Cargando…

Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure

INTRODUCTION: Elevated intracranial pressure (ICP) is a major and potentially lethal disorder in patients admitted to the emergency department (ED). Several methods are being used to investigate for elevated ICP. Here we assessed and compared the diagnostic accuracy of two existing tools of ophthalm...

Descripción completa

Detalles Bibliográficos
Autores principales: Golshani, Keihan, Ebrahim zadeh, Mehdi, Farajzadegan, Ziba, Khorvash, Fariborz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shahid Beheshti University of Medical Sciences 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4614598/
https://www.ncbi.nlm.nih.gov/pubmed/26495382
_version_ 1782396408070930432
author Golshani, Keihan
Ebrahim zadeh, Mehdi
Farajzadegan, Ziba
Khorvash, Fariborz
author_facet Golshani, Keihan
Ebrahim zadeh, Mehdi
Farajzadegan, Ziba
Khorvash, Fariborz
author_sort Golshani, Keihan
collection PubMed
description INTRODUCTION: Elevated intracranial pressure (ICP) is a major and potentially lethal disorder in patients admitted to the emergency department (ED). Several methods are being used to investigate for elevated ICP. Here we assessed and compared the diagnostic accuracy of two existing tools of ophthalmoscopy and optic nerve ultrasonography in detection of elevated ICP. METHODS: 131 participants with probable elevation of ICP referred to the emergency department of Al-Zahra Hospital, Isfahan, Iran, from 2012 to 2014, were enrolled. Brain computed tomography (CT) scan, ultrasonography of optic nerve sheath, and ophthalmoscopy were performed for them. The optic nerves sheath with diameter more than 5 millimeters was considered as elevated ICP. Widening of optic nerve, ocular venous engorgement, blurring, hemorrhage over optic disk, elevation of optic disk, and retinal venous tortuosity were recorded as evidences of ICP rising in ophthalmoscopy. Diagnostic accuracy of the two tools in prediction of ICP rising were compared with the results of brain CT scan as a gold standard. RESULTS: The mean age of participants was 46.29 ± 10 years (77% male). The number of diagnosed elevated ICPs with ophthalmoscopy and ultrasound were 98 (74.8%) and 102 (77.9%) cases, respectively. The calculated sensitivity and specificity of ophthalmoscopy and ultrasonography in detection of ICP rising were 100.0% (95% CI: 88.6-100.0) and 35.4% (95% CI: 26.0-46.2), 100.0% (95% CI: 84.0-100.0) and 31.9% (95% CI: 23.0-41.7), respectively. CONCLUSION: The present study revealed that bedside ultrasonography of optic nerve sheath and ophthalmoscopy have enough accuracy for the screening of patients with probable elevation of ICP. Of course, it should be considered that despite the high sensitivity of both tools, their specificity is low.
format Online
Article
Text
id pubmed-4614598
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Shahid Beheshti University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-46145982015-10-22 Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure Golshani, Keihan Ebrahim zadeh, Mehdi Farajzadegan, Ziba Khorvash, Fariborz Emerg (Tehran) Original Article INTRODUCTION: Elevated intracranial pressure (ICP) is a major and potentially lethal disorder in patients admitted to the emergency department (ED). Several methods are being used to investigate for elevated ICP. Here we assessed and compared the diagnostic accuracy of two existing tools of ophthalmoscopy and optic nerve ultrasonography in detection of elevated ICP. METHODS: 131 participants with probable elevation of ICP referred to the emergency department of Al-Zahra Hospital, Isfahan, Iran, from 2012 to 2014, were enrolled. Brain computed tomography (CT) scan, ultrasonography of optic nerve sheath, and ophthalmoscopy were performed for them. The optic nerves sheath with diameter more than 5 millimeters was considered as elevated ICP. Widening of optic nerve, ocular venous engorgement, blurring, hemorrhage over optic disk, elevation of optic disk, and retinal venous tortuosity were recorded as evidences of ICP rising in ophthalmoscopy. Diagnostic accuracy of the two tools in prediction of ICP rising were compared with the results of brain CT scan as a gold standard. RESULTS: The mean age of participants was 46.29 ± 10 years (77% male). The number of diagnosed elevated ICPs with ophthalmoscopy and ultrasound were 98 (74.8%) and 102 (77.9%) cases, respectively. The calculated sensitivity and specificity of ophthalmoscopy and ultrasonography in detection of ICP rising were 100.0% (95% CI: 88.6-100.0) and 35.4% (95% CI: 26.0-46.2), 100.0% (95% CI: 84.0-100.0) and 31.9% (95% CI: 23.0-41.7), respectively. CONCLUSION: The present study revealed that bedside ultrasonography of optic nerve sheath and ophthalmoscopy have enough accuracy for the screening of patients with probable elevation of ICP. Of course, it should be considered that despite the high sensitivity of both tools, their specificity is low. Shahid Beheshti University of Medical Sciences 2015 /pmc/articles/PMC4614598/ /pubmed/26495382 Text en © 2015 Shahid Beheshti University of Medical Sciences. All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), (http://creativecommons.org/licenses/by-nc/3.0/)which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Golshani, Keihan
Ebrahim zadeh, Mehdi
Farajzadegan, Ziba
Khorvash, Fariborz
Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure
title Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure
title_full Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure
title_fullStr Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure
title_full_unstemmed Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure
title_short Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure
title_sort diagnostic accuracy of optic nerve ultrasonography and ophthalmoscopy in prediction of elevated intracranial pressure
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4614598/
https://www.ncbi.nlm.nih.gov/pubmed/26495382
work_keys_str_mv AT golshanikeihan diagnosticaccuracyofopticnerveultrasonographyandophthalmoscopyinpredictionofelevatedintracranialpressure
AT ebrahimzadehmehdi diagnosticaccuracyofopticnerveultrasonographyandophthalmoscopyinpredictionofelevatedintracranialpressure
AT farajzadeganziba diagnosticaccuracyofopticnerveultrasonographyandophthalmoscopyinpredictionofelevatedintracranialpressure
AT khorvashfariborz diagnosticaccuracyofopticnerveultrasonographyandophthalmoscopyinpredictionofelevatedintracranialpressure