Cargando…

The sulcus line of the trochlear groove is more accurate than Whiteside’s Line in determining femoral component rotation

PURPOSE: The sulcus line (SL) is a three-dimensional curve produced from multiple points along the trochlear groove. Whiteside’s Line, also known as the anteroposterior axis (APA), is derived from single anterior and posterior points. The purposes of the two studies presented in this paper are to (1...

Descripción completa

Detalles Bibliográficos
Autores principales: Talbot, Simon, Dimitriou, Pandelis, Radic, Ross, Zordan, Rachel, Bartlett, John
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4611010/
https://www.ncbi.nlm.nih.gov/pubmed/24981989
http://dx.doi.org/10.1007/s00167-014-3137-8
_version_ 1782396031924699136
author Talbot, Simon
Dimitriou, Pandelis
Radic, Ross
Zordan, Rachel
Bartlett, John
author_facet Talbot, Simon
Dimitriou, Pandelis
Radic, Ross
Zordan, Rachel
Bartlett, John
author_sort Talbot, Simon
collection PubMed
description PURPOSE: The sulcus line (SL) is a three-dimensional curve produced from multiple points along the trochlear groove. Whiteside’s Line, also known as the anteroposterior axis (APA), is derived from single anterior and posterior points. The purposes of the two studies presented in this paper are to (1) assess the results from the clinical use of the SL in a large clinical series, (2) measure the SL and the APA on three-dimensional CT reconstructions, (3) demonstrate the effect of parallax error on the use of the APA and (4) determine the accuracy of an axis derived by combining the SL and the posterior condylar axis (PCA). METHODS: In the first study, we assessed the SL using a large, single surgeon series of consecutive patients undergoing primary total knee arthroplasties. The post-operative CT scans of patients (n = 200) were examined to determine the final rotational alignment of the femoral component. In the second study, measurements were taken in a series of 3DCT reconstructions of osteoarthritic knees (n = 44). RESULTS: The mean position of the femoral component in the clinical series was 0.6° externally rotated to the surgical epicondylar axis, with a standard deviation of 2.9° (ranges from −7.2° to 6.7°). On the 3DCT reconstructions, the APA (88.2° ± 4.2°) had significantly higher variance than the SL (90.3° ± 2.7°) (F = 5.82 and p = 0.017). An axis derived by averaging the SL and the PCA+3° produced a significant decrease in both the number of outliers (p = 0.03 vs. PCA and p = 0.007 vs. SL) and the variance (F = 6.15 and p = 0.015 vs. SL). The coronal alignment of the SL varied widely relative to the mechanical axis (0.4° ± 3.8°) and the distal condylar surface (2.6° ± 4.3°). CONCLUSIONS: The multiple points used to determine the SL confer anatomical and geometrical advantages, and therefore, it should be considered a separate rotational landmark to the APA. These findings may explain the high degree of variability in the measurement of the APA which is documented in the literature. Combining a geometrically correct SL and the PCA is likely to further improve accuracy.
format Online
Article
Text
id pubmed-4611010
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-46110102015-10-22 The sulcus line of the trochlear groove is more accurate than Whiteside’s Line in determining femoral component rotation Talbot, Simon Dimitriou, Pandelis Radic, Ross Zordan, Rachel Bartlett, John Knee Surg Sports Traumatol Arthrosc Knee PURPOSE: The sulcus line (SL) is a three-dimensional curve produced from multiple points along the trochlear groove. Whiteside’s Line, also known as the anteroposterior axis (APA), is derived from single anterior and posterior points. The purposes of the two studies presented in this paper are to (1) assess the results from the clinical use of the SL in a large clinical series, (2) measure the SL and the APA on three-dimensional CT reconstructions, (3) demonstrate the effect of parallax error on the use of the APA and (4) determine the accuracy of an axis derived by combining the SL and