquiredpneumoniaabriefreport
AT rahmanifarzad diagnosticaccuracyofchestxrayandultrasonographyindetectionofcommunityacquiredpneumoniaabriefreport
AT nadiakbar diagnosticaccuracyofchestxrayandultrasonographyindetectionofcommunityacquiredpneumoniaabriefreport