Cargando…

Mach-Zehnder Interferometer Biochemical Sensor Based on Silicon-on-Insulator Rib Waveguide with Large Cross Section

A high-sensitivity Mach-Zehnder interferometer (MZI) biochemical sensing platform based on Silicon-in-insulator (SOI) rib waveguide with large cross section is proposed in this paper. Based on the analyses of the evanescent field intensity, the mode polarization and cross section dimensions of the S...

Descripción completa

Detalles Bibliográficos
Autores principales: Yuan, Dengpeng, Dong, Ying, Liu, Yujin, Li, Tianjian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4610462/
https://www.ncbi.nlm.nih.gov/pubmed/26343678
http://dx.doi.org/10.3390/s150921500
_version_ 1782395942547226624
author Yuan, Dengpeng
Dong, Ying
Liu, Yujin
Li, Tianjian
author_facet Yuan, Dengpeng
Dong, Ying
Liu, Yujin
Li, Tianjian
author_sort Yuan, Dengpeng
collection PubMed
description A high-sensitivity Mach-Zehnder interferometer (MZI) biochemical sensing platform based on Silicon-in-insulator (SOI) rib waveguide with large cross section is proposed in this paper. Based on the analyses of the evanescent field intensity, the mode polarization and cross section dimensions of the SOI rib waveguide are optimized through finite difference method (FDM) simulation. To realize high-resolution MZI read-out configuration based on the SOI rib waveguide, medium-filled trenches are employed and their performances are simulated through two-dimensional finite-difference-time domain (2D-FDTD) method. With the fundamental EH-polarized mode of the SOI rib waveguide with a total rib height of 10 μm, an outside rib height of 5 μm and a rib width of 2.5 μm at the operating wavelength of 1550 nm, when the length of the sensitive window in the MZI configuration is 10 mm, a homogeneous sensitivity of 7296.6%/refractive index unit (RIU) is obtained. Supposing the resolutions of the photoelectric detectors connected to the output ports are 0.2%, the MZI sensor can achieve a detection limit of 2.74 × 10(−6) RIU. Due to high coupling efficiency of SOI rib waveguide with large cross section with standard single-mode glass optical fiber, the proposed MZI sensing platform can be conveniently integrated with optical fiber communication systems and (opto-) electronic systems, and therefore has the potential to realize remote sensing, in situ real-time detecting, and possible applications in the internet of things.
format Online
Article
Text
id pubmed-4610462
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-46104622015-10-26 Mach-Zehnder Interferometer Biochemical Sensor Based on Silicon-on-Insulator Rib Waveguide with Large Cross Section Yuan, Dengpeng Dong, Ying Liu, Yujin Li, Tianjian Sensors (Basel) Article A high-sensitivity Mach-Zehnder interferometer (MZI) biochemical sensing platform based on Silicon-in-insulator (SOI) rib waveguide with large cross section is proposed in this paper. Based on the analyses of the evanescent field intensity, the mode polarization and cross section dimensions of the SOI rib waveguide are optimized through finite difference method (FDM) simulation. To realize high-resolution MZI read-out configuration based on the SOI rib waveguide, medium-filled trenches are employed and their performances are simulated through two-dimensional finite-difference-time domain (2D-FDTD) method. With the fundamental EH-polarized mode of the SOI rib waveguide with a total rib height of 10 μm, an outside rib height of 5 μm and a rib width of 2.5 μm at the operating wavelength of 1550 nm, when the length of the sensitive window in the MZI configuration is 10 mm, a homogeneous sensitivity of 7296.6%/refractive index unit (RIU) is obtained. Supposing the resolutions of the photoelectric detectors connected to the output ports are 0.2%, the MZI sensor can achieve a detection limit of 2.74 × 10(−6) RIU. Due to high coupling efficiency of SOI rib waveguide with large cross section with standard single-mode glass optical fiber, the proposed MZI sensing platform can be conveniently integrated with optical fiber communication systems and (opto-) electronic systems, and therefore has the potential to realize remote sensing, in situ real-time detecting, and possible applications in the internet of things. MDPI 2015-08-28 /pmc/articles/PMC4610462/ /pubmed/26343678 http://dx.doi.org/10.3390/s150921500 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yuan, Dengpeng
Dong, Ying
Liu, Yujin
Li, Tianjian
Mach-Zehnder Interferometer Biochemical Sensor Based on Silicon-on-Insulator Rib Waveguide with Large Cross Section
title Mach-Zehnder Interferometer Biochemical Sensor Based on Silicon-on-Insulator Rib Waveguide with Large Cross Section
title_full Mach-Zehnder Interferometer Biochemical Sensor Based on Silicon-on-Insulator Rib Waveguide with Large Cross Section
title_fullStr Mach-Zehnder Interferometer Biochemical Sensor Based on Silicon-on-Insulator Rib Waveguide with Large Cross Section
title_full_unstemmed Mach-Zehnder Interferometer Biochemical Sensor Based on Silicon-on-Insulator Rib Waveguide with Large Cross Section
title_short Mach-Zehnder Interferometer Biochemical Sensor Based on Silicon-on-Insulator Rib Waveguide with Large Cross Section
title_sort mach-zehnder interferometer biochemical sensor based on silicon-on-insulator rib waveguide with large cross section
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4610462/
https://www.ncbi.nlm.nih.gov/pubmed/26343678
http://dx.doi.org/10.3390/s150921500
work_keys_str_mv AT yuandengpeng machzehnderinterferometerbiochemicalsensorbasedonsilicononinsulatorribwaveguidewithlargecrosssection
AT dongying machzehnderinterferometerbiochemicalsensorbasedonsilicononinsulatorribwaveguidewithlargecrosssection
AT liuyujin machzehnderinterferometerbiochemicalsensorbasedonsilicononinsulatorribwaveguidewithlargecrosssection
AT litianjian machzehnderinterferometerbiochemicalsensorbasedonsilicononinsulatorribwaveguidewithlargecrosssection