Cargando…

Secondary Radial Nerve Palsy after Minimally Invasive Plate Osteosynthesis of a Distal Humeral Shaft Fracture

Minimally invasive plate osteosynthesis is a widely used procedure for the treatment of fractures of the femur and the tibia. For a short time it is also used for the treatment of humeral shaft fractures. Among other advantages, the ambassadors of this technique emphasize the lower risk of nerve inj...

Descripción completa

Detalles Bibliográficos
Autores principales: Bichsel, Ursina, Nyffeler, Richard Walter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4618116/
https://www.ncbi.nlm.nih.gov/pubmed/26558125
http://dx.doi.org/10.1155/2015/241968
Descripción
Sumario:Minimally invasive plate osteosynthesis is a widely used procedure for the treatment of fractures of the femur and the tibia. For a short time it is also used for the treatment of humeral shaft fractures. Among other advantages, the ambassadors of this technique emphasize the lower risk of nerve injuries when compared to open reduction and internal fixation. We report the case of secondary radial nerve palsy caused by percutaneous fixation of a plate above the antecubital fold. The nerve did not recover and the patient needed a tendon transfer to regain active extension of the fingers. This case points to the importance of adequate exposure of the bone and plate if a humeral shaft fracture extends far distally.