Cargando…

Quality Assurance System Using Statistical Process Control: An Implementation for Image Cytometry

Aims: Optical technologies have shown some promise for improving the care of cervical neoplasia. We are currently evaluating fluorescence and reflectance spectroscopy and quantitative cyto‐histopathology for cervical neoplasia screening and diagnosis. Here we describe the establishment and applicati...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiu, David, Guillaud, Martial, Cox, Dennis, Follen, Michele, MacAulay, Calum
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IOS Press 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4611122/
https://www.ncbi.nlm.nih.gov/pubmed/15371646
http://dx.doi.org/10.1155/2004/794021
_version_ 1782396057267732480
author Chiu, David
Guillaud, Martial
Cox, Dennis
Follen, Michele
MacAulay, Calum
author_facet Chiu, David
Guillaud, Martial
Cox, Dennis
Follen, Michele
MacAulay, Calum
author_sort Chiu, David
collection PubMed
description Aims: Optical technologies have shown some promise for improving the care of cervical neoplasia. We are currently evaluating fluorescence and reflectance spectroscopy and quantitative cyto‐histopathology for cervical neoplasia screening and diagnosis. Here we describe the establishment and application of a quality assurance (QA) system for detecting system malfunctions and assessing the comparability of four image cytometers used in a multicenter clinical trial. Methods: Our QA system involves three levels of evaluation based on the periodicity and complexity of the measurements. We implemented our QA system at three image cytometers at the British Columbia Cancer Agency and one at M.D. Anderson Cancer Center. The measurements or tasks were performed daily, monthly, and semi‐annually. The current and voltage of the lamp, the calibration image characteristics, and the room temperature were checked daily. Long‐term stability over time, short‐term variability over time, and spatial response field uniformity were evaluated monthly. Camera linearity was measured semi‐annually. Control charts based on statistical process control techniques were used to detect when the system did not perform optimally. Results: Daily measurements have shown good consistency in room temperature, lamp and calibration behaviour. Monthly measurements have shown small coefficients of variation between and within the four devices. There have been greater differences between sessions than within sessions. Comparability among the four systems is reasonably good. Semi‐annual measurements have shown stable camera linearity. QA events were detected using the QA system. Multiple examples of event detection leading to correction of system malfunction are described in this report. Conclusions: QA programs are critical for ensuring data integrity and therefore for the conduct of multicenter clinical trials.
format Online
Article
Text
id pubmed-4611122
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher IOS Press
record_format MEDLINE/PubMed
spelling pubmed-46111222016-01-12 Quality Assurance System Using Statistical Process Control: An Implementation for Image Cytometry Chiu, David Guillaud, Martial Cox, Dennis Follen, Michele MacAulay, Calum Cell Oncol Other Aims: Optical technologies have shown some promise for improving the care of cervical neoplasia. We are currently evaluating fluorescence and reflectance spectroscopy and quantitative cyto‐histopathology for cervical neoplasia screening and diagnosis. Here we describe the establishment and application of a quality assurance (QA) system for detecting system malfunctions and assessing the comparability of four image cytometers used in a multicenter clinical trial. Methods: Our QA system involves three levels of evaluation based on the periodicity and complexity of the measurements. We implemented our QA system at three image cytometers at the British Columbia Cancer Agency and one at M.D. Anderson Cancer Center. The measurements or tasks were performed daily, monthly, and semi‐annually. The current and voltage of the lamp, the calibration image characteristics, and the room temperature were checked daily. Long‐term stability over time, short‐term variability over time, and spatial response field uniformity were evaluated monthly. Camera linearity was measured semi‐annually. Control charts based on statistical process control techniques were used to detect when the system did not perform optimally. Results: Daily measurements have shown good consistency in room temperature, lamp and calibration behaviour. Monthly measurements have shown small coefficients of variation between and within the four devices. There have been greater differences between sessions than within sessions. Comparability among the four systems is reasonably good. Semi‐annual measurements have shown stable camera linearity. QA events were detected using the QA system. Multiple examples of event detection leading to correction of system malfunction are described in this report. Conclusions: QA programs are critical for ensuring data integrity and therefore for the conduct of multicenter clinical trials. IOS Press 2004 2004-07-26 /pmc/articles/PMC4611122/ /pubmed/15371646 http://dx.doi.org/10.1155/2004/794021 Text en Copyright © 2004 Hindawi Publishing Corporation and the authors.
spellingShingle Other
Chiu, David
Guillaud, Martial
Cox, Dennis
Follen, Michele
MacAulay, Calum
Quality Assurance System Using Statistical Process Control: An Implementation for Image Cytometry
title Quality Assurance System Using Statistical Process Control: An Implementation for Image Cytometry
title_full Quality Assurance System Using Statistical Process Control: An Implementation for Image Cytometry
title_fullStr Quality Assurance System Using Statistical Process Control: An Implementation for Image Cytometry
title_full_unstemmed Quality Assurance System Using Statistical Process Control: An Implementation for Image Cytometry
title_short Quality Assurance System Using Statistical Process Control: An Implementation for Image Cytometry
title_sort quality assurance system using statistical process control: an implementation for image cytometry
topic Other
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4611122/
https://www.ncbi.nlm.nih.gov/pubmed/15371646
http://dx.doi.org/10.1155/2004/794021
work_keys_str_mv AT chiudavid qualityassurancesystemusingstatisticalprocesscontrolanimplementationforimagecytometry
AT guillaudmartial qualityassurancesystemusingstatisticalprocesscontrolanimplementationforimagecytometry
AT coxdennis qualityassurancesystemusingstatisticalprocesscontrolanimplementationforimagecytometry
AT follenmichele qualityassurancesystemusingstatisticalprocesscontrolanimplementationforimagecytometry
AT macaulaycalum qualityassurancesystemusingstatisticalprocesscontrolanimplementationforimagecytometry