Cargando…

Studies on enhancing operational stability of a reusable laccase-based biosensor probe for detection of ortho-substituted phenolic derivatives

An amperometric principle-based biosensor containing immobilized enzyme laccase from Trametes versicolor was developed for detection of ortho-substituted phenolic derivatives. Different immobilization methods for Trametes versicolor laccase enzyme on cellophane membrane and the enhancement of operat...

Descripción completa

Detalles Bibliográficos
Autores principales: Sarika, C., Rekha, K., Narasimha Murthy, B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4624137/
https://www.ncbi.nlm.nih.gov/pubmed/28324391
http://dx.doi.org/10.1007/s13205-015-0292-7
_version_ 1782397782430056448
author Sarika, C.
Rekha, K.
Narasimha Murthy, B.
author_facet Sarika, C.
Rekha, K.
Narasimha Murthy, B.
author_sort Sarika, C.
collection PubMed
description An amperometric principle-based biosensor containing immobilized enzyme laccase from Trametes versicolor was developed for detection of ortho-substituted phenolic derivatives. Different immobilization methods for Trametes versicolor laccase enzyme on cellophane membrane and the enhancement of operational stability of the immobilized enzyme electrode using various protein-based stabilizing agents were studied. Among tested methods of immobilization, co-cross-linking method with bovine serum albumin was superior to the other methods in terms of sensitivity, limit of detection, response time, and operating and thermal stability. Biosensor response reached steady state within 3 min and exhibited maximum activity at 45 °C and pH 6.8. The sensitivity of the ortho-substituted phenols for the test biosensor developed with co-cross-linking method of immobilization using bovine serum albumin as the protein-based stabilizing agent was in the order: 2-aminophenol > guaiacol(2-methoxyphenol) > catechol(2-hydroxyphenol) > cresol(2-methyl phenol) > 2-chlorophenol. Validation of the newly developed biosensor by comparison with HPLC showed good agreement in the results. A newly developed biosensor was applied for quantification of ortho-substituted phenols in simulated effluent samples.
format Online
Article
Text
id pubmed-4624137
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-46241372015-10-30 Studies on enhancing operational stability of a reusable laccase-based biosensor probe for detection of ortho-substituted phenolic derivatives Sarika, C. Rekha, K. Narasimha Murthy, B. 3 Biotech Original Article An amperometric principle-based biosensor containing immobilized enzyme laccase from Trametes versicolor was developed for detection of ortho-substituted phenolic derivatives. Different immobilization methods for Trametes versicolor laccase enzyme on cellophane membrane and the enhancement of operational stability of the immobilized enzyme electrode using various protein-based stabilizing agents were studied. Among tested methods of immobilization, co-cross-linking method with bovine serum albumin was superior to the other methods in terms of sensitivity, limit of detection, response time, and operating and thermal stability. Biosensor response reached steady state within 3 min and exhibited maximum activity at 45 °C and pH 6.8. The sensitivity of the ortho-substituted phenols for the test biosensor developed with co-cross-linking method of immobilization using bovine serum albumin as the protein-based stabilizing agent was in the order: 2-aminophenol > guaiacol(2-methoxyphenol) > catechol(2-hydroxyphenol) > cresol(2-methyl phenol) > 2-chlorophenol. Validation of the newly developed biosensor by comparison with HPLC showed good agreement in the results. A newly developed biosensor was applied for quantification of ortho-substituted phenols in simulated effluent samples. Springer Berlin Heidelberg 2015-03-10 2015-12 /pmc/articles/PMC4624137/ /pubmed/28324391 http://dx.doi.org/10.1007/s13205-015-0292-7 Text en © The Author(s) 2015 https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Article
Sarika, C.
Rekha, K.
Narasimha Murthy, B.
Studies on enhancing operational stability of a reusable laccase-based biosensor probe for detection of ortho-substituted phenolic derivatives
title Studies on enhancing operational stability of a reusable laccase-based biosensor probe for detection of ortho-substituted phenolic derivatives
title_full Studies on enhancing operational stability of a reusable laccase-based biosensor probe for detection of ortho-substituted phenolic derivatives
title_fullStr Studies on enhancing operational stability of a reusable laccase-based biosensor probe for detection of ortho-substituted phenolic derivatives
title_full_unstemmed Studies on enhancing operational stability of a reusable laccase-based biosensor probe for detection of ortho-substituted phenolic derivatives
title_short Studies on enhancing operational stability of a reusable laccase-based biosensor probe for detection of ortho-substituted phenolic derivatives
title_sort studies on enhancing operational stability of a reusable laccase-based biosensor probe for detection of ortho-substituted phenolic derivatives
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4624137/
https://www.ncbi.nlm.nih.gov/pubmed/28324391
http://dx.doi.org/10.1007/s13205-015-0292-7
work_keys_str_mv AT sarikac studiesonenhancingoperationalstabilityofareusablelaccasebasedbiosensorprobefordetectionoforthosubstitutedphenolicderivatives
AT rekhak studiesonenhancingoperationalstabilityofareusablelaccasebasedbiosensorprobefordetectionoforthosubstitutedphenolicderivatives
AT narasimhamurthyb studiesonenhancingoperationalstabilityofareusablelaccasebasedbiosensorprobefordetectionoforthosubstitutedphenolicderivatives