Cargando…

Comparison of Different Double Immunostaining Protocols for Paraffin Embedded Liver Tissue

Most of the double immunostaining protocols that have been introduced so far have been developed for application on fresh frozen material or based on different species antibodies. In liver tissue, general problems of double immunostaining techniques are further complicated by tissue‐specific difficu...

Descripción completa

Detalles Bibliográficos
Autores principales: Schütz, Alexander, Tannapfel, Andrea, Wittekind, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IOS Press 1999
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4617801/
https://www.ncbi.nlm.nih.gov/pubmed/10609566
http://dx.doi.org/10.1155/1999/697310
_version_ 1782396839169884160
author Schütz, Alexander
Tannapfel, Andrea
Wittekind, Christian
author_facet Schütz, Alexander
Tannapfel, Andrea
Wittekind, Christian
author_sort Schütz, Alexander
collection PubMed
description Most of the double immunostaining protocols that have been introduced so far have been developed for application on fresh frozen material or based on different species antibodies. In liver tissue, general problems of double immunostaining techniques are further complicated by tissue‐specific difficulties, such as necrosis or high intracellular protein content. To assess a reliable double immunostaining protocol for archived, paraffin embedded liver tissue, different protocols based on the use of same species primary antibodies were evaluated in terms of sensitivity, specificity and non‐specific background staining in pathological liver specimens. We compared peroxidase–anti‐peroxidase, alkaline phosphatase–anti‐alkaline phosphatase (PAP/APAP), labelled‐avidin–biotin (LAB/LAB) and digoxigenin–anti‐digoxigenin (dig–a‐dig/PAP) techniques using different cytokeratin antibodies and an antibody against PCNA. Comparison of the double immunostaining techniques revealed a high sensitivity and specificity in all procedures. Sections, which were stained employing PAP/APAP‐technique, displayed a higher background staining compared to sections which were treated with the LAB/LAB or dig–a‐dig/PAP protocol. In contrast to the dig–a‐dig/PAP protocol, the LAB/LAB technique provides a better time/cost relationship. Therefore, we would like to recommend a modified LAB/LAB protocol for simultaneous detection of different antigens in archived liver tissue.
format Online
Article
Text
id pubmed-4617801
institution National Center for Biotechnology Information
language English
publishDate 1999
publisher IOS Press
record_format MEDLINE/PubMed
spelling pubmed-46178012016-01-12 Comparison of Different Double Immunostaining Protocols for Paraffin Embedded Liver Tissue Schütz, Alexander Tannapfel, Andrea Wittekind, Christian Anal Cell Pathol Other Most of the double immunostaining protocols that have been introduced so far have been developed for application on fresh frozen material or based on different species antibodies. In liver tissue, general problems of double immunostaining techniques are further complicated by tissue‐specific difficulties, such as necrosis or high intracellular protein content. To assess a reliable double immunostaining protocol for archived, paraffin embedded liver tissue, different protocols based on the use of same species primary antibodies were evaluated in terms of sensitivity, specificity and non‐specific background staining in pathological liver specimens. We compared peroxidase–anti‐peroxidase, alkaline phosphatase–anti‐alkaline phosphatase (PAP/APAP), labelled‐avidin–biotin (LAB/LAB) and digoxigenin–anti‐digoxigenin (dig–a‐dig/PAP) techniques using different cytokeratin antibodies and an antibody against PCNA. Comparison of the double immunostaining techniques revealed a high sensitivity and specificity in all procedures. Sections, which were stained employing PAP/APAP‐technique, displayed a higher background staining compared to sections which were treated with the LAB/LAB or dig–a‐dig/PAP protocol. In contrast to the dig–a‐dig/PAP protocol, the LAB/LAB technique provides a better time/cost relationship. Therefore, we would like to recommend a modified LAB/LAB protocol for simultaneous detection of different antigens in archived liver tissue. IOS Press 1999 1999-01-01 /pmc/articles/PMC4617801/ /pubmed/10609566 http://dx.doi.org/10.1155/1999/697310 Text en Copyright © 1999 Hindawi Publishing Corporation.
spellingShingle Other
Schütz, Alexander
Tannapfel, Andrea
Wittekind, Christian
Comparison of Different Double Immunostaining Protocols for Paraffin Embedded Liver Tissue
title Comparison of Different Double Immunostaining Protocols for Paraffin Embedded Liver Tissue
title_full Comparison of Different Double Immunostaining Protocols for Paraffin Embedded Liver Tissue
title_fullStr Comparison of Different Double Immunostaining Protocols for Paraffin Embedded Liver Tissue
title_full_unstemmed Comparison of Different Double Immunostaining Protocols for Paraffin Embedded Liver Tissue
title_short Comparison of Different Double Immunostaining Protocols for Paraffin Embedded Liver Tissue
title_sort comparison of different double immunostaining protocols for paraffin embedded liver tissue
topic Other
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4617801/
https://www.ncbi.nlm.nih.gov/pubmed/10609566
http://dx.doi.org/10.1155/1999/697310
work_keys_str_mv AT schutzalexander comparisonofdifferentdoubleimmunostainingprotocolsforparaffinembeddedlivertissue
AT tannapfelandrea comparisonofdifferentdoubleimmunostainingprotocolsforparaffinembeddedlivertissue
AT wittekindchristian comparisonofdifferentdoubleimmunostainingprotocolsforparaffinembeddedlivertissue