Application of Additional Medial Plate in Treatment of Proximal Humeral Fractures With Unstable Medial Column: A Finite Element Study and Clinical Practice
The purpose of this study was to use finite element analysis to compare the biomechanical characteristics after lateral locking plate (LLP) or LLP with a medial anatomical locking plate (LLP-MLP) fixation of proximal humeral fractures with an unstable medial column. First, a 3-dimensional, finite el...
Autores principales: | He, Yu, He, Jiliang, Wang, Fu, Zhou, Dongsheng, Wang, Yan, Wang, Bomin, Xu, Shihong |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4616805/ https://www.ncbi.nlm.nih.gov/pubmed/26469918 http://dx.doi.org/10.1097/MD.0000000000001775 |
Ejemplares similares
-
Treatment of medial humeral epicondyle fractures in children using absorbable self-reinforced polylactide pins
por: Su, Yuxi, et al.
Publicado: (2020) -
Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study
por: Chen, Xiong, et al.
Publicado: (2019) -
Bipolar clavicle fractures treatment using medial and lateral double plates: A case report
por: Xing, Haiyang, et al.
Publicado: (2022) -
Medial Calcar Support and Radiographic Outcomes of Plate Fixation for Proximal Humeral Fractures
por: Lin, Shih-Jie, et al.
Publicado: (2015) -
The effect of medial calcar support on proximal humeral fractures treated with locking plates
por: Hung, Chun-Yu, et al.
Publicado: (2022)