Cargando…

Hippocampal volume and hippocampal angle (a more practical marker) in mild cognitive impairment: A case-control magnetic resonance imaging study

BACKGROUND: Mild cognitive impairment (MCI) accompanies brain atrophy in neuroimaging investigations. The aim of this study was to compare MCI patients with the normal population for hippocampal volume (HV) and hippocampal angle (HA), and to assess the correlation between HV and HA. MATERIALS AND ME...

Descripción completa

Detalles Bibliográficos
Autores principales: Basiratnia, Reza, Amini, Ehsan, Sharbafchi, Mohammad Reza, Maracy, Mohammad, Barekatain, Majid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4617004/
https://www.ncbi.nlm.nih.gov/pubmed/26605231
http://dx.doi.org/10.4103/2277-9175.166153
_version_ 1782396742894878720
author Basiratnia, Reza
Amini, Ehsan
Sharbafchi, Mohammad Reza
Maracy, Mohammad
Barekatain, Majid
author_facet Basiratnia, Reza
Amini, Ehsan
Sharbafchi, Mohammad Reza
Maracy, Mohammad
Barekatain, Majid
author_sort Basiratnia, Reza
collection PubMed
description BACKGROUND: Mild cognitive impairment (MCI) accompanies brain atrophy in neuroimaging investigations. The aim of this study was to compare MCI patients with the normal population for hippocampal volume (HV) and hippocampal angle (HA), and to assess the correlation between HV and HA. MATERIALS AND METHODS: In a case-control study on 2014, in Kashani Hospital (Isfahan, Iran), 20 MCI patients were compared with 20 normal controls for HV and HA. Subjects were diagnosed with MCI or normal control, based on neuropsychiatry interview, which was confirmed by neuropsychiatry unit cognitive assessment tool (NUCOG). All magnetic resonance imaging scans were processed using the Free-Surfer software package for HV assessment. The HA was measured on the most rostral slice in which the uncal sulcus could be identified on a coronal plane. The data were analyzed using multiple analysis of co-variance and Pearson correlation. RESULTS: The mean (standard deviation [SD]) score of NUCOG in control and case group were 91.05 (3.01) and 82.42 (3.57), respectively. Comparison of HV and HA scores in two groups, showed that mean (SD) HV and HA were not different between control and case groups, significantly, (P = 0.094 and P = 0.394, respectively). There was a negative correlation between the adjusted HV and the HA in case (r = −0.642, P = 0.004), and control groups (r = −0.654, P = 0.003). CONCLUSION: HV and HA were not different between MCI patients and normal controls; however, HA is correlated with HV negatively and may be used as an alternative factor because of more feasibility and availability in clinical settings in compared to HV.
format Online
Article
Text
id pubmed-4617004
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-46170042015-11-24 Hippocampal volume and hippocampal angle (a more practical marker) in mild cognitive impairment: A case-control magnetic resonance imaging study Basiratnia, Reza Amini, Ehsan Sharbafchi, Mohammad Reza Maracy, Mohammad Barekatain, Majid Adv Biomed Res Original Article BACKGROUND: Mild cognitive impairment (MCI) accompanies brain atrophy in neuroimaging investigations. The aim of this study was to compare MCI patients with the normal population for hippocampal volume (HV) and hippocampal angle (HA), and to assess the correlation between HV and HA. MATERIALS AND METHODS: In a case-control study on 2014, in Kashani Hospital (Isfahan, Iran), 20 MCI patients were compared with 20 normal controls for HV and HA. Subjects were diagnosed with MCI or normal control, based on neuropsychiatry interview, which was confirmed by neuropsychiatry unit cognitive assessment tool (NUCOG). All magnetic resonance imaging scans were processed using the Free-Surfer software package for HV assessment. The HA was measured on the most rostral slice in which the uncal sulcus could be identified on a coronal plane. The data were analyzed using multiple analysis of co-variance and Pearson correlation. RESULTS: The mean (standard deviation [SD]) score of NUCOG in control and case group were 91.05 (3.01) and 82.42 (3.57), respectively. Comparison of HV and HA scores in two groups, showed that mean (SD) HV and HA were not different between control and case groups, significantly, (P = 0.094 and P = 0.394, respectively). There was a negative correlation between the adjusted HV and the HA in case (r = −0.642, P = 0.004), and control groups (r = −0.654, P = 0.003). CONCLUSION: HV and HA were not different between MCI patients and normal controls; however, HA is correlated with HV negatively and may be used as an alternative factor because of more feasibility and availability in clinical settings in compared to HV. Medknow Publications & Media Pvt Ltd 2015-09-28 /pmc/articles/PMC4617004/ /pubmed/26605231 http://dx.doi.org/10.4103/2277-9175.166153 Text en Copyright: © 2015 Advanced Biomedical Research http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Basiratnia, Reza
Amini, Ehsan
Sharbafchi, Mohammad Reza
Maracy, Mohammad
Barekatain, Majid
Hippocampal volume and hippocampal angle (a more practical marker) in mild cognitive impairment: A case-control magnetic resonance imaging study
title Hippocampal volume and hippocampal angle (a more practical marker) in mild cognitive impairment: A case-control magnetic resonance imaging study
title_full Hippocampal volume and hippocampal angle (a more practical marker) in mild cognitive impairment: A case-control magnetic resonance imaging study
title_fullStr Hippocampal volume and hippocampal angle (a more practical marker) in mild cognitive impairment: A case-control magnetic resonance imaging study
title_full_unstemmed Hippocampal volume and hippocampal angle (a more practical marker) in mild cognitive impairment: A case-control magnetic resonance imaging study
title_short Hippocampal volume and hippocampal angle (a more practical marker) in mild cognitive impairment: A case-control magnetic resonance imaging study
title_sort hippocampal volume and hippocampal angle (a more practical marker) in mild cognitive impairment: a case-control magnetic resonance imaging study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4617004/
https://www.ncbi.nlm.nih.gov/pubmed/26605231
http://dx.doi.org/10.4103/2277-9175.166153
work_keys_str_mv AT basiratniareza hippocampalvolumeandhippocampalangleamorepracticalmarkerinmildcognitiveimpairmentacasecontrolmagneticresonanceimagingstudy
AT aminiehsan hippocampalvolumeandhippocampalangleamorepracticalmarkerinmildcognitiveimpairmentacasecontrolmagneticresonanceimagingstudy
AT sharbafchimohammadreza hippocampalvolumeandhippocampalangleamorepracticalmarkerinmildcognitiveimpairmentacasecontrolmagneticresonanceimagingstudy
AT maracymohammad hippocampalvolumeandhippocampalangleamorepracticalmarkerinmildcognitiveimpairmentacasecontrolmagneticresonanceimagingstudy
AT barekatainmajid hippocampalvolumeandhippocampalangleamorepracticalmarkerinmildcognitiveimpairmentacasecontrolmagneticresonanceimagingstudy