Cargando…

Acoustic Radiation Force Impulse Elastography: A Useful Tool for Differential Diagnosis of Thyroid Nodules and Recommending Fine-Needle Aspiration: A Diagnostic Accuracy Study

To investigate the diagnostic performance of combined use of conventional ultrasound (US) and elastography, including conventional strain elastography such as elasticity imaging (EI) and acoustic radiation force impulse (ARFI) elastography, and to evaluate their usefulness in recommending fine-needl...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Yi-Feng, Xu, Jun-Mei, Xu, Hui-Xiong, Liu, Chang, Bo, Xiao-Wan, Li, Xiao-Long, Guo, Le-Hang, Liu, Bo-Ji, Liu, Lin-Na, Xu, Xiao-Hong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4620786/
https://www.ncbi.nlm.nih.gov/pubmed/26496325
http://dx.doi.org/10.1097/MD.0000000000001834
_version_ 1782397354356244480
author Zhang, Yi-Feng
Xu, Jun-Mei
Xu, Hui-Xiong
Liu, Chang
Bo, Xiao-Wan
Li, Xiao-Long
Guo, Le-Hang
Liu, Bo-Ji
Liu, Lin-Na
Xu, Xiao-Hong
author_facet Zhang, Yi-Feng
Xu, Jun-Mei
Xu, Hui-Xiong
Liu, Chang
Bo, Xiao-Wan
Li, Xiao-Long
Guo, Le-Hang
Liu, Bo-Ji
Liu, Lin-Na
Xu, Xiao-Hong
author_sort Zhang, Yi-Feng
collection PubMed
description To investigate the diagnostic performance of combined use of conventional ultrasound (US) and elastography, including conventional strain elastography such as elasticity imaging (EI) and acoustic radiation force impulse (ARFI) elastography, and to evaluate their usefulness in recommending fine-needle aspiration (FNA). A total of 556 pathologically proven thyroid nodules were evaluated by US, EI, and ARFI examinations in this study. Three blinded readers scored the likelihood of malignancy for 4 datasets (ie, US alone, US and EI, US and virtual touch tissue imaging [VTI], and US and virtual touch tissue quantification [VTQ]). The diagnostic performances of 4 datasets in differentiating malignant from benign thyroid nodules were evaluated. The decision-making changes for FNA recommendation in the indeterminate nodules or the probably benign nodules on conventional US were evaluated after review of elastography. The diagnostic performance in terms of area under the ROC curve did not show any change after adding EI, VTI, or VTQ for analysis; and no differences were found among different readers; however, the specificity and positive predictive value (PPV) improved significantly after adding VTI or VTQ for analysis in the senior reader. For the indeterminate nodules on US that were pathologically benign, VTQ made correct decision-making changes from FNA biopsy to follow-up in a mean of 82.6% nodules, which was significantly higher than those achieved by EI (46.8%) and VTI (54.4%) (both P < 0.05). With regard to the probably benign nodules on US that were pathologically malignant, EI made the highest correct decision-making change from follow-up to FNA biopsy in a mean of 62.6% nodules (compared with 41.5% on VTQ, P < 0.05). The results indicated that ARFI increases the specificity and PPV in diagnosing thyroid nodules. US combined VTQ might be helpful in reducing unnecessary FNA for indeterminate nodules on US whereas US combined EI is useful to detect the false negative nodules that are probably benign on conventional US.
format Online
Article
Text
id pubmed-4620786
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-46207862015-10-27 Acoustic Radiation Force Impulse Elastography: A Useful Tool for Differential Diagnosis of Thyroid Nodules and Recommending Fine-Needle Aspiration: A Diagnostic Accuracy Study Zhang, Yi-Feng Xu, Jun-Mei Xu, Hui-Xiong Liu, Chang Bo, Xiao-Wan Li, Xiao-Long Guo, Le-Hang Liu, Bo-Ji Liu, Lin-Na Xu, Xiao-Hong Medicine (Baltimore) 6800 To investigate the diagnostic performance of combined use of conventional ultrasound (US) and elastography, including conventional strain elastography such as elasticity imaging (EI) and acoustic radiation force impulse (ARFI) elastography, and to evaluate their usefulness in recommending fine-needle aspiration (FNA). A total of 556 pathologically proven thyroid nodules were evaluated by US, EI, and ARFI examinations in this study. Three blinded readers scored the likelihood of malignancy for 4 datasets (ie, US alone, US and EI, US and virtual touch tissue imaging [VTI], and US and virtual touch tissue quantification [VTQ]). The diagnostic performances of 4 datasets in differentiating malignant from benign thyroid nodules were evaluated. The decision-making changes for FNA recommendation in the indeterminate nodules or the probably benign nodules on conventional US were evaluated after review of elastography. The diagnostic performance in terms of area under the ROC curve did not show any change after adding EI, VTI, or VTQ for analysis; and no differences were found among different readers; however, the specificity and positive predictive value (PPV) improved significantly after adding VTI or VTQ for analysis in the senior reader. For the indeterminate nodules on US that were pathologically benign, VTQ made correct decision-making changes from FNA biopsy to follow-up in a mean of 82.6% nodules, which was significantly higher than those achieved by EI (46.8%) and VTI (54.4%) (both P < 0.05). With regard to the probably benign nodules on US that were pathologically malignant, EI made the highest correct decision-making change from follow-up to FNA biopsy in a mean of 62.6% nodules (compared with 41.5% on VTQ, P < 0.05). The results indicated that ARFI increases the specificity and PPV in diagnosing thyroid nodules. US combined VTQ might be helpful in reducing unnecessary FNA for indeterminate nodules on US whereas US combined EI is useful to detect the false negative nodules that are probably benign on conventional US. Wolters Kluwer Health 2015-10-23 /pmc/articles/PMC4620786/ /pubmed/26496325 http://dx.doi.org/10.1097/MD.0000000000001834 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0, where it is permissible to download, share and reproduce the work in any medium, provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle 6800
Zhang, Yi-Feng
Xu, Jun-Mei
Xu, Hui-Xiong
Liu, Chang
Bo, Xiao-Wan
Li, Xiao-Long
Guo, Le-Hang
Liu, Bo-Ji
Liu, Lin-Na
Xu, Xiao-Hong
Acoustic Radiation Force Impulse Elastography: A Useful Tool for Differential Diagnosis of Thyroid Nodules and Recommending Fine-Needle Aspiration: A Diagnostic Accuracy Study
title Acoustic Radiation Force Impulse Elastography: A Useful Tool for Differential Diagnosis of Thyroid Nodules and Recommending Fine-Needle Aspiration: A Diagnostic Accuracy Study
title_full Acoustic Radiation Force Impulse Elastography: A Useful Tool for Differential Diagnosis of Thyroid Nodules and Recommending Fine-Needle Aspiration: A Diagnostic Accuracy Study
title_fullStr Acoustic Radiation Force Impulse Elastography: A Useful Tool for Differential Diagnosis of Thyroid Nodules and Recommending Fine-Needle Aspiration: A Diagnostic Accuracy Study
title_full_unstemmed Acoustic Radiation Force Impulse Elastography: A Useful Tool for Differential Diagnosis of Thyroid Nodules and Recommending Fine-Needle Aspiration: A Diagnostic Accuracy Study
title_short Acoustic Radiation Force Impulse Elastography: A Useful Tool for Differential Diagnosis of Thyroid Nodules and Recommending Fine-Needle Aspiration: A Diagnostic Accuracy Study
title_sort acoustic radiation force impulse elastography: a useful tool for differential diagnosis of thyroid nodules and recommending fine-needle aspiration: a diagnostic accuracy study
topic 6800
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4620786/
https://www.ncbi.nlm.nih.gov/pubmed/26496325
http://dx.doi.org/10.1097/MD.0000000000001834
work_keys_str_mv AT zhangyifeng acousticradiationforceimpulseelastographyausefultoolfordifferentialdiagnosisofthyroidnodulesandrecommendingfineneedleaspirationadiagnosticaccuracystudy
AT xujunmei acousticradiationforceimpulseelastographyausefultoolfordifferentialdiagnosisofthyroidnodulesandrecommendingfineneedleaspirationadiagnosticaccuracystudy
AT xuhuixiong acousticradiationforceimpulseelastographyausefultoolfordifferentialdiagnosisofthyroidnodulesandrecommendingfineneedleaspirationadiagnosticaccuracystudy
AT liuchang acousticradiationforceimpulseelastographyausefultoolfordifferentialdiagnosisofthyroidnodulesandrecommendingfineneedleaspirationadiagnosticaccuracystudy
AT boxiaowan acousticradiationforceimpulseelastographyausefultoolfordifferentialdiagnosisofthyroidnodulesandrecommendingfineneedleaspirationadiagnosticaccuracystudy
AT lixiaolong acousticradiationforceimpulseelastographyausefultoolfordifferentialdiagnosisofthyroidnodulesandrecommendingfineneedleaspirationadiagnosticaccuracystudy
AT guolehang acousticradiationforceimpulseelastographyausefultoolfordifferentialdiagnosisofthyroidnodulesandrecommendingfineneedleaspirationadiagnosticaccuracystudy
AT liuboji acousticradiationforceimpulseelastographyausefultoolfordifferentialdiagnosisofthyroidnodulesandrecommendingfineneedleaspirationadiagnosticaccuracystudy
AT liulinna acousticradiationforceimpulseelastographyausefultoolfordifferentialdiagnosisofthyroidnodulesandrecommendingfineneedleaspirationadiagnosticaccuracystudy
AT xuxiaohong acousticradiationforceimpulseelastographyausefultoolfordifferentialdiagnosisofthyroidnodulesandrecommendingfineneedleaspirationadiagnosticaccuracystudy