the posterior condylar axis (PCA). METHODS: In the first study, we assessed the SL using a large, single surgeon series of consecutive patients undergoing primary total knee arthroplasties. The post-operative CT scans of patients (n = 200) were examined to determine the final rotational alignment of the femoral component. In the second study, measurements were taken in a series of 3DCT reconstructions of osteoarthritic knees (n = 44). RESULTS: The mean position of the femoral component in the clinical series was 0.6° externally rotated to the surgical epicondylar axis, with a standard deviation of 2.9° (ranges from −7.2° to 6.7°). On the 3DCT reconstructions, the APA (88.2° ± 4.2°) had significantly higher variance than the SL (90.3° ± 2.7°) (F = 5.82 and p = 0.017). An axis derived by averaging the SL and the PCA+3° produced a significant decrease in both the number of outliers (p = 0.03 vs. PCA and p = 0.007 vs. SL) and the variance (F = 6.15 and p = 0.015 vs. SL). The coronal alignment of the SL varied widely relative to the mechanical axis (0.4° ± 3.8°) and the distal condylar surface (2.6° ± 4.3°). CONCLUSIONS: The multiple points used to determine the SL confer anatomical and geometrical advantages, and therefore, it should be considered a separate rotational landmark to the APA. These findings may explain the high degree of variability in the measurement of the APA which is documented in the literature. Combining a geometrically correct SL and the PCA is likely to further improve accuracy. Springer Berlin Heidelberg 2014-07-01 2015 /pmc/articles/PMC4611010/ /pubmed/24981989 http://dx.doi.org/10.1007/s00167-014-3137-8 Text en © Springer-Verlag Berlin Heidelberg 2014
spellingShingle Knee
Talbot, Simon
Dimitriou, Pandelis
Radic, Ross
Zordan, Rachel
Bartlett, John
The sulcus line of the trochlear groove is more accurate than Whiteside’s Line in determining femoral component rotation
title The sulcus line of the trochlear groove is more accurate than Whiteside’s Line in determining femoral component rotation
title_full The sulcus line of the trochlear groove is more accurate than Whiteside’s Line in determining femoral component rotation
title_fullStr The sulcus line of the trochlear groove is more accurate than Whiteside’s Line in determining femoral component rotation
title_full_unstemmed The sulcus line of the trochlear groove is more accurate than Whiteside’s Line in determining femoral component rotation
title_short The sulcus line of the trochlear groove is more accurate than Whiteside’s Line in determining femoral component rotation
title_sort sulcus line of the trochlear groove is more accurate than whiteside’s line in determining femoral component rotation
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4611010/
https://www.ncbi.nlm.nih.gov/pubmed/24981989
http://dx.doi.org/10.1007/s00167-014-3137-8
work_keys_str_mv AT talbotsimon thesulcuslineofthetrochleargrooveismoreaccuratethanwhitesideslineindeterminingfemoralcomponentrotation
AT dimitrioupandelis thesulcuslineofthetrochleargrooveismoreaccuratethanwhitesideslineindeterminingfemoralcomponentrotation
AT radicross thesulcuslineofthetrochleargrooveismoreaccuratethanwhitesideslineindeterminingfemoralcomponentrotation
AT zordanrachel thesulcuslineofthetrochleargrooveismoreaccuratethanwhitesideslineindeterminingfemoralcomponentrotation
AT bartlettjohn thesulcuslineofthetrochleargrooveismoreaccuratethanwhitesideslineindeterminingfemoralcomponentrotation
AT talbotsimon sulcuslineofthetrochleargrooveismoreaccuratethanwhitesideslineindeterminingfemoralcomponentrotation
AT dimitrioupandelis sulcuslineofthetrochleargrooveismoreaccuratethanwhitesideslineindeterminingfemoralcomponentrotation
AT radicross sulcuslineofthetrochleargrooveismoreaccuratethanwhitesideslineindeterminingfemoralcomponentrotation
AT zordanrachel sulcuslineofthetrochleargrooveismoreaccuratethanwhitesideslineindeterminingfemoralcomponentrotation
AT bartlettjohn sulcuslineofthetrochleargrooveismoreaccuratethanwhitesideslineindeterminingfemoralcomponentrotation