Cargando…
Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome?
OBJECTIVES: To determine whether the mean platelet volume (MPV) and MPV/platelet (PLT) values can be used in the study of sepsis and systemic inflammatory response syndrome (SIRS). METHODS: In this retrospective case-controlled study, 69 sepsis, 69 SIRS patients, and 72 control group who were treate...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Saudi Medical Journal
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4621724/ https://www.ncbi.nlm.nih.gov/pubmed/26446329 http://dx.doi.org/10.15537/smj.2015.10.10718 |
_version_ | 1782397488049684480 |
---|---|
author | Ates, Selma Oksuz, Hafıze Dogu, Bırsen Bozkus, Fulsen Ucmak, Hasan Yanıt, Fadime |
author_facet | Ates, Selma Oksuz, Hafıze Dogu, Bırsen Bozkus, Fulsen Ucmak, Hasan Yanıt, Fadime |
author_sort | Ates, Selma |
collection | PubMed |
description | OBJECTIVES: To determine whether the mean platelet volume (MPV) and MPV/platelet (PLT) values can be used in the study of sepsis and systemic inflammatory response syndrome (SIRS). METHODS: In this retrospective case-controlled study, 69 sepsis, 69 SIRS patients, and 72 control group who were treated in the years 2012-2013 were reviewed, and both the MPV and MPV/PLT rates were evaluated in all groups at Kahramanmaras Sutcu Imam University Intensive Care Unit, Kahramanmaras, Turkey. RESULTS: Statistically significant difference was found between sepsis, SIRS, and control groups when comparing the MPV and MPV/PLT ratio (p<0.05), and no significant difference was found between sepsis and SIRS groups in terms of MPV and MPV/PLT ratio (p>0.05). Mean platelet volume values for sepsis and control groups was 10.07/8.731 femtoliter (fL) (p=0.000), and 9.45/8.731 fL (p=0.000) for SIRS and control groups. In the group of sepsis patients, the MPV was found to be at cut-off 8.915, sensitivity 71%, and specificity 63.9%. In the group of patients with SIRS, MPV was found to be at cut-off 8.85, sensitivity 69.6%, and specificity 62.5%. For the MPV/PLT values, the specificity and sensitivity were found to be insignificant. CONCLUSION: This study shows that although there was no significant reduction in the PLT values between the sepsis and SIRS patients, the MPV and MPV/PLT ratio values were found to have significant differences. However, the specificity and sensitivity of the values were not reliable standard to be used as a test. |
format | Online Article Text |
id | pubmed-4621724 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Saudi Medical Journal |
record_format | MEDLINE/PubMed |
spelling | pubmed-46217242015-10-30 Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome? Ates, Selma Oksuz, Hafıze Dogu, Bırsen Bozkus, Fulsen Ucmak, Hasan Yanıt, Fadime Saudi Med J Original Article OBJECTIVES: To determine whether the mean platelet volume (MPV) and MPV/platelet (PLT) values can be used in the study of sepsis and systemic inflammatory response syndrome (SIRS). METHODS: In this retrospective case-controlled study, 69 sepsis, 69 SIRS patients, and 72 control group who were treated in the years 2012-2013 were reviewed, and both the MPV and MPV/PLT rates were evaluated in all groups at Kahramanmaras Sutcu Imam University Intensive Care Unit, Kahramanmaras, Turkey. RESULTS: Statistically significant difference was found between sepsis, SIRS, and control groups when comparing the MPV and MPV/PLT ratio (p<0.05), and no significant difference was found between sepsis and SIRS groups in terms of MPV and MPV/PLT ratio (p>0.05). Mean platelet volume values for sepsis and control groups was 10.07/8.731 femtoliter (fL) (p=0.000), and 9.45/8.731 fL (p=0.000) for SIRS and control groups. In the group of sepsis patients, the MPV was found to be at cut-off 8.915, sensitivity 71%, and specificity 63.9%. In the group of patients with SIRS, MPV was found to be at cut-off 8.85, sensitivity 69.6%, and specificity 62.5%. For the MPV/PLT values, the specificity and sensitivity were found to be insignificant. CONCLUSION: This study shows that although there was no significant reduction in the PLT values between the sepsis and SIRS patients, the MPV and MPV/PLT ratio values were found to have significant differences. However, the specificity and sensitivity of the values were not reliable standard to be used as a test. Saudi Medical Journal 2015-10 /pmc/articles/PMC4621724/ /pubmed/26446329 http://dx.doi.org/10.15537/smj.2015.10.10718 Text en Copyright: © Saudi Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Ates, Selma Oksuz, Hafıze Dogu, Bırsen Bozkus, Fulsen Ucmak, Hasan Yanıt, Fadime Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome? |
title | Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome? |
title_full | Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome? |
title_fullStr | Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome? |
title_full_unstemmed | Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome? |
title_short | Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome? |
title_sort | can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome? |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4621724/ https://www.ncbi.nlm.nih.gov/pubmed/26446329 http://dx.doi.org/10.15537/smj.2015.10.10718 |
work_keys_str_mv | AT atesselma canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome AT oksuzhafıze canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome AT dogubırsen canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome AT bozkusfulsen canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome AT ucmakhasan canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome AT yanıtfadime canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome |