Cargando…
A simple modified Bentall technique for surgical reconstruction of the aortic root – short and long term outcomes
BACKGROUND: Since the first introduction of the Bentall technique, several modifications have been proposed to improve patient outcomes and decrease intra- and post-operative complications. We describe a simplified modification of the technique that tries to lessen the intra-operative time, improve...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4620649/ https://www.ncbi.nlm.nih.gov/pubmed/26502872 http://dx.doi.org/10.1186/s13019-015-0336-4 |
Sumario: | BACKGROUND: Since the first introduction of the Bentall technique, several modifications have been proposed to improve patient outcomes and decrease intra- and post-operative complications. We describe a simplified modification of the technique that tries to lessen the intra-operative time, improve homeostasis and miminize early and late complications. Our experience with the technique and short- and long-term patient outcomes are reported. METHODS: From August 1996 to October 2013, 110 consecutive patients underwent this modified technique. The procedure used Dacron composite graft with a mechanical valve (St. Jude Medical®) for aortic root replacement. To avoid intra-operative complications, no mobilization of coronary ostia was done. Additionally, the tubular aorta was kept minimally unchanged. RESULTS: Total bleeding after the operation was 450 ± 105 mL. The mean duration of intensive care unit and hospital stay were 2 ± 1 and 5 ± 2 days, respectively. Sixty-six patients (60 %) were discharged from the surgical intensive care unit on the first postoperative day, 34 patients (30.9 %) were discharged on the second day and ten patients (9.1 %) needed more time to stay in the intensive care unit due to haemodynamic or respiratory problems. At 5-years follow up, survival rate was 97 %. In the three deceased patients, causes of death were mediastinitis, sepsis and myocardial infarction. No operation-related complications such as anticoagulant-related hemorrhage, valve or graft thrombosis, or coronary pseudoaneurysm were occurred during follow-up. CONCLUSIONS: The proposed modification of the Bentall technique seems to minimize late intra-operative blood loss, improves homeostasis, shortens the operation time and is associated with excellent long-term outcomes in patients undergoing composite graft replacement of the aortic root. |
---|