Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients
INTRODUCTION: Apical protrusion in the central 4-mm ring in the Scheimflug imaging (Pentacam), both for the anterior and posterior floats as well as Corneal Hysteresis and Corneal Resistance Factor by Ocular Response Analyzer (ORA), generally are considered important predictors for post-Lasik ectasi...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Electronic physician
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4623802/ https://www.ncbi.nlm.nih.gov/pubmed/26516449 http://dx.doi.org/10.14661/1394 |
_version_ | 1782397743906422784 |
---|---|
author | Refai, Tamer Adel |
author_facet | Refai, Tamer Adel |
author_sort | Refai, Tamer Adel |
collection | PubMed |
description | INTRODUCTION: Apical protrusion in the central 4-mm ring in the Scheimflug imaging (Pentacam), both for the anterior and posterior floats as well as Corneal Hysteresis and Corneal Resistance Factor by Ocular Response Analyzer (ORA), generally are considered important predictors for post-Lasik ectasia. The aim of this work was to find out if there is a statistically significant correlation between these different predictors and their correlation with the central corneal thickness for refractive non-keratoconic Egyptian patients trying to achieve a better decision and avoiding ectasia. METHODS: This case-control study involved 142 eyes (of 77 patients with various refractive errors) arriving at the refractive surgery unit in the Research Institute of Ophthalmology in Giza (Egypt) in 2014–2015 seeking excimer laser ablation. The flattest, steepest keratometry readings, central corneal thickness as well as the apical protrusion in the central 4-mm ring, both for the anterior and posterior floats, in microns were measured by Scheimflug imaging. The Corneal Hysteresis and Corneal Resistance Factor were measured by the ocular response analyzer. Statistical analysis was performed by SPSS, using the Pearson correlation test. RESULTS: The spherical refractive error ranged from +7.00 to −13.00 diopters (−3.80 ± 2.89). The central pachymetry ranged from 494 to 634 μm (550.35 ± 32.13). For the central 4-mm ring, the apical protrusion ranged from 0 to +15 μ (6.93 ± 2.99) for the anterior float and from −3 to +20 μ (9.33 ± 4.55) for the posterior float. The Corneal Hysterisis (CH) ranged from 7 to 14.8 mmHg (10.18±1.44), while the Corneal Resistance Factor (CRF) ranged from 7.5 to 14.9 mmHg (10.58 ± 1.67). There was a strong positive correlation between the central corneal thickness and both Corneal Hysteresis (CH: r = 0.56, P ≤ 0.01) and Corneal Resistance Factor (r = 0.46, P ≤ 0.01). A significant correlation (P < 0.05, r = 0.15) existed between apical protrusion in the posterior float and the central corneal thickness. Also, significant negative correlation (P < 0.05, r = −0.12) existed between apical protrusion in the anterior float by pentacam and the Corneal Resistance Factor by ocular response analyzer. CONCLUSIONS: Our finding of a strong positive correlation between both Corneal Hysteresis and Corneal Resistance Factor and the Central corneal thickness being important for biomechanical corneal stability. The findings of this study also support using both machines preoperatively to decrease the risk of post-Lasik ectasia. |
format | Online Article Text |
id | pubmed-4623802 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Electronic physician |
record_format | MEDLINE/PubMed |
spelling | pubmed-46238022015-10-29 Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients Refai, Tamer Adel Electron Physician Original Article INTRODUCTION: Apical protrusion in the central 4-mm ring in the Scheimflug imaging (Pentacam), both for the anterior and posterior floats as well as Corneal Hysteresis and Corneal Resistance Factor by Ocular Response Analyzer (ORA), generally are considered important predictors for post-Lasik ectasia. The aim of this work was to find out if there is a statistically significant correlation between these different predictors and their correlation with the central corneal thickness for refractive non-keratoconic Egyptian patients trying to achieve a better decision and avoiding ectasia. METHODS: This case-control study involved 142 eyes (of 77 patients with various refractive errors) arriving at the refractive surgery unit in the Research Institute of Ophthalmology in Giza (Egypt) in 2014–2015 seeking excimer laser ablation. The flattest, steepest keratometry readings, central corneal thickness as well as the apical protrusion in the central 4-mm ring, both for the anterior and posterior floats, in microns were measured by Scheimflug imaging. The Corneal Hysteresis and Corneal Resistance Factor were measured by the ocular response analyzer. Statistical analysis was performed by SPSS, using the Pearson correlation test. RESULTS: The spherical refractive error ranged from +7.00 to −13.00 diopters (−3.80 ± 2.89). The central pachymetry ranged from 494 to 634 μm (550.35 ± 32.13). For the central 4-mm ring, the apical protrusion ranged from 0 to +15 μ (6.93 ± 2.99) for the anterior float and from −3 to +20 μ (9.33 ± 4.55) for the posterior float. The Corneal Hysterisis (CH) ranged from 7 to 14.8 mmHg (10.18±1.44), while the Corneal Resistance Factor (CRF) ranged from 7.5 to 14.9 mmHg (10.58 ± 1.67). There was a strong positive correlation between the central corneal thickness and both Corneal Hysteresis (CH: r = 0.56, P ≤ 0.01) and Corneal Resistance Factor (r = 0.46, P ≤ 0.01). A significant correlation (P < 0.05, r = 0.15) existed between apical protrusion in the posterior float and the central corneal thickness. Also, significant negative correlation (P < 0.05, r = −0.12) existed between apical protrusion in the anterior float by pentacam and the Corneal Resistance Factor by ocular response analyzer. CONCLUSIONS: Our finding of a strong positive correlation between both Corneal Hysteresis and Corneal Resistance Factor and the Central corneal thickness being important for biomechanical corneal stability. The findings of this study also support using both machines preoperatively to decrease the risk of post-Lasik ectasia. Electronic physician 2015-10-19 /pmc/articles/PMC4623802/ /pubmed/26516449 http://dx.doi.org/10.14661/1394 Text en © 2015 The Authors This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (http://creativecommons.org/licenses/by-nc-nd/3.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Original Article Refai, Tamer Adel Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients |
title | Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients |
title_full | Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients |
title_fullStr | Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients |
title_full_unstemmed | Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients |
title_short | Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients |
title_sort | correlation between apical protrusion in the scheimflug imaging and corneal hysteresis and corneal resistance factor by ocular response analyzer, among refractive non-keratoconic egyptian patients |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4623802/ https://www.ncbi.nlm.nih.gov/pubmed/26516449 http://dx.doi.org/10.14661/1394 |
work_keys_str_mv | AT refaitameradel correlationbetweenapicalprotrusioninthescheimflugimagingandcornealhysteresisandcornealresistancefactorbyocularresponseanalyzeramongrefractivenonkeratoconicegyptianpatients |