Cargando…
Improving the Detection Limit in a Capillary Raman System for In Situ Gas Analysis by Means of Fluorescence Reduction
Raman spectroscopy for low-pressure or trace gas analysis is rather challenging, in particular in process control applications requiring trace detection and real-time response; in general, enhancement techniques are required. One possible enhancement approach which enjoys increasing popularity makes...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4610545/ https://www.ncbi.nlm.nih.gov/pubmed/26378545 http://dx.doi.org/10.3390/s150923110 |
_version_ | 1782395961243336704 |
---|---|
author | Rupp, Simone Off, Andreas Seitz-Moskaliuk, Hendrik James, Timothy M. Telle, Helmut H. |
author_facet | Rupp, Simone Off, Andreas Seitz-Moskaliuk, Hendrik James, Timothy M. Telle, Helmut H. |
author_sort | Rupp, Simone |
collection | PubMed |
description | Raman spectroscopy for low-pressure or trace gas analysis is rather challenging, in particular in process control applications requiring trace detection and real-time response; in general, enhancement techniques are required. One possible enhancement approach which enjoys increasing popularity makes use of an internally-reflective capillary as the gas cell. However, in the majority of cases, such capillary systems were often limited in their achievable sensitivity by a significant fluorescence background, which is generated as a consequence of interactions between the laser light and optical glass components in the setup. In order to understand and counteract these problems we have investigated a range of fluorescence-reducing measures, including the rearrangement of optical elements, and the replacement of glass components—including the capillary itself—by metal alternatives. These studies now have led to a capillary setup in which fluorescence is practically eliminated and substantial signal enhancement over standard Raman setups is achieved. With this improved (prototype) setup, detection limits of well below 1 mbar could be obtained in sub-second acquisition times, demonstrating the potential of capillary Raman spectroscopy for real-time, in situ gas sensing and process control applications, down to trace level concentrations. |
format | Online Article Text |
id | pubmed-4610545 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-46105452015-10-26 Improving the Detection Limit in a Capillary Raman System for In Situ Gas Analysis by Means of Fluorescence Reduction Rupp, Simone Off, Andreas Seitz-Moskaliuk, Hendrik James, Timothy M. Telle, Helmut H. Sensors (Basel) Article Raman spectroscopy for low-pressure or trace gas analysis is rather challenging, in particular in process control applications requiring trace detection and real-time response; in general, enhancement techniques are required. One possible enhancement approach which enjoys increasing popularity makes use of an internally-reflective capillary as the gas cell. However, in the majority of cases, such capillary systems were often limited in their achievable sensitivity by a significant fluorescence background, which is generated as a consequence of interactions between the laser light and optical glass components in the setup. In order to understand and counteract these problems we have investigated a range of fluorescence-reducing measures, including the rearrangement of optical elements, and the replacement of glass components—including the capillary itself—by metal alternatives. These studies now have led to a capillary setup in which fluorescence is practically eliminated and substantial signal enhancement over standard Raman setups is achieved. With this improved (prototype) setup, detection limits of well below 1 mbar could be obtained in sub-second acquisition times, demonstrating the potential of capillary Raman spectroscopy for real-time, in situ gas sensing and process control applications, down to trace level concentrations. MDPI 2015-09-11 /pmc/articles/PMC4610545/ /pubmed/26378545 http://dx.doi.org/10.3390/s150923110 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rupp, Simone Off, Andreas Seitz-Moskaliuk, Hendrik James, Timothy M. Telle, Helmut H. Improving the Detection Limit in a Capillary Raman System for In Situ Gas Analysis by Means of Fluorescence Reduction |
title | Improving the Detection Limit in a Capillary Raman System for In Situ Gas Analysis by Means of Fluorescence Reduction |
title_full | Improving the Detection Limit in a Capillary Raman System for In Situ Gas Analysis by Means of Fluorescence Reduction |
title_fullStr | Improving the Detection Limit in a Capillary Raman System for In Situ Gas Analysis by Means of Fluorescence Reduction |
title_full_unstemmed | Improving the Detection Limit in a Capillary Raman System for In Situ Gas Analysis by Means of Fluorescence Reduction |
title_short | Improving the Detection Limit in a Capillary Raman System for In Situ Gas Analysis by Means of Fluorescence Reduction |
title_sort | improving the detection limit in a capillary raman system for in situ gas analysis by means of fluorescence reduction |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4610545/ https://www.ncbi.nlm.nih.gov/pubmed/26378545 http://dx.doi.org/10.3390/s150923110 |
work_keys_str_mv | AT ruppsimone improvingthedetectionlimitinacapillaryramansystemforinsitugasanalysisbymeansoffluorescencereduction AT offandreas improvingthedetectionlimitinacapillaryramansystemforinsitugasanalysisbymeansoffluorescencereduction AT seitzmoskaliukhendrik improvingthedetectionlimitinacapillaryramansystemforinsitugasanalysisbymeansoffluorescencereduction AT jamestimothym improvingthedetectionlimitinacapillaryramansystemforinsitugasanalysisbymeansoffluorescencereduction AT tellehelmuth improvingthedetectionlimitinacapillaryramansystemforinsitugasanalysisbymeansoffluorescencereduction |