INTRODUCTION: Glycosylated hemoglobin (HbA1c) concentrations measured in clinical chemistry laboratories show large differences between their interlaboratory reported values. Laboratory measurements of quality performance should be based on quantitative data. The sigma metrics model provides an obje...

Descripción completa

Detalles Bibliográficos
Autores principales: Huysal, Kağan, Budak, Yasemin U
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4622199/
https://www.ncbi.nlm.nih.gov/pubmed/26527591
http://dx.doi.org/10.11613/BM.2015.042
_version_ 1782397560172838912
author Huysal, Kağan
Budak, Yasemin U
author_facet Huysal, Kağan
Budak, Yasemin U
author_sort Huysal, Kağan
collection PubMed
description INTRODUCTION: Glycosylated hemoglobin (HbA1c) concentrations measured in clinical chemistry laboratories show large differences between their interlaboratory reported values. Laboratory measurements of quality performance should be based on quantitative data. The sigma metrics model provides an objective method for the assessment of current HbA1c assays and is useful in quality management planning. The aim of our study was to evaluate the analytical performance of the MQ-2000 PT HbA1c analyzer test results in the context of our operating conditions on the sigma scale. MATERIALS AND METHODS: The coefficient of variation was determined from the calculated mean and standard deviation evaluated from internal quality control (QC) (N = 168 days) (Shanghai Huachen Biological Reagent Co. Ltd, China) data, and records of external quality data (KBUDEK, İstanbul, Turkey) measured in the period from May to November 2013 were used to determine the bias. The resulting data and total allowable error rate (TEA = 10%) from the Clinical Laboratory Improvement Amendments of 1988 (CLIA’88) were used to calculate the sigma level. RESULTS: The calculated coefficient of variations (CVs) at the two levels, normal (QC1 = 36.6 ± 2.38 mmol/mol) and pathological (QC2 = 84.7 ± 2.68 mmol/mol), were 6.5% and 3.1%, respectively. The average bias between the external QC and MQ-2000 PT during the study period was 4.3%. The calculated average sigma value was 1.19. CONCLUSIONS: The MQ-2000 PT HbA1c is a new analyser in the market; there is need for improvement and the method should be controlled with greater attention to ensure quality.
format Online
Article
Text
id pubmed-4622199
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Croatian Society of Medical Biochemistry and Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-46221992015-10-30 Application of sigma metrics for the assessment of quality assurance using the MQ-2000 PT HbA1c analyzer Huysal, Kağan Budak, Yasemin U Biochem Med (Zagreb) Research Article INTRODUCTION: Glycosylated hemoglobin (HbA1c) concentrations measured in clinical chemistry laboratories show large differences between their interlaboratory reported values. Laboratory measurements of quality performance should be based on quantitative data. The sigma metrics model provides an objective method for the assessment of current HbA1c assays and is useful in quality management planning. The aim of our study was to evaluate the analytical performance of the MQ-2000 PT HbA1c analyzer test results in the context of our operating conditions on the sigma scale. MATERIALS AND METHODS: The coefficient of variation was determined from the calculated mean and standard deviation evaluated from internal quality control (QC) (N = 168 days) (Shanghai Huachen Biological Reagent Co. Ltd, China) data, and records of external quality data (KBUDEK, İstanbul, Turkey) measured in the period from May to November 2013 were used to determine the bias. The resulting data and total allowable error rate (TEA = 10%) from the Clinical Laboratory Improvement Amendments of 1988 (CLIA’88) were used to calculate the sigma level. RESULTS: The calculated coefficient of variations (CVs) at the two levels, normal (QC1 = 36.6 ± 2.38 mmol/mol) and pathological (QC2 = 84.7 ± 2.68 mmol/mol), were 6.5% and 3.1%, respectively. The average bias between the external QC and MQ-2000 PT during the study period was 4.3%. The calculated average sigma value was 1.19. CONCLUSIONS: The MQ-2000 PT HbA1c is a new analyser in the market; there is need for improvement and the method should be controlled with greater attention to ensure quality. Croatian Society of Medical Biochemistry and Laboratory Medicine 2015-10-15 /pmc/articles/PMC4622199/ /pubmed/26527591 http://dx.doi.org/10.11613/BM.2015.042 Text en
spellingShingle Research Article
Huysal, Kağan
Budak, Yasemin U
Application of sigma metrics for the assessment of quality assurance using the MQ-2000 PT HbA1c analyzer
title Application of sigma metrics for the assessment of quality assurance using the MQ-2000 PT HbA1c analyzer
title_full Application of sigma metrics for the assessment of quality assurance using the MQ-2000 PT HbA1c analyzer
title_fullStr Application of sigma metrics for the assessment of quality assurance using the MQ-2000 PT HbA1c analyzer
title_full_unstemmed Application of sigma metrics for the assessment of quality assurance using the MQ-2000 PT HbA1c analyzer
title_short Application of sigma metrics for the assessment of quality assurance using the MQ-2000 PT HbA1c analyzer
title_sort application of sigma metrics for the assessment of quality assurance using the mq-2000 pt hba1c analyzer
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4622199/
https://www.ncbi.nlm.nih.gov/pubmed/26527591
http://dx.doi.org/10.11613/BM.2015.042
work_keys_str_mv AT huysalkagan applicationofsigmametricsfortheassessmentofqualityassuranceusingthemq2000pthba1canalyzer
AT budakyaseminu applicationofsigmametricsfortheassessmentofqualityassuranceusingthemq2000pthba1canalyzer