Cargando…

An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes

Automated closed-loop insulin infusion therapy has been studied for many years. In closed-loop system, the control algorithm is the key technique of precise insulin infusion. The control algorithm needs to be designed and validated. In this paper, an improved PID algorithm based on insulin-on-board...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Ruiqiang, Li, Chengwei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4609789/
https://www.ncbi.nlm.nih.gov/pubmed/26550021
http://dx.doi.org/10.1155/2015/281589
_version_ 1782395846960087040
author Hu, Ruiqiang
Li, Chengwei
author_facet Hu, Ruiqiang
Li, Chengwei
author_sort Hu, Ruiqiang
collection PubMed
description Automated closed-loop insulin infusion therapy has been studied for many years. In closed-loop system, the control algorithm is the key technique of precise insulin infusion. The control algorithm needs to be designed and validated. In this paper, an improved PID algorithm based on insulin-on-board estimate is proposed and computer simulations are done using a combinational mathematical model of the dynamics of blood glucose-insulin regulation in the blood system. The simulation results demonstrate that the improved PID algorithm can perform well in different carbohydrate ingestion and different insulin sensitivity situations. Compared with the traditional PID algorithm, the control performance is improved obviously and hypoglycemia can be avoided. To verify the effectiveness of the proposed control algorithm, in silico testing is done using the UVa/Padova virtual patient software.
format Online
Article
Text
id pubmed-4609789
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-46097892015-11-08 An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes Hu, Ruiqiang Li, Chengwei Comput Math Methods Med Research Article Automated closed-loop insulin infusion therapy has been studied for many years. In closed-loop system, the control algorithm is the key technique of precise insulin infusion. The control algorithm needs to be designed and validated. In this paper, an improved PID algorithm based on insulin-on-board estimate is proposed and computer simulations are done using a combinational mathematical model of the dynamics of blood glucose-insulin regulation in the blood system. The simulation results demonstrate that the improved PID algorithm can perform well in different carbohydrate ingestion and different insulin sensitivity situations. Compared with the traditional PID algorithm, the control performance is improved obviously and hypoglycemia can be avoided. To verify the effectiveness of the proposed control algorithm, in silico testing is done using the UVa/Padova virtual patient software. Hindawi Publishing Corporation 2015 2015-10-05 /pmc/articles/PMC4609789/ /pubmed/26550021 http://dx.doi.org/10.1155/2015/281589 Text en Copyright © 2015 R. Hu and C. Li. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hu, Ruiqiang
Li, Chengwei
An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes
title An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes
title_full An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes
title_fullStr An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes
title_full_unstemmed An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes
title_short An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes
title_sort improved pid algorithm based on insulin-on-board estimate for blood glucose control with type 1 diabetes
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4609789/
https://www.ncbi.nlm.nih.gov/pubmed/26550021
http://dx.doi.org/10.1155/2015/281589
work_keys_str_mv AT huruiqiang animprovedpidalgorithmbasedoninsulinonboardestimateforbloodglucosecontrolwithtype1diabetes
AT lichengwei animprovedpidalgorithmbasedoninsulinonboardestimateforbloodglucosecontrolwithtype1diabetes
AT huruiqiang improvedpidalgorithmbasedoninsulinonboardestimateforbloodglucosecontrolwithtype1diabetes
AT lichengwei improvedpidalgorithmbasedoninsulinonboardestimateforbloodglucosecontrolwithtype1diabetes