Cargando…

Investigation of postoperative intraocular pressure in cases of silicone oil removal using 25-gauge transconjunctival sutureless vitrectomy with oblique incisions

BACKGROUND: The purpose of this study was to investigate postoperative intraocular pressure (IOP) in cases of silicone oil (SO) removal when using 25-gauge transconjunctival sutureless vitrectomy (TSV) with oblique incisions. METHODS: We enrolled ten consecutive eyes with SO removal (SO group) and e...

Descripción completa

Detalles Bibliográficos
Autores principales: Takashina, Hirotsugu, Watanabe, Akira, Tsuneoka, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4610883/
https://www.ncbi.nlm.nih.gov/pubmed/26508831
http://dx.doi.org/10.2147/OPTH.S93376
Descripción
Sumario:BACKGROUND: The purpose of this study was to investigate postoperative intraocular pressure (IOP) in cases of silicone oil (SO) removal when using 25-gauge transconjunctival sutureless vitrectomy (TSV) with oblique incisions. METHODS: We enrolled ten consecutive eyes with SO removal (SO group) and eleven consecutive eyes with idiopathic epiretinal membrane (ERM) as the initial vitrectomy (ERM group) in cases using 25-gauge TSV with oblique incisions. Postoperative IOPs were compared between the two groups at each of the four examination periods. RESULTS: No significant differences were identified in any of the periods examined. CONCLUSION: The use of 25-gauge TSV with oblique incisions resulted in almost equivalent postoperative IOPs between cases with SO removal and idiopathic ERM as the initial operation. Self-sealing sclerotomy in 25-gauge TSV with oblique incisions may primarily involve the valve architecture, and be complemented by vitreous incarceration.