Cargando…

Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study

Background and study aims: The optimal core biopsy needle for endoscopic ultrasound (EUS) is unknown. The principle aim of this study is to compare outcomes of EUS-fine-needle biopsy (EUS-FNB) with a new 19-gauge EUS histology needle (ProCore, Cook Medical Inc., Winston-Salem, North Carolina, United...

Descripción completa

Detalles Bibliográficos
Autores principales: DeWitt, John, Cho, Chang-Min, Lin, Jingmei, Al-Haddad, Mohammad, Canto, Marcia Irene, Salamone, Ashley, Hruban, Ralph H., Messallam, Ahmed A., Khashab, Mouen A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: © Georg Thieme Verlag KG 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4612231/
https://www.ncbi.nlm.nih.gov/pubmed/26528504
http://dx.doi.org/10.1055/s-0034-1392222
_version_ 1782396142731919360
author DeWitt, John
Cho, Chang-Min
Lin, Jingmei
Al-Haddad, Mohammad
Canto, Marcia Irene
Salamone, Ashley
Hruban, Ralph H.
Messallam, Ahmed A.
Khashab, Mouen A.
author_facet DeWitt, John
Cho, Chang-Min
Lin, Jingmei
Al-Haddad, Mohammad
Canto, Marcia Irene
Salamone, Ashley
Hruban, Ralph H.
Messallam, Ahmed A.
Khashab, Mouen A.
author_sort DeWitt, John
collection PubMed
description Background and study aims: The optimal core biopsy needle for endoscopic ultrasound (EUS) is unknown. The principle aim of this study is to compare outcomes of EUS-fine-needle biopsy (EUS-FNB) with a new 19-gauge EUS histology needle (ProCore, Cook Medical Inc., Winston-Salem, North Carolina, United States) to a conventional 19-gauge Tru-Cut biopsy (EUS-TCB) needle (19G, Quick-Core, Cook Medical Inc.). Patients and methods: Patients referred for EUS who require possible histologic biopsy were prospectively randomized to EUS-FNB or EUS-TCB. With the initial needle, ≤ 3 biopsies were obtained until either technical failure or an adequate core was obtained. Patients with suspected inadequate biopsies were crossed over to the other needle and similarly ≤ 3 passes were obtained until adequate cores or technical failure occurred. Technical success, diagnostic histology, accuracy and complication rates were evaluated. Results: Eighty-five patients (mean 58 years; 43 male) were randomized to FNB (n = 44) and TCB (n = 41) with seven patients excluded. Procedure indication, biopsy site, mass size, number of passes, puncture site, overall technical success and adverse events were similar between the two groups. FNB specimens had a higher prevalence of diagnostic histology (85 % vs. 57 %; P = 0.006), accuracy (88 % vs. 62 %; P = 0.02), mean total length (19.4 vs. 4.3 mm; P = 0.001), mean complete portal triads from liver biopsies (10.4 vs. 1.3; P = 0.0004) and required fewer crossover biopsies compared to those of TCB (2 % vs. 65 %; P = 0.0001). Overall technical success and complication rates were comparable. Conclusion: EUS-FNB using a 19-gauge FNB needle is superior to 19-gauge EUS-TCB needle.
format Online
Article
Text
id pubmed-4612231
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher © Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-46122312015-11-02 Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study DeWitt, John Cho, Chang-Min Lin, Jingmei Al-Haddad, Mohammad Canto, Marcia Irene Salamone, Ashley Hruban, Ralph H. Messallam, Ahmed A. Khashab, Mouen A. Endosc Int Open Article Background and study aims: The optimal core biopsy needle for endoscopic ultrasound (EUS) is unknown. The principle aim of this study is to compare outcomes of EUS-fine-needle biopsy (EUS-FNB) with a new 19-gauge EUS histology needle (ProCore, Cook Medical Inc., Winston-Salem, North Carolina, United States) to a conventional 19-gauge Tru-Cut biopsy (EUS-TCB) needle (19G, Quick-Core, Cook Medical Inc.). Patients and methods: Patients referred for EUS who require possible histologic biopsy were prospectively randomized to EUS-FNB or EUS-TCB. With the initial needle, ≤ 3 biopsies were obtained until either technical failure or an adequate core was obtained. Patients with suspected inadequate biopsies were crossed over to the other needle and similarly ≤ 3 passes were obtained until adequate cores or technical failure occurred. Technical success, diagnostic histology, accuracy and complication rates were evaluated. Results: Eighty-five patients (mean 58 years; 43 male) were randomized to FNB (n = 44) and TCB (n = 41) with seven patients excluded. Procedure indication, biopsy site, mass size, number of passes, puncture site, overall technical success and adverse events were similar between the two groups. FNB specimens had a higher prevalence of diagnostic histology (85 % vs. 57 %; P = 0.006), accuracy (88 % vs. 62 %; P = 0.02), mean total length (19.4 vs. 4.3 mm; P = 0.001), mean complete portal triads from liver biopsies (10.4 vs. 1.3; P = 0.0004) and required fewer crossover biopsies compared to those of TCB (2 % vs. 65 %; P = 0.0001). Overall technical success and complication rates were comparable. Conclusion: EUS-FNB using a 19-gauge FNB needle is superior to 19-gauge EUS-TCB needle. © Georg Thieme Verlag KG 2015-10 2015-06-24 /pmc/articles/PMC4612231/ /pubmed/26528504 http://dx.doi.org/10.1055/s-0034-1392222 Text en © Thieme Medical Publishers
spellingShingle Article
DeWitt, John
Cho, Chang-Min
Lin, Jingmei
Al-Haddad, Mohammad
Canto, Marcia Irene
Salamone, Ashley
Hruban, Ralph H.
Messallam, Ahmed A.
Khashab, Mouen A.
Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study
title Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study
title_full Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study
title_fullStr Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study
title_full_unstemmed Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study
title_short Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study
title_sort comparison of eus-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4612231/
https://www.ncbi.nlm.nih.gov/pubmed/26528504
http://dx.doi.org/10.1055/s-0034-1392222
work_keys_str_mv AT dewittjohn comparisonofeusguidedtissueacquisitionusingtwodifferent19gaugecorebiopsyneedlesamulticenterprospectiverandomizedandblindedstudy
AT chochangmin comparisonofeusguidedtissueacquisitionusingtwodifferent19gaugecorebiopsyneedlesamulticenterprospectiverandomizedandblindedstudy
AT linjingmei comparisonofeusguidedtissueacquisitionusingtwodifferent19gaugecorebiopsyneedlesamulticenterprospectiverandomizedandblindedstudy
AT alhaddadmohammad comparisonofeusguidedtissueacquisitionusingtwodifferent19gaugecorebiopsyneedlesamulticenterprospectiverandomizedandblindedstudy
AT cantomarciairene comparisonofeusguidedtissueacquisitionusingtwodifferent19gaugecorebiopsyneedlesamulticenterprospectiverandomizedandblindedstudy
AT salamoneashley comparisonofeusguidedtissueacquisitionusingtwodifferent19gaugecorebiopsyneedlesamulticenterprospectiverandomizedandblindedstudy
AT hrubanralphh comparisonofeusguidedtissueacquisitionusingtwodifferent19gaugecorebiopsyneedlesamulticenterprospectiverandomizedandblindedstudy
AT messallamahmeda comparisonofeusguidedtissueacquisitionusingtwodifferent19gaugecorebiopsyneedlesamulticenterprospectiverandomizedandblindedstudy
AT khashabmouena comparisonofeusguidedtissueacquisitionusingtwodifferent19gaugecorebiopsyneedlesamulticenterprospectiverandomizedandblindedstudy