Cargando…

A comparison of hyperelastic constitutive models applicable to brain and fat tissues

In some soft biological structures such as brain and fat tissues, strong experimental evidence suggests that the shear modulus increases significantly under increasing compressive strain, but not under tensile strain, whereas the apparent Young's elastic modulus increases or remains almost cons...

Descripción completa

Detalles Bibliográficos
Autores principales: Mihai, L. Angela, Chin, LiKang, Janmey, Paul A., Goriely, Alain
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4614457/
https://www.ncbi.nlm.nih.gov/pubmed/26354826
http://dx.doi.org/10.1098/rsif.2015.0486
_version_ 1782396389601312768
author Mihai, L. Angela
Chin, LiKang
Janmey, Paul A.
Goriely, Alain
author_facet Mihai, L. Angela
Chin, LiKang
Janmey, Paul A.
Goriely, Alain
author_sort Mihai, L. Angela
collection PubMed
description In some soft biological structures such as brain and fat tissues, strong experimental evidence suggests that the shear modulus increases significantly under increasing compressive strain, but not under tensile strain, whereas the apparent Young's elastic modulus increases or remains almost constant when compressive strain increases. These tissues also exhibit a predominantly isotropic, incompressible behaviour. Our aim is to capture these seemingly contradictory mechanical behaviours, both qualitatively and quantitatively, within the framework of finite elasticity, by modelling a soft tissue as a homogeneous, isotropic, incompressible, hyperelastic material and comparing our results with available experimental data. Our analysis reveals that the Fung and Gent models, which are typically used to model soft tissues, are inadequate for the modelling of brain or fat under combined stretch and shear, and so are the classical neo-Hookean and Mooney–Rivlin models used for elastomers. However, a subclass of Ogden hyperelastic models are found to be in excellent agreement with the experiments. Our findings provide explicit models suitable for integration in large-scale finite-element computations.
format Online
Article
Text
id pubmed-4614457
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Royal Society
record_format MEDLINE/PubMed
spelling pubmed-46144572015-11-02 A comparison of hyperelastic constitutive models applicable to brain and fat tissues Mihai, L. Angela Chin, LiKang Janmey, Paul A. Goriely, Alain J R Soc Interface Research Articles In some soft biological structures such as brain and fat tissues, strong experimental evidence suggests that the shear modulus increases significantly under increasing compressive strain, but not under tensile strain, whereas the apparent Young's elastic modulus increases or remains almost constant when compressive strain increases. These tissues also exhibit a predominantly isotropic, incompressible behaviour. Our aim is to capture these seemingly contradictory mechanical behaviours, both qualitatively and quantitatively, within the framework of finite elasticity, by modelling a soft tissue as a homogeneous, isotropic, incompressible, hyperelastic material and comparing our results with available experimental data. Our analysis reveals that the Fung and Gent models, which are typically used to model soft tissues, are inadequate for the modelling of brain or fat under combined stretch and shear, and so are the classical neo-Hookean and Mooney–Rivlin models used for elastomers. However, a subclass of Ogden hyperelastic models are found to be in excellent agreement with the experiments. Our findings provide explicit models suitable for integration in large-scale finite-element computations. The Royal Society 2015-09-06 /pmc/articles/PMC4614457/ /pubmed/26354826 http://dx.doi.org/10.1098/rsif.2015.0486 Text en © 2015 The Authors. http://creativecommons.org/licenses/by/4.0/ Published by the Royal Society under the terms of the Creative Commons Attribution License http://creativecommons.org/licenses/by/4.0/, which permits unrestricted use, provided the original author and source are credited.
spellingShingle Research Articles
Mihai, L. Angela
Chin, LiKang
Janmey, Paul A.
Goriely, Alain
A comparison of hyperelastic constitutive models applicable to brain and fat tissues
title A comparison of hyperelastic constitutive models applicable to brain and fat tissues
title_full A comparison of hyperelastic constitutive models applicable to brain and fat tissues
title_fullStr A comparison of hyperelastic constitutive models applicable to brain and fat tissues
title_full_unstemmed A comparison of hyperelastic constitutive models applicable to brain and fat tissues
title_short A comparison of hyperelastic constitutive models applicable to brain and fat tissues
title_sort comparison of hyperelastic constitutive models applicable to brain and fat tissues
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4614457/
https://www.ncbi.nlm.nih.gov/pubmed/26354826
http://dx.doi.org/10.1098/rsif.2015.0486
work_keys_str_mv AT mihailangela acomparisonofhyperelasticconstitutivemodelsapplicabletobrainandfattissues
AT chinlikang acomparisonofhyperelasticconstitutivemodelsapplicabletobrainandfattissues
AT janmeypaula acomparisonofhyperelasticconstitutivemodelsapplicabletobrainandfattissues
AT gorielyalain acomparisonofhyperelasticconstitutivemodelsapplicabletobrainandfattissues
AT mihailangela comparisonofhyperelasticconstitutivemodelsapplicabletobrainandfattissues
AT chinlikang comparisonofhyperelasticconstitutivemodelsapplicabletobrainandfattissues
AT janmeypaula comparisonofhyperelasticconstitutivemodelsapplicabletobrainandfattissues
AT gorielyalain comparisonofhyperelasticconstitutivemodelsapplicabletobrainandfattissues