Cargando…

Effect of Preheating and Precooling on the Flexural Strength and Modulus of Elasticity of Nanohybrid and Silorane-based Composite

STATEMENT OF THE PROBLEM: Composite resin may be used in different temperatures; it is crucial to determine the effect of temperature on mechanical properties of nanohybrid and silorane-based composite. PURPOSE: This in vitro study compared the flexural strength and modulus of elasticity of nanohybr...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharafeddin, Farahnaz, Motamedi, Mehran, Fattah, Zahra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4623839/
https://www.ncbi.nlm.nih.gov/pubmed/26535401
_version_ 1782397749313929216
author Sharafeddin, Farahnaz
Motamedi, Mehran
Fattah, Zahra
author_facet Sharafeddin, Farahnaz
Motamedi, Mehran
Fattah, Zahra
author_sort Sharafeddin, Farahnaz
collection PubMed
description STATEMENT OF THE PROBLEM: Composite resin may be used in different temperatures; it is crucial to determine the effect of temperature on mechanical properties of nanohybrid and silorane-based composite. PURPOSE: This in vitro study compared the flexural strength and modulus of elasticity of nanohybrid and silorane-based resin composite, at 4˚C, room temperature (25˚C), and 45˚C. MATERIALS AND METHOD: In this experimental study, 60 specimens were prepared in a metal split mold (2×2×25mm). Two different resin composites, Filtek Z250 XT (3M/ ESPE) and Filtek P90 (3M/ESPE), were evaluated. The material were inserted into split molds at room temperature, 4˚C or 45˚C and cured with LED (1200 mW/cm(2)) for 20 seconds in four points (n=10). Then, a three-point bending test was performed using a universal testing machine at a crosshead speed of 0.5 mm/min for measuring the flexural strength and flexural modulus of samples. The data were analyzed by the two-way ANOVA and Tukey test (p< 0.05). RESULTS: The mean highest flexural strength was observed at 45˚C, showing statistically significant difference with flexural strength at 4˚C (p= 0.0001) and 25˚C (p= 0.003) regardless of the type of resin composite. The flexural modulus at 45˚C was highest, showing the statistically significant difference with flexural modulus at 4˚C (p= 0.0001) and 25˚C (p= 0.002). The flexural modulus was statistically different between nanohybrid and silorane-based resin composite (p= 0.01) in 25˚C and 45˚C, but there were no statistically significant differences between flexural strength of Filtek Z250 XT and Filtek P90 regardless of the temperatures (p= 0.062). CONCLUSION: Preheating the resin composite at 45˚C improves flexural strength and modulus of nanohybrid and silorane-based resin composite. However, flexural strength and modulus of the tested materials were not affected by precooling. The flexural modulus of nanohybrid resin composite was significantly higher than silorane-based resin composite in 25˚C and 45˚C temperatures.
format Online
Article
Text
id pubmed-4623839
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-46238392015-11-03 Effect of Preheating and Precooling on the Flexural Strength and Modulus of Elasticity of Nanohybrid and Silorane-based Composite Sharafeddin, Farahnaz Motamedi, Mehran Fattah, Zahra J Dent (Shiraz) Original Article STATEMENT OF THE PROBLEM: Composite resin may be used in different temperatures; it is crucial to determine the effect of temperature on mechanical properties of nanohybrid and silorane-based composite. PURPOSE: This in vitro study compared the flexural strength and modulus of elasticity of nanohybrid and silorane-based resin composite, at 4˚C, room temperature (25˚C), and 45˚C. MATERIALS AND METHOD: In this experimental study, 60 specimens were prepared in a metal split mold (2×2×25mm). Two different resin composites, Filtek Z250 XT (3M/ ESPE) and Filtek P90 (3M/ESPE), were evaluated. The material were inserted into split molds at room temperature, 4˚C or 45˚C and cured with LED (1200 mW/cm(2)) for 20 seconds in four points (n=10). Then, a three-point bending test was performed using a universal testing machine at a crosshead speed of 0.5 mm/min for measuring the flexural strength and flexural modulus of samples. The data were analyzed by the two-way ANOVA and Tukey test (p< 0.05). RESULTS: The mean highest flexural strength was observed at 45˚C, showing statistically significant difference with flexural strength at 4˚C (p= 0.0001) and 25˚C (p= 0.003) regardless of the type of resin composite. The flexural modulus at 45˚C was highest, showing the statistically significant difference with flexural modulus at 4˚C (p= 0.0001) and 25˚C (p= 0.002). The flexural modulus was statistically different between nanohybrid and silorane-based resin composite (p= 0.01) in 25˚C and 45˚C, but there were no statistically significant differences between flexural strength of Filtek Z250 XT and Filtek P90 regardless of the temperatures (p= 0.062). CONCLUSION: Preheating the resin composite at 45˚C improves flexural strength and modulus of nanohybrid and silorane-based resin composite. However, flexural strength and modulus of the tested materials were not affected by precooling. The flexural modulus of nanohybrid resin composite was significantly higher than silorane-based resin composite in 25˚C and 45˚C temperatures. Shiraz University of Medical Sciences 2015-09 /pmc/articles/PMC4623839/ /pubmed/26535401 Text en © 2015: Journal of dentistry (Shiraz) This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Sharafeddin, Farahnaz
Motamedi, Mehran
Fattah, Zahra
Effect of Preheating and Precooling on the Flexural Strength and Modulus of Elasticity of Nanohybrid and Silorane-based Composite
title Effect of Preheating and Precooling on the Flexural Strength and Modulus of Elasticity of Nanohybrid and Silorane-based Composite
title_full Effect of Preheating and Precooling on the Flexural Strength and Modulus of Elasticity of Nanohybrid and Silorane-based Composite
title_fullStr Effect of Preheating and Precooling on the Flexural Strength and Modulus of Elasticity of Nanohybrid and Silorane-based Composite
title_full_unstemmed Effect of Preheating and Precooling on the Flexural Strength and Modulus of Elasticity of Nanohybrid and Silorane-based Composite
title_short Effect of Preheating and Precooling on the Flexural Strength and Modulus of Elasticity of Nanohybrid and Silorane-based Composite
title_sort effect of preheating and precooling on the flexural strength and modulus of elasticity of nanohybrid and silorane-based composite
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4623839/
https://www.ncbi.nlm.nih.gov/pubmed/26535401
work_keys_str_mv AT sharafeddinfarahnaz effectofpreheatingandprecoolingontheflexuralstrengthandmodulusofelasticityofnanohybridandsiloranebasedcomposite
AT motamedimehran effectofpreheatingandprecoolingontheflexuralstrengthandmodulusofelasticityofnanohybridandsiloranebasedcomposite
AT fattahzahra effectofpreheatingandprecoolingontheflexuralstrengthandmodulusofelasticityofnanohybridandsiloranebasedcomposite