Cargando…

Setup Error and Effectiveness of Weekly Image-Guided Radiation Therapy of TomoDirect for Early Breast Cancer

PURPOSE: This study investigated setup error and effectiveness of weekly image-guided radiotherapy (IGRT) of TomoDirect for early breast cancer. MATERIALS AND METHODS: One hundred and fifty-one breasts of 147 consecutive patients who underwent breast conserving surgery followed by whole breast irrad...

Descripción completa

Detalles Bibliográficos
Autores principales: Chung, Mi Joo, Lee, Guk Jin, Suh, Young Jin, Lee, Hyo Chun, Lee, Sea-Won, Jeong, Songmi, Lee, Jeong Won, Kim, Sung Hwan, Kang, Dae Gyu, Lee, Jong Hoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Cancer Association 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4614198/
https://www.ncbi.nlm.nih.gov/pubmed/25687857
http://dx.doi.org/10.4143/crt.2014.189
_version_ 1782396365531250688
author Chung, Mi Joo
Lee, Guk Jin
Suh, Young Jin
Lee, Hyo Chun
Lee, Sea-Won
Jeong, Songmi
Lee, Jeong Won
Kim, Sung Hwan
Kang, Dae Gyu
Lee, Jong Hoon
author_facet Chung, Mi Joo
Lee, Guk Jin
Suh, Young Jin
Lee, Hyo Chun
Lee, Sea-Won
Jeong, Songmi
Lee, Jeong Won
Kim, Sung Hwan
Kang, Dae Gyu
Lee, Jong Hoon
author_sort Chung, Mi Joo
collection PubMed
description PURPOSE: This study investigated setup error and effectiveness of weekly image-guided radiotherapy (IGRT) of TomoDirect for early breast cancer. MATERIALS AND METHODS: One hundred and fifty-one breasts of 147 consecutive patients who underwent breast conserving surgery followed by whole breast irradiation using TomoDirect in 2012 and 2013 were evaluated. All patients received weekly IGRT. The weekly setup errors from simulation to each treatment in reference to chest wall and surgical clips were measured. Random, systemic, and 3-dimensional setup errors were assessed. Extensive setup error was defined as 5 mm above the margin in any directions. RESULTS: All mean errors were within 3 mm of all directions. The mean angle of gantry shifts was 0.6°. The mean value of absolute 3-dimensional setup error was 4.67 mm. In multivariate analysis, breast size (odds ratio, 2.82; 95% confidence interval, 1.00 to 7.90) was a significant factor for extensive error. The largest significant deviation of setup error was observed in the first week of radiotherapy (p < 0.001) and the deviations gradually decreased with time. The deviation of setup error was 5.68 mm in the first week and within 5 mm after the second week. CONCLUSION: In this study, there was a significant association between breast size and significant setup error in breast cancer patients who received TomoDirect. The largest deviation occurred in the first week of treatment. Therefore, patients with large breasts should be closely observed on every fraction and fastidious attention is required in the first fraction of IGRT.
format Online
Article
Text
id pubmed-4614198
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Korean Cancer Association
record_format MEDLINE/PubMed
spelling pubmed-46141982015-10-22 Setup Error and Effectiveness of Weekly Image-Guided Radiation Therapy of TomoDirect for Early Breast Cancer Chung, Mi Joo Lee, Guk Jin Suh, Young Jin Lee, Hyo Chun Lee, Sea-Won Jeong, Songmi Lee, Jeong Won Kim, Sung Hwan Kang, Dae Gyu Lee, Jong Hoon Cancer Res Treat Original Article PURPOSE: This study investigated setup error and effectiveness of weekly image-guided radiotherapy (IGRT) of TomoDirect for early breast cancer. MATERIALS AND METHODS: One hundred and fifty-one breasts of 147 consecutive patients who underwent breast conserving surgery followed by whole breast irradiation using TomoDirect in 2012 and 2013 were evaluated. All patients received weekly IGRT. The weekly setup errors from simulation to each treatment in reference to chest wall and surgical clips were measured. Random, systemic, and 3-dimensional setup errors were assessed. Extensive setup error was defined as 5 mm above the margin in any directions. RESULTS: All mean errors were within 3 mm of all directions. The mean angle of gantry shifts was 0.6°. The mean value of absolute 3-dimensional setup error was 4.67 mm. In multivariate analysis, breast size (odds ratio, 2.82; 95% confidence interval, 1.00 to 7.90) was a significant factor for extensive error. The largest significant deviation of setup error was observed in the first week of radiotherapy (p < 0.001) and the deviations gradually decreased with time. The deviation of setup error was 5.68 mm in the first week and within 5 mm after the second week. CONCLUSION: In this study, there was a significant association between breast size and significant setup error in breast cancer patients who received TomoDirect. The largest deviation occurred in the first week of treatment. Therefore, patients with large breasts should be closely observed on every fraction and fastidious attention is required in the first fraction of IGRT. Korean Cancer Association 2015-10 2015-02-13 /pmc/articles/PMC4614198/ /pubmed/25687857 http://dx.doi.org/10.4143/crt.2014.189 Text en Copyright © 2015 by the Korean Cancer Association This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Chung, Mi Joo
Lee, Guk Jin
Suh, Young Jin
Lee, Hyo Chun
Lee, Sea-Won
Jeong, Songmi
Lee, Jeong Won
Kim, Sung Hwan
Kang, Dae Gyu
Lee, Jong Hoon
Setup Error and Effectiveness of Weekly Image-Guided Radiation Therapy of TomoDirect for Early Breast Cancer
title Setup Error and Effectiveness of Weekly Image-Guided Radiation Therapy of TomoDirect for Early Breast Cancer
title_full Setup Error and Effectiveness of Weekly Image-Guided Radiation Therapy of TomoDirect for Early Breast Cancer
title_fullStr Setup Error and Effectiveness of Weekly Image-Guided Radiation Therapy of TomoDirect for Early Breast Cancer
title_full_unstemmed Setup Error and Effectiveness of Weekly Image-Guided Radiation Therapy of TomoDirect for Early Breast Cancer
title_short Setup Error and Effectiveness of Weekly Image-Guided Radiation Therapy of TomoDirect for Early Breast Cancer
title_sort setup error and effectiveness of weekly image-guided radiation therapy of tomodirect for early breast cancer
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4614198/
https://www.ncbi.nlm.nih.gov/pubmed/25687857
http://dx.doi.org/10.4143/crt.2014.189
work_keys_str_mv AT chungmijoo setuperrorandeffectivenessofweeklyimageguidedradiationtherapyoftomodirectforearlybreastcancer
AT leegukjin setuperrorandeffectivenessofweeklyimageguidedradiationtherapyoftomodirectforearlybreastcancer
AT suhyoungjin setuperrorandeffectivenessofweeklyimageguidedradiationtherapyoftomodirectforearlybreastcancer
AT leehyochun setuperrorandeffectivenessofweeklyimageguidedradiationtherapyoftomodirectforearlybreastcancer
AT leeseawon setuperrorandeffectivenessofweeklyimageguidedradiationtherapyoftomodirectforearlybreastcancer
AT jeongsongmi setuperrorandeffectivenessofweeklyimageguidedradiationtherapyoftomodirectforearlybreastcancer
AT leejeongwon setuperrorandeffectivenessofweeklyimageguidedradiationtherapyoftomodirectforearlybreastcancer
AT kimsunghwan setuperrorandeffectivenessofweeklyimageguidedradiationtherapyoftomodirectforearlybreastcancer
AT kangdaegyu setuperrorandeffectivenessofweeklyimageguidedradiationtherapyoftomodirectforearlybreastcancer
AT leejonghoon setuperrorandeffectivenessofweeklyimageguidedradiationtherapyoftomodirectforearlybreastcancer