Cargando…
Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study
INTRODUCTION: Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to exa...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4624940/ https://www.ncbi.nlm.nih.gov/pubmed/26509265 http://dx.doi.org/10.1371/journal.pone.0140822 |
_version_ | 1782397895480180736 |
---|---|
author | Mentiplay, Benjamin F. Perraton, Luke G. Bower, Kelly J. Adair, Brooke Pua, Yong-Hao Williams, Gavin P. McGaw, Rebekah Clark, Ross A. |
author_facet | Mentiplay, Benjamin F. Perraton, Luke G. Bower, Kelly J. Adair, Brooke Pua, Yong-Hao Williams, Gavin P. McGaw, Rebekah Clark, Ross A. |
author_sort | Mentiplay, Benjamin F. |
collection | PubMed |
description | INTRODUCTION: Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. METHODS: 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. RESULTS: Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). CONCLUSIONS: Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations. |
format | Online Article Text |
id | pubmed-4624940 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-46249402015-11-06 Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study Mentiplay, Benjamin F. Perraton, Luke G. Bower, Kelly J. Adair, Brooke Pua, Yong-Hao Williams, Gavin P. McGaw, Rebekah Clark, Ross A. PLoS One Research Article INTRODUCTION: Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. METHODS: 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. RESULTS: Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). CONCLUSIONS: Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations. Public Library of Science 2015-10-28 /pmc/articles/PMC4624940/ /pubmed/26509265 http://dx.doi.org/10.1371/journal.pone.0140822 Text en © 2015 Mentiplay et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Mentiplay, Benjamin F. Perraton, Luke G. Bower, Kelly J. Adair, Brooke Pua, Yong-Hao Williams, Gavin P. McGaw, Rebekah Clark, Ross A. Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study |
title | Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study |
title_full | Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study |
title_fullStr | Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study |
title_full_unstemmed | Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study |
title_short | Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study |
title_sort | assessment of lower limb muscle strength and power using hand-held and fixed dynamometry: a reliability and validity study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4624940/ https://www.ncbi.nlm.nih.gov/pubmed/26509265 http://dx.doi.org/10.1371/journal.pone.0140822 |
work_keys_str_mv | AT mentiplaybenjaminf assessmentoflowerlimbmusclestrengthandpowerusinghandheldandfixeddynamometryareliabilityandvaliditystudy AT perratonlukeg assessmentoflowerlimbmusclestrengthandpowerusinghandheldandfixeddynamometryareliabilityandvaliditystudy AT bowerkellyj assessmentoflowerlimbmusclestrengthandpowerusinghandheldandfixeddynamometryareliabilityandvaliditystudy AT adairbrooke assessmentoflowerlimbmusclestrengthandpowerusinghandheldandfixeddynamometryareliabilityandvaliditystudy AT puayonghao assessmentoflowerlimbmusclestrengthandpowerusinghandheldandfixeddynamometryareliabilityandvaliditystudy AT williamsgavinp assessmentoflowerlimbmusclestrengthandpowerusinghandheldandfixeddynamometryareliabilityandvaliditystudy AT mcgawrebekah assessmentoflowerlimbmusclestrengthandpowerusinghandheldandfixeddynamometryareliabilityandvaliditystudy AT clarkrossa assessmentoflowerlimbmusclestrengthandpowerusinghandheldandfixeddynamometryareliabilityandvaliditystudy |