Torque Analysis of a Triple Acid-Etched Titanium Implant Surface

The present study aimed to evaluate the removal torque of titanium implants treated with triple acid etching. Twenty-one rats were used in this study. For all animals, the tibia was prepared with a 2 mm drill, and a titanium implant (2 × 4 mm) was inserted after treatment using the subtraction metho...

Descripción completa

Detalles Bibliográficos
Autores principales: Pontes, Ana Emília Farias, de Toledo, Cássio Torres, Garcia, Valdir Gouveia, Ribeiro, Fernando Salimon, Sakakura, Celso Eduardo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4620380/
https://www.ncbi.nlm.nih.gov/pubmed/26543898
http://dx.doi.org/10.1155/2015/819879
_version_ 1782397285293883392
author Pontes, Ana Emília Farias
de Toledo, Cássio Torres
Garcia, Valdir Gouveia
Ribeiro, Fernando Salimon
Sakakura, Celso Eduardo
author_facet Pontes, Ana Emília Farias
de Toledo, Cássio Torres
Garcia, Valdir Gouveia
Ribeiro, Fernando Salimon
Sakakura, Celso Eduardo
author_sort Pontes, Ana Emília Farias
collection PubMed
description The present study aimed to evaluate the removal torque of titanium implants treated with triple acid etching. Twenty-one rats were used in this study. For all animals, the tibia was prepared with a 2 mm drill, and a titanium implant (2 × 4 mm) was inserted after treatment using the subtraction method of triple acid etching. The flaps were sutured. Seven animals were killed 14, 28, and 63 days after implant installation, and the load necessary for removing the implant from the bone was evaluated by using a torque meter. The torque values were as follows: 3.3 ± 1.7 Ncm (14 days), 2.2 ± 1.3 Ncm (28 days), and 6.7 ± 1.4 Ncm (63 days). The torque value at the final healing period (63 days) was statistically significantly different from that at other time points tested (ANOVA, p = 0.0002). This preliminary study revealed that treatment with triple acid etching can create a promising and efficient surface for the process of osseointegration.
format Online
Article
Text
id pubmed-4620380
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-46203802015-11-05 Torque Analysis of a Triple Acid-Etched Titanium Implant Surface Pontes, Ana Emília Farias de Toledo, Cássio Torres Garcia, Valdir Gouveia Ribeiro, Fernando Salimon Sakakura, Celso Eduardo ScientificWorldJournal Research Article The present study aimed to evaluate the removal torque of titanium implants treated with triple acid etching. Twenty-one rats were used in this study. For all animals, the tibia was prepared with a 2 mm drill, and a titanium implant (2 × 4 mm) was inserted after treatment using the subtraction method of triple acid etching. The flaps were sutured. Seven animals were killed 14, 28, and 63 days after implant installation, and the load necessary for removing the implant from the bone was evaluated by using a torque meter. The torque values were as follows: 3.3 ± 1.7 Ncm (14 days), 2.2 ± 1.3 Ncm (28 days), and 6.7 ± 1.4 Ncm (63 days). The torque value at the final healing period (63 days) was statistically significantly different from that at other time points tested (ANOVA, p = 0.0002). This preliminary study revealed that treatment with triple acid etching can create a promising and efficient surface for the process of osseointegration. Hindawi Publishing Corporation 2015 2015-10-12 /pmc/articles/PMC4620380/ /pubmed/26543898 http://dx.doi.org/10.1155/2015/819879 Text en Copyright © 2015 Ana Emília Farias Pontes et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Pontes, Ana Emília Farias
de Toledo, Cássio Torres
Garcia, Valdir Gouveia
Ribeiro, Fernando Salimon
Sakakura, Celso Eduardo
Torque Analysis of a Triple Acid-Etched Titanium Implant Surface
title Torque Analysis of a Triple Acid-Etched Titanium Implant Surface
title_full Torque Analysis of a Triple Acid-Etched Titanium Implant Surface
title_fullStr Torque Analysis of a Triple Acid-Etched Titanium Implant Surface
title_full_unstemmed Torque Analysis of a Triple Acid-Etched Titanium Implant Surface
title_short Torque Analysis of a Triple Acid-Etched Titanium Implant Surface
title_sort torque analysis of a triple acid-etched titanium implant surface
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4620380/
https://www.ncbi.nlm.nih.gov/pubmed/26543898
http://dx.doi.org/10.1155/2015/819879
work_keys_str_mv AT pontesanaemiliafarias torqueanalysisofatripleacidetchedtitaniumimplantsurface
AT detoledocassiotorres torqueanalysisofatripleacidetchedtitaniumimplantsurface
AT garciavaldirgouveia torqueanalysisofatripleacidetchedtitaniumimplantsurface
AT ribeirofernandosalimon torqueanalysisofatripleacidetchedtitaniumimplantsurface
AT sakakuracelsoeduardo torqueanalysisofatripleacidetchedtitaniumimplantsurface