Cargando…

MR diffusion-weighted imaging-based subcutaneous tumour volumetry in a xenografted nude mouse model using 3D Slicer: an accurate and repeatable method

Accurate and repeatable measurement of the gross tumour volume(GTV) of subcutaneous xenografts is crucial in the evaluation of anti-tumour therapy. Formula and image-based manual segmentation methods are commonly used for GTV measurement but are hindered by low accuracy and reproducibility. 3D Slice...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Zelan, Chen, Xin, Huang, Yanqi, He, Lan, Liang, Cuishan, Liang, Changhong, Liu, Zaiyi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4614907/
https://www.ncbi.nlm.nih.gov/pubmed/26489359
http://dx.doi.org/10.1038/srep15653
_version_ 1782396444664135680
author Ma, Zelan
Chen, Xin
Huang, Yanqi
He, Lan
Liang, Cuishan
Liang, Changhong
Liu, Zaiyi
author_facet Ma, Zelan
Chen, Xin
Huang, Yanqi
He, Lan
Liang, Cuishan
Liang, Changhong
Liu, Zaiyi
author_sort Ma, Zelan
collection PubMed
description Accurate and repeatable measurement of the gross tumour volume(GTV) of subcutaneous xenografts is crucial in the evaluation of anti-tumour therapy. Formula and image-based manual segmentation methods are commonly used for GTV measurement but are hindered by low accuracy and reproducibility. 3D Slicer is open-source software that provides semiautomatic segmentation for GTV measurements. In our study, subcutaneous GTVs from nude mouse xenografts were measured by semiautomatic segmentation with 3D Slicer based on morphological magnetic resonance imaging(mMRI) or diffusion-weighted imaging(DWI)(b = 0,20,800 s/mm(2)) . These GTVs were then compared with those obtained via the formula and image-based manual segmentation methods with ITK software using the true tumour volume as the standard reference. The effects of tumour size and shape on GTVs measurements were also investigated. Our results showed that, when compared with the true tumour volume, segmentation for DWI(P = 0.060–0.671) resulted in better accuracy than that mMRI(P < 0.001) and the formula method(P < 0.001). Furthermore, semiautomatic segmentation for DWI(intraclass correlation coefficient, ICC = 0.9999) resulted in higher reliability than manual segmentation(ICC = 0.9996–0.9998). Tumour size and shape had no effects on GTV measurement across all methods. Therefore, DWI-based semiautomatic segmentation, which is accurate and reproducible and also provides biological information, is the optimal GTV measurement method in the assessment of anti-tumour treatments.
format Online
Article
Text
id pubmed-4614907
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-46149072015-10-29 MR diffusion-weighted imaging-based subcutaneous tumour volumetry in a xenografted nude mouse model using 3D Slicer: an accurate and repeatable method Ma, Zelan Chen, Xin Huang, Yanqi He, Lan Liang, Cuishan Liang, Changhong Liu, Zaiyi Sci Rep Article Accurate and repeatable measurement of the gross tumour volume(GTV) of subcutaneous xenografts is crucial in the evaluation of anti-tumour therapy. Formula and image-based manual segmentation methods are commonly used for GTV measurement but are hindered by low accuracy and reproducibility. 3D Slicer is open-source software that provides semiautomatic segmentation for GTV measurements. In our study, subcutaneous GTVs from nude mouse xenografts were measured by semiautomatic segmentation with 3D Slicer based on morphological magnetic resonance imaging(mMRI) or diffusion-weighted imaging(DWI)(b = 0,20,800 s/mm(2)) . These GTVs were then compared with those obtained via the formula and image-based manual segmentation methods with ITK software using the true tumour volume as the standard reference. The effects of tumour size and shape on GTVs measurements were also investigated. Our results showed that, when compared with the true tumour volume, segmentation for DWI(P = 0.060–0.671) resulted in better accuracy than that mMRI(P < 0.001) and the formula method(P < 0.001). Furthermore, semiautomatic segmentation for DWI(intraclass correlation coefficient, ICC = 0.9999) resulted in higher reliability than manual segmentation(ICC = 0.9996–0.9998). Tumour size and shape had no effects on GTV measurement across all methods. Therefore, DWI-based semiautomatic segmentation, which is accurate and reproducible and also provides biological information, is the optimal GTV measurement method in the assessment of anti-tumour treatments. Nature Publishing Group 2015-10-22 /pmc/articles/PMC4614907/ /pubmed/26489359 http://dx.doi.org/10.1038/srep15653 Text en Copyright © 2015, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Ma, Zelan
Chen, Xin
Huang, Yanqi
He, Lan
Liang, Cuishan
Liang, Changhong
Liu, Zaiyi
MR diffusion-weighted imaging-based subcutaneous tumour volumetry in a xenografted nude mouse model using 3D Slicer: an accurate and repeatable method
title MR diffusion-weighted imaging-based subcutaneous tumour volumetry in a xenografted nude mouse model using 3D Slicer: an accurate and repeatable method
title_full MR diffusion-weighted imaging-based subcutaneous tumour volumetry in a xenografted nude mouse model using 3D Slicer: an accurate and repeatable method
title_fullStr MR diffusion-weighted imaging-based subcutaneous tumour volumetry in a xenografted nude mouse model using 3D Slicer: an accurate and repeatable method
title_full_unstemmed MR diffusion-weighted imaging-based subcutaneous tumour volumetry in a xenografted nude mouse model using 3D Slicer: an accurate and repeatable method
title_short MR diffusion-weighted imaging-based subcutaneous tumour volumetry in a xenografted nude mouse model using 3D Slicer: an accurate and repeatable method
title_sort mr diffusion-weighted imaging-based subcutaneous tumour volumetry in a xenografted nude mouse model using 3d slicer: an accurate and repeatable method
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4614907/
https://www.ncbi.nlm.nih.gov/pubmed/26489359
http://dx.doi.org/10.1038/srep15653
work_keys_str_mv AT mazelan mrdiffusionweightedimagingbasedsubcutaneoustumourvolumetryinaxenograftednudemousemodelusing3dsliceranaccurateandrepeatablemethod
AT chenxin mrdiffusionweightedimagingbasedsubcutaneoustumourvolumetryinaxenograftednudemousemodelusing3dsliceranaccurateandrepeatablemethod
AT huangyanqi mrdiffusionweightedimagingbasedsubcutaneoustumourvolumetryinaxenograftednudemousemodelusing3dsliceranaccurateandrepeatablemethod
AT helan mrdiffusionweightedimagingbasedsubcutaneoustumourvolumetryinaxenograftednudemousemodelusing3dsliceranaccurateandrepeatablemethod
AT liangcuishan mrdiffusionweightedimagingbasedsubcutaneoustumourvolumetryinaxenograftednudemousemodelusing3dsliceranaccurateandrepeatablemethod
AT liangchanghong mrdiffusionweightedimagingbasedsubcutaneoustumourvolumetryinaxenograftednudemousemodelusing3dsliceranaccurateandrepeatablemethod
AT liuzaiyi mrdiffusionweightedimagingbasedsubcutaneoustumourvolumetryinaxenograftednudemousemodelusing3dsliceranaccurateandrepeatablemethod