Cargando…

Efficacy and Safety of Hair Removal with a Long-Pulsed Diode Laser Depending on the Spot Size: A Randomized, Evaluators-Blinded, Left-Right Study

BACKGROUND: The efficacy of the long-pulsed diode laser (LPDL) in hair removal is determined with various physical parameters. Recently, LPDLs with a larger spot size are commercially available; however, the independent effect of spot size on hair removal has not been studied. OBJECTIVE: This study...

Descripción completa

Detalles Bibliográficos
Autores principales: Jo, Seong Jin, Kim, Jin Yong, Ban, Juhee, Lee, Youngjoo, Kwon, Ohsang, Koh, Wooseok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Dermatological Association; The Korean Society for Investigative Dermatology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4622885/
https://www.ncbi.nlm.nih.gov/pubmed/26512165
http://dx.doi.org/10.5021/ad.2015.27.5.517
_version_ 1782397621205204992
author Jo, Seong Jin
Kim, Jin Yong
Ban, Juhee
Lee, Youngjoo
Kwon, Ohsang
Koh, Wooseok
author_facet Jo, Seong Jin
Kim, Jin Yong
Ban, Juhee
Lee, Youngjoo
Kwon, Ohsang
Koh, Wooseok
author_sort Jo, Seong Jin
collection PubMed
description BACKGROUND: The efficacy of the long-pulsed diode laser (LPDL) in hair removal is determined with various physical parameters. Recently, LPDLs with a larger spot size are commercially available; however, the independent effect of spot size on hair removal has not been studied. OBJECTIVE: This study aimed to compare the efficacy of the LPDL in hair removal depending on the spot size. METHODS: A randomized, evaluators-blind, intrapatient comparison (left vs. right) trial was designed. Ten healthy Korean women received three hair removal treatment sessions on both armpits with the 805-nm LPDL and followed for 3 months. A 10×10 mm handpiece (D1) or a 10×30 mm handpiece (D3) was randomly assigned to the right or left axilla. The fluence, pulse duration, and epidermal cooling temperature were identical for both armpits. Hair clearance was quantified with high-resolution photos taken at each visit. Postprocedural pain was quantified on a visual analogue scale. Adverse events were evaluated by physical examination and the patients' self-report. RESULTS: The mean hair clearance at 3 months after three treatment sessions was 38.7% and 50.1% on the armpits treated with D1 and D3, respectively (p=0.028). Procedural pain was significantly greater in the side treated with D3 (p=0.009). Serious adverse events were not observed. CONCLUSION: Given that the pulse duration, fluence, and epidermal cooling were identical, the 805-nm LPDL at the three times larger spot size showed an efficacy improvement of 29.5% in axillary hair removal without serious adverse events.
format Online
Article
Text
id pubmed-4622885
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Korean Dermatological Association; The Korean Society for Investigative Dermatology
record_format MEDLINE/PubMed
spelling pubmed-46228852015-10-28 Efficacy and Safety of Hair Removal with a Long-Pulsed Diode Laser Depending on the Spot Size: A Randomized, Evaluators-Blinded, Left-Right Study Jo, Seong Jin Kim, Jin Yong Ban, Juhee Lee, Youngjoo Kwon, Ohsang Koh, Wooseok Ann Dermatol Original Article BACKGROUND: The efficacy of the long-pulsed diode laser (LPDL) in hair removal is determined with various physical parameters. Recently, LPDLs with a larger spot size are commercially available; however, the independent effect of spot size on hair removal has not been studied. OBJECTIVE: This study aimed to compare the efficacy of the LPDL in hair removal depending on the spot size. METHODS: A randomized, evaluators-blind, intrapatient comparison (left vs. right) trial was designed. Ten healthy Korean women received three hair removal treatment sessions on both armpits with the 805-nm LPDL and followed for 3 months. A 10×10 mm handpiece (D1) or a 10×30 mm handpiece (D3) was randomly assigned to the right or left axilla. The fluence, pulse duration, and epidermal cooling temperature were identical for both armpits. Hair clearance was quantified with high-resolution photos taken at each visit. Postprocedural pain was quantified on a visual analogue scale. Adverse events were evaluated by physical examination and the patients' self-report. RESULTS: The mean hair clearance at 3 months after three treatment sessions was 38.7% and 50.1% on the armpits treated with D1 and D3, respectively (p=0.028). Procedural pain was significantly greater in the side treated with D3 (p=0.009). Serious adverse events were not observed. CONCLUSION: Given that the pulse duration, fluence, and epidermal cooling were identical, the 805-nm LPDL at the three times larger spot size showed an efficacy improvement of 29.5% in axillary hair removal without serious adverse events. Korean Dermatological Association; The Korean Society for Investigative Dermatology 2015-10 2015-10-02 /pmc/articles/PMC4622885/ /pubmed/26512165 http://dx.doi.org/10.5021/ad.2015.27.5.517 Text en Copyright © 2015 The Korean Dermatological Association and The Korean Society for Investigative Dermatology http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jo, Seong Jin
Kim, Jin Yong
Ban, Juhee
Lee, Youngjoo
Kwon, Ohsang
Koh, Wooseok
Efficacy and Safety of Hair Removal with a Long-Pulsed Diode Laser Depending on the Spot Size: A Randomized, Evaluators-Blinded, Left-Right Study
title Efficacy and Safety of Hair Removal with a Long-Pulsed Diode Laser Depending on the Spot Size: A Randomized, Evaluators-Blinded, Left-Right Study
title_full Efficacy and Safety of Hair Removal with a Long-Pulsed Diode Laser Depending on the Spot Size: A Randomized, Evaluators-Blinded, Left-Right Study
title_fullStr Efficacy and Safety of Hair Removal with a Long-Pulsed Diode Laser Depending on the Spot Size: A Randomized, Evaluators-Blinded, Left-Right Study
title_full_unstemmed Efficacy and Safety of Hair Removal with a Long-Pulsed Diode Laser Depending on the Spot Size: A Randomized, Evaluators-Blinded, Left-Right Study
title_short Efficacy and Safety of Hair Removal with a Long-Pulsed Diode Laser Depending on the Spot Size: A Randomized, Evaluators-Blinded, Left-Right Study
title_sort efficacy and safety of hair removal with a long-pulsed diode laser depending on the spot size: a randomized, evaluators-blinded, left-right study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4622885/
https://www.ncbi.nlm.nih.gov/pubmed/26512165
http://dx.doi.org/10.5021/ad.2015.27.5.517
work_keys_str_mv AT joseongjin efficacyandsafetyofhairremovalwithalongpulseddiodelaserdependingonthespotsizearandomizedevaluatorsblindedleftrightstudy
AT kimjinyong efficacyandsafetyofhairremovalwithalongpulseddiodelaserdependingonthespotsizearandomizedevaluatorsblindedleftrightstudy
AT banjuhee efficacyandsafetyofhairremovalwithalongpulseddiodelaserdependingonthespotsizearandomizedevaluatorsblindedleftrightstudy
AT leeyoungjoo efficacyandsafetyofhairremovalwithalongpulseddiodelaserdependingonthespotsizearandomizedevaluatorsblindedleftrightstudy
AT kwonohsang efficacyandsafetyofhairremovalwithalongpulseddiodelaserdependingonthespotsizearandomizedevaluatorsblindedleftrightstudy
AT kohwooseok efficacyandsafetyofhairremovalwithalongpulseddiodelaserdependingonthespotsizearandomizedevaluatorsblindedleftrightstudy