Cargando…

Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome?

OBJECTIVES: To determine whether the mean platelet volume (MPV) and MPV/platelet (PLT) values can be used in the study of sepsis and systemic inflammatory response syndrome (SIRS). METHODS: In this retrospective case-controlled study, 69 sepsis, 69 SIRS patients, and 72 control group who were treate...

Descripción completa

Detalles Bibliográficos
Autores principales: Ates, Selma, Oksuz, Hafıze, Dogu, Bırsen, Bozkus, Fulsen, Ucmak, Hasan, Yanıt, Fadime
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Saudi Medical Journal 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4621724/
https://www.ncbi.nlm.nih.gov/pubmed/26446329
http://dx.doi.org/10.15537/smj.2015.10.10718
_version_ 1782397488049684480
author Ates, Selma
Oksuz, Hafıze
Dogu, Bırsen
Bozkus, Fulsen
Ucmak, Hasan
Yanıt, Fadime
author_facet Ates, Selma
Oksuz, Hafıze
Dogu, Bırsen
Bozkus, Fulsen
Ucmak, Hasan
Yanıt, Fadime
author_sort Ates, Selma
collection PubMed
description OBJECTIVES: To determine whether the mean platelet volume (MPV) and MPV/platelet (PLT) values can be used in the study of sepsis and systemic inflammatory response syndrome (SIRS). METHODS: In this retrospective case-controlled study, 69 sepsis, 69 SIRS patients, and 72 control group who were treated in the years 2012-2013 were reviewed, and both the MPV and MPV/PLT rates were evaluated in all groups at Kahramanmaras Sutcu Imam University Intensive Care Unit, Kahramanmaras, Turkey. RESULTS: Statistically significant difference was found between sepsis, SIRS, and control groups when comparing the MPV and MPV/PLT ratio (p<0.05), and no significant difference was found between sepsis and SIRS groups in terms of MPV and MPV/PLT ratio (p>0.05). Mean platelet volume values for sepsis and control groups was 10.07/8.731 femtoliter (fL) (p=0.000), and 9.45/8.731 fL (p=0.000) for SIRS and control groups. In the group of sepsis patients, the MPV was found to be at cut-off 8.915, sensitivity 71%, and specificity 63.9%. In the group of patients with SIRS, MPV was found to be at cut-off 8.85, sensitivity 69.6%, and specificity 62.5%. For the MPV/PLT values, the specificity and sensitivity were found to be insignificant. CONCLUSION: This study shows that although there was no significant reduction in the PLT values between the sepsis and SIRS patients, the MPV and MPV/PLT ratio values were found to have significant differences. However, the specificity and sensitivity of the values were not reliable standard to be used as a test.
format Online
Article
Text
id pubmed-4621724
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Saudi Medical Journal
record_format MEDLINE/PubMed
spelling pubmed-46217242015-10-30 Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome? Ates, Selma Oksuz, Hafıze Dogu, Bırsen Bozkus, Fulsen Ucmak, Hasan Yanıt, Fadime Saudi Med J Original Article OBJECTIVES: To determine whether the mean platelet volume (MPV) and MPV/platelet (PLT) values can be used in the study of sepsis and systemic inflammatory response syndrome (SIRS). METHODS: In this retrospective case-controlled study, 69 sepsis, 69 SIRS patients, and 72 control group who were treated in the years 2012-2013 were reviewed, and both the MPV and MPV/PLT rates were evaluated in all groups at Kahramanmaras Sutcu Imam University Intensive Care Unit, Kahramanmaras, Turkey. RESULTS: Statistically significant difference was found between sepsis, SIRS, and control groups when comparing the MPV and MPV/PLT ratio (p<0.05), and no significant difference was found between sepsis and SIRS groups in terms of MPV and MPV/PLT ratio (p>0.05). Mean platelet volume values for sepsis and control groups was 10.07/8.731 femtoliter (fL) (p=0.000), and 9.45/8.731 fL (p=0.000) for SIRS and control groups. In the group of sepsis patients, the MPV was found to be at cut-off 8.915, sensitivity 71%, and specificity 63.9%. In the group of patients with SIRS, MPV was found to be at cut-off 8.85, sensitivity 69.6%, and specificity 62.5%. For the MPV/PLT values, the specificity and sensitivity were found to be insignificant. CONCLUSION: This study shows that although there was no significant reduction in the PLT values between the sepsis and SIRS patients, the MPV and MPV/PLT ratio values were found to have significant differences. However, the specificity and sensitivity of the values were not reliable standard to be used as a test. Saudi Medical Journal 2015-10 /pmc/articles/PMC4621724/ /pubmed/26446329 http://dx.doi.org/10.15537/smj.2015.10.10718 Text en Copyright: © Saudi Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Ates, Selma
Oksuz, Hafıze
Dogu, Bırsen
Bozkus, Fulsen
Ucmak, Hasan
Yanıt, Fadime
Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome?
title Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome?
title_full Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome?
title_fullStr Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome?
title_full_unstemmed Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome?
title_short Can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome?
title_sort can mean platelet volume and mean platelet volume/platelet count ratio be used as a diagnostic marker for sepsis and systemic inflammatory response syndrome?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4621724/
https://www.ncbi.nlm.nih.gov/pubmed/26446329
http://dx.doi.org/10.15537/smj.2015.10.10718
work_keys_str_mv AT atesselma canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome
AT oksuzhafıze canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome
AT dogubırsen canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome
AT bozkusfulsen canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome
AT ucmakhasan canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome
AT yanıtfadime canmeanplateletvolumeandmeanplateletvolumeplateletcountratiobeusedasadiagnosticmarkerforsepsisandsystemicinflammatoryresponsesyndrome