Cargando…

Efficacy and Safety of Hair Removal with a Long-Pulsed Diode Laser Depending on the Spot Size: A Randomized, Evaluators-Blinded, Left-Right Study

BACKGROUND: The efficacy of the long-pulsed diode laser (LPDL) in hair removal is determined with various physical parameters. Recently, LPDLs with a larger spot size are commercially available; however, the independent effect of spot size on hair removal has not been studied. OBJECTIVE: This study...

Descripción completa

Detalles Bibliográficos
Autores principales: Jo, Seong Jin, Kim, Jin Yong, Ban, Juhee, Lee, Youngjoo, Kwon, Ohsang, Koh, Wooseok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Dermatological Association; The Korean Society for Investigative Dermatology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4622885/
https://www.ncbi.nlm.nih.gov/pubmed/26512165
http://dx.doi.org/10.5021/ad.2015.27.5.517
Descripción
Sumario:BACKGROUND: The efficacy of the long-pulsed diode laser (LPDL) in hair removal is determined with various physical parameters. Recently, LPDLs with a larger spot size are commercially available; however, the independent effect of spot size on hair removal has not been studied. OBJECTIVE: This study aimed to compare the efficacy of the LPDL in hair removal depending on the spot size. METHODS: A randomized, evaluators-blind, intrapatient comparison (left vs. right) trial was designed. Ten healthy Korean women received three hair removal treatment sessions on both armpits with the 805-nm LPDL and followed for 3 months. A 10×10 mm handpiece (D1) or a 10×30 mm handpiece (D3) was randomly assigned to the right or left axilla. The fluence, pulse duration, and epidermal cooling temperature were identical for both armpits. Hair clearance was quantified with high-resolution photos taken at each visit. Postprocedural pain was quantified on a visual analogue scale. Adverse events were evaluated by physical examination and the patients' self-report. RESULTS: The mean hair clearance at 3 months after three treatment sessions was 38.7% and 50.1% on the armpits treated with D1 and D3, respectively (p=0.028). Procedural pain was significantly greater in the side treated with D3 (p=0.009). Serious adverse events were not observed. CONCLUSION: Given that the pulse duration, fluence, and epidermal cooling were identical, the 805-nm LPDL at the three times larger spot size showed an efficacy improvement of 29.5% in axillary hair removal without serious adverse events